Honeywell Spxcdulnb1 | Carbon Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   SPXCDULNB1

HONEYWELL SPXCDULNB1
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XCD Sensepoint Gas Detector, Carbon Dioxide (CO2) Infrared Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for carbon dioxide (CO2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 2%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

SPXCDULNB1   
1,731.84

Modbus RTU
Enclosure
Agency Approval
Entry
Sunshade/Deluge Protection
Custom Tag

   5 Weeks  ]



XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
FEATURES

One-Stop Shop
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  • Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • SurecellTM electrochemical sensors
  • Reflex® sensor health check
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective
  • Common transmitter platform
  • Minimal training required
  • Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings
Simple Installation
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  • 2 x M20 or 3⁄4” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  • Remote sensor gassing kit
  • Duct mounting kit
  • Calibration gas flow housing
  • Collecting cone

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and Reflex® sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

  • Industrial manufacturing facilities
  • Power plants
  • Waste water facilities
  • Utilities
  • Food and beverage production
  • Refineries and chemical plants
  • Onshore oil and gas terminals
  • Production platforms
  • Exploration and drilling
Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

Specifications
Gas Carbon Dioxide
Sensor Family mV
User Selectable Full Scale Range 2%Vol. only
Default Range 2%Vol.
Steps n/a
User Selectable Cal Gas Range 30 to 70% of selected full scale range
Default Cal Point 1%Vol.
Response Time (T90) Secs <30
Accuracy <+/-0.04%Vol.
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 50°C / 122°F
Default Alarm Point A1 0.4%Vol. ▲
Default Alarm Point A2 0.8%Vol. ▲

General Transmitter Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries UL\cUL versions: 2 x ¾"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992

Certification
US, Latin America, Canada UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number

Honeywell Sensepoint XCD Option Matrix

Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
SPXCDMTBR
(670)

HONEYWELL  SPXCDMTBR

Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets



$104.72 
S3KCAL
(667)

HONEYWELL  S3KCAL

Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors.



$117.16 
(668)

HONEYWELL  SPXCDCC

Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors.



$119.23 
CYL-90302169
(1273)

PORTAGAS  CYL-90302169

Calibration Gas Carbon Dioxide (CO2) 1000 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10046000
(876)

PORTAGAS  CYL-10046000

Calibration Gas Carbon Dioxide (CO2) 25,000 ppm 2.5% Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90092236
(875)

PORTAGAS  CYL-90092236

Calibration Gas Carbon Dioxide (CO2) 10,000 ppm 1% Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
SPXCDSDP
(671)

HONEYWELL  SPXCDSDP

Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors.



$402.28 
SPXCDDMK
(669)

HONEYWELL  SPXCDDMK

Duct mounting kit for Honeywell Sensepoint XCD Sensors.



$443.75 
SPXCDXSB1SS
(676)

HONEYWELL  SPXCDXSB1SS

Replacement Sensor Cartridge for Carbon Dioxide (CO2) IR (Infrared) XCD Detector 0-2.00%VOL



$998.30 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

> CARBON DIOXIDE :    27 Items found.
I-M308WV
(2955)

INTEC  I-M308WV

Intec Controls I-M308 Infrared (NDIR) Gas Transmitter for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-(5)10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm) and 24 VAC/VDC powered.

Configure

$166.68 
I-M350WV-R000
(2956)

INTEC  I-M350WV-R000

Intec Controls I-M350 Infrared (NDIR) Gas Transmitter and Control System for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm). Optional relay/ouput control, audible alarm, LCD Display and relative humidity measurement.

Configure

$191.88 
SAN-10
(7050)

CO2METER  SAN-10

CO2Meter SAN-10 Personal Safety Monitor for Carbon Dioxide (CO2) 0-5% with NDIR sensor. Visual strobe light, audible and vibrating alarmas. Includes rechargeable Li-Ion battery, 110/240 VAC USB Wall Adapter and LCD Display. IP54 rubber enclosure.



