Prosense P-4834 | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   P-4834

PROSENSE P-4834
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

P-4834   
900.90

Range
Relays
IP66 Adaptor
No calibration port

   3 Weeks  ]
Trustworthy Certification

PROSENSE "P" Series fixed gas detectors are certified with ATEX/IECEx.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65 protection class.

Accurate Readings

Pellistor, Electrochemical, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

P Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off sensor in high gas concentration in order to properly secure the operational lifetime of Pellistor sensor.

Auto Analog Signal Monitoring

P Series detectors carefully check the analog output signal level continuously to match the measurement level before promptly transferred to the panel. P Series adjust the signal level in case of any deviation and generate fault signal when adjustment fails.

Universal Communication Protocols

  • 4-20mA Analog and Modbus RS485 RTU outputs are simple to operate efficiently.
  • P Series open-source Modbus codes support successful integration to SCADA systems.
  • P-3R+ relay module can be properly integrated into P Series detectors for extra operations.

Zero Suppression

Adjusting, the detector will show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Continuous Self-Test

The detectors check itself continuously if it operates perfectly or not and indicates a fault in case of any failure.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Process Industry
  • Water Treatment
  • Chemical Industry
  • Food and Medicine Facilities
  • Metal Industry
  • Gas Distribution Stations
  • Laboratories

Specifications P-XY34
Sensor Technology Electrochemical
Output Signal 44-20mA and Modbus RS485 RTU
Sensor Warm-Up Time 60sec
Response Time(T90) <30sec*
Accuracy %±1
Operating Temperature -40°C ~ +70°C
Humidity 5 ~ 95%RH
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 4W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 2 x 1/2''NPT
IP Rating IP65 / Optional IP66 (Sensor Head)
Junction Box Epoxy Painted Die-Cast Aluminum
Sensor Head 316L Stainless Steel
Dimensions/Weight 183x118,15x88mm / 1420gr
ATEX Marking II 2G Ex db IIC T5/T4 Gb
Hazardous Class Zone 1 or Zone 2
Certificates IMQ 19 ATEX 045 X
IECEx IMQ 18.0009X
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    13 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$100.98 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
RAE-600-0058-000-EQUIV
(2632)

PORTAGAS  RAE-600-0058-000-EQUIV

Calibration Gas Ammonia 50ppm Balance Nitrogen 58 Liter GAL Cylinder (Made by Portagas)

Configure

$252.43 
SCOTT-077-0207-EQUIV
(2430)

PORTAGAS  SCOTT-077-0207-EQUIV

Calibration Gas Ammonia 500ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
CYL-10005003
(297)

PORTAGAS  CYL-10005003

Calibration Gas Ammonia (NH3) 50 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
SP-P-TB04
(7037)

PROSENSE  SP-P-TB04

Prosense P Transmitter/Main Board for P series gas detectors



$462.00 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> AMMONIA :    42 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$690.96 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
51001AL-0-1015/0300P/L0
(7123)

RC SYSTEMS  51001AL-0-1015/0300P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 