MRU SWG 100 CEM Stationary Continuous Emissions Analyzer for CEMS applications for measurement of Oxygen (O2) 0-25%, Carbon monoxide (CO)0-10000ppm, Carbon Dixide (CO2) 0-40%, Nitric oxide (NO) 0-4000ppm, Nitrogen Dioxide (NO) 0-1000ppm or Sulfur dioxide (SO2) 0-4000ppm with NDIR and electrochemical cells. 4x4-20 mA, 2 alarm relays and RS485 Modbus. IP54.RELAYS MODBUS
951055
Please Email us your request for quote
Oxygen Sensor
_____-None 65419-Long life electrochemical cell for O2 analysis (0 to 25%) 11744-Paramagnetic cell for O2 analysis (0 to 25%)
CO Sensor
_____-None 65990-CO electrochemical cell measurement (0 to 4,000 / 10,000ppm) 65968-CO electrochemical cell measurement (0 to 4,000 / 20,000ppm)
NO Sensor
_____-None 65989-NO electrochemical cell measurement (0 to 1,000 / 5,000ppm)
NO2 Sensor
_____-None 65989-NO2 electrochemical cell measurement (0 to 200 / 1,000ppm)
requires heated sampling line and sample gas cooler
SO2 Sensor
_____-None 65991-SO2 electrochemical cell measurement (0 to 1,000 / 4,000ppm)
requires heated sampling line and sample gas cooler
NDIR Sensor CO2/HC
_____-None 65684-CO2 analysis NDIR bench (0 to 40%) 12449-Triple gas NDIR: CO (0 to 1..10%), CO2 (0 to 40.0%), CxHy (0 to 1...4%) (*) 12448-Triple gas NDIR: CO (0 to 1000...30000ppm), CO2 (0 to 40%), CxHy (0 1000...20000ppm) 12450-Triple gas NDIR: CO (0 1000...30000ppm), CO2 (0 to 40%), CxHy (0 1000...10000ppm)(*) 12584-Triple gas NDIR: CO (0 1000...30000ppm), CO2 (0 to 40%), SO2 (0 to 1000...3000)(*)
NO2 and SO2 measurement requires use of heated sampling line
Cabinet Heater 200W
_____-None 66009-Cabinet 200W heater, temp regulated, for freeze protection 120 VAC 65771-Cabinet 200W heater, temp regulated, for freeze protection 230 VAC
For use in safe area only
Data Transfer
_____-None 65430R1-Remote Data Transfer Module 1 Sampling Point 65430R2-Remote Data Transfer Module 2 Sampling Points 65430R3-Remote Data Transfer Module 3 Sampling Points 65430R4-Remote Data Transfer Module 4 Sampling Points 65430R5-Remote Data Transfer Module 5 Sampling Points
I/O Module with 4 channel 4-20 mA analog output and 2 alarm relays (fail-safe NO contacts) includes remote sampling point switching control via 4x contacts and 4 channel analog input 4-20mA
Networking
_____-Modbus RS485 RTU 66029-Profibus Converter + Modbus RS485 RTU 66030-EthernetIP Converter + Modbus RS485 RTU
Flow Monitor
_______-None 8700111-1 DF252 flow volume monitoring system 1 sample point 8700112-2 DF252 flow volume monitoring system 2 sample points 8700113-3 DF252 flow volume monitoring system 3 sample points 8700114-4 DF252 flow volume monitoring system 4 sample points 8700115-5 DF252 flow volume monitoring system 5 sample points
3 to 30 m/sec flow velocity, for stacks with up to 300°C stack gas temperature
Unheated Sampling Line
_______-None 12604011-Unheated sampling line for each gas sampling probe 1 meter/1 probe 12604012-Unheated sampling line for each gas sampling probe 2 meter/2 probes 12604013-Unheated sampling line for each gas sampling probe 3 meter/3 probes 12604014-Unheated sampling line for each gas sampling probe 4 meter/4 probes 12604015-Unheated sampling line for each gas sampling probe 5 meter/5 probes
Teflon (PTFE) DN4/6mm
Gas Sampling Probes
_______-None 62592C1-19.68" (500mm )stainless steel tube, incl. 7" sintered filter max 932°F (1 Probe) 62592C2-19.68" (500mm )stainless steel tube, incl. 7" sintered filter max 932°F (2 Probes) 62592C3-19.68" (500mm )stainless steel tube, incl. 7" sintered filter max 932°F (3 Probes) 62592C4-19.68" (500mm )stainless steel tube, incl. 7" sintered filter max 932°F (4 Probes) 62592C5-19.68" (500mm )stainless steel tube, incl. 7" sintered filter max 932°F (5 Probes)
Gas sampling probe model LD for low dust with on tip sintered metal filter
Heated Sampling Line
_______-None 1259803-Heated gas sampling line for probe LD with 3m length/1 probe 1259806-Heated gas sampling line for probe LD with 6m length/2 probes 1259809-Heated gas sampling line for probe LD with 09m length/3 probes 1259812-Heated gas sampling line for probe LD with 12m length/4 probes 1259815-Heated gas sampling line for probe LD with 15m length/5 probes
Teflon (PTFE) DN4/6mm
Heated Sampling Line Extension
_______-None 1259810-Heated gas sampling line 10 meters extention 1259820-Heated gas sampling line 20 meters extention 1259830-Heated gas sampling line 30 meters extention 1259840-Heated gas sampling line 40 meters extention 1259850-Heated gas sampling line 50 meters extention
Gas sampling probe HD-GW
_______-None 61558F1-1 Gas sampling probe for flue gas with soot heated by analyzer temp regulator 61558F2-2 Gas sampling probe for flue gas with soot heated by analyzer temp regulator 61558F3-3 Gas sampling probe for flue gas with soot heated by analyzer temp regulator 61558F4-4 Gas sampling probe for flue gas with soot heated by analyzer temp regulator 61558F5-5 Gas sampling probe for flue gas with soot heated by analyzer temp regulator 61558S1-1 Gas sampling probe for flue gas with soot heated by probes thermostat 61558S2-2 Gas sampling probe for flue gas with soot heated by probes thermostat 61558S3-3 Gas sampling probe for flue gas with soot heated by probes thermostat 61558S4-4 Gas sampling probe for flue gas with soot heated by probes thermostat 61558S5-5 Gas sampling probe for flue gas with soot heated by probes thermostat