$383.04 
CD-6MC
(4482)

MACURCO  CD-6MC

MACURCO CD-6 low voltage Carbon Dioxide (CO2) 0-5000ppm Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$495.09 
CD-6G
(6828)

MACURCO  CD-6G

MACURCO CD-6G / CD-6B Greenhouse Carbon Dioxide (CO2) 0-5% vol Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. Auto or Manual Calibration (Relays, 4-20mA output). ETL Listed to UL 61010-1.

Configure

$495.09 
CD-12MC
(4494)

MACURCO  CD-12MC

MACURCO CD-12 line voltage Gas Detector, controller and transducer for Carbon Dioxide (CO2) 0-5000ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$515.08 
RAD-0102-6
(7048)

CO2METER  RAD-0102-6

CO2Meter RAD-0102-6 Remote "CO2 Storage Safety 3" gas leak detector with local and remote displays for Carbon Dioxide (CO2) 0-5% (0-50,000 ppm) with NDIR sensor. Includes audible and visual alarms, 3 alarm relays, 4-20 mA output and LCD display. IP54 Enclosure. UL Listed, meets NFPA, IFC, and NBIC requirements, OSHA and NIOSH TWA standards. Alarms 5,000 TWA, 1.5% (user configurable), 3% (user configurable), sensor life > 15 years, 12-24VDC power, includes 110-220VAC multi-region power adapter.

Configure

$672.00 
364-510-01
(6148)

DELPHIAN  364-510-01

Delphian GazTell Fixed Point Infrared Gas Detector for Carbon Dioxide (CO2) 0.02% to 4.5% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7133
(6786)

PROSENSE  P-7133

Prosense P-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with range 0-5000ppm or 0-5% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$823.68 
PQN-7133-1/2
(6959)

PROSENSE  PQN-7133-1/2

Prosense PQN-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,003.86 
PQD-7133-1/2
(6747)

PROSENSE  PQD-7133-1/2

Prosense PQD-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
1400ALD-101032/015P-L0
(6906)

RC SYSTEMS  1400ALD-101032/015P-L0

RC Systems SenSmart 1400 gas detector for Carbon Dioxide (C02) 0-1.5% or 0-5% with 'ST-48' smart transmitter. IR sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,432.47 
100-0008-SS/100-0015-CO2
(4752)

ESP SAFETY  100-0008-SS/100-0015-CO2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Carbon Dioxide (CO2) 0-2% vol, 0-5% vol or 0-3000ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
GG-CO2-1
(2964)

CALIBRATION TECHNOLOGIES  GG-CO2-1

CTI GasGuard CO2 Carbon Dioxide Infrared Sensor (0-1%, 0-3% and 0-5%) for gas leak detection in wineries, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,519.00 
CM-900
(7201)

CO2METER  CM-900

CO2Meter CM-900 Industrial Gas Detector with NDIR (Infrared) sensor for Carbon Dioxide (CO2) 0-50,000ppm for Harsh Environments. Includes 3 configurable alarms, 3 dry contact relays, 4-20mA output and backup battery. 9-32VDC. Aluminum enclosure. IP64.

Configure

$1,535.04 
54001AL-0-9053/005P/L0
(7119)

RC SYSTEMS  54001AL-0-9053/005P/L0

RC Systems SenSmart 5400 3-wire gas detector for Carbon Dioxide (CO2) 0-1.5% or 0-5% with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
IR-F9-CO2-1-COM
(1547)

HONEYWELL  IR-F9-CO2-1-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Carbon Dioxide (CO2) with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

Configure

$2,001.73 
967-425520-100
(6068)

DETCON  967-425520-100

Detcon IR-700-CO2 Infrared (NDIR) non-intrusive Smart Sensor for Carbon Dioxide (CO2) 10-100%. Includes LED display, 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

34001AL-0-9053/005P/L0
(6897)

RC SYSTEMS  34001AL-0-9053/005P/L0

RC Systems SenSmart 3400 3 wire gas detector for Carbon Dioxide (CO2) 0-1.5% or 0-5% with 'ST-48' smart transmitter with infrared (IR) sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
967-405520-005
(6067)

DETCON  967-405520-005

Detcon IR-700-CO2 Infrared (NDIR) non-intrusive Smart Sensor for Carbon Dioxide (CO2) 0-5%. Includes LED display, 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.