Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (6543)

DEGA  0407208

$943.29     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



DEGA 0407208 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

DEGA NS II LCD RE Gas Detector with Infrared Sensor for Ethylen Oxide (C2H4O) with range 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Part# with Options:        0407208
Price with Options:        943.29

Options:    

IP66
(1) IP66 Ingress protection with water cap for Dega NS II/NS III
M20 to NPT Adaptor
(2) M20 to NPT adaptor for Dega Zone 1 and Zone 2 detectors

  Availability 4 Weeks  ]

DEGA NS II LCD RE detector is a part of the gas detection system. Detector is located in monitored premises in which critical situations due to accumulation of flammable or toxic substances can occur. Detector converts the measured concentration of substances into a unified signal 4 - 20mA and RS485. The detector has an LCD display to show measured concentrations of detected substances in real time, and it is equipped with 4 relays.

The detector can be connected to control panels DEGA UPA III, DEGA UKA III and DEGA UDA III.

  • Detection types: catalytic, electrochemical, infrared, photoionization (PID)
  • Detection of toxic and combustible gases and oxygen
  • For explosive environments ATEX zone 2
  • Protection level IP54/IP66 (with protection cover)
  • Produced in compliance with standard SIL

Dega general purpose gas detector transmitter

TECHNICAL SPECIFICATION:
Power supply8-28 V DC
Output:4 - 20 mA, RS485, Modbus
Cover protection levelIP 54, with water protection cover DEGA WATER CAP IP66
Input:1,2 W
Specification in compliance with ATEX:II 3 G Ex db ic ec nC IIC T5/4 Gc Tamb: 0°C- +40°C
Placement:BE3N2 – areas with danger of explosion, zone 2
Dimensions(WxHxD):140 x 140 x 70 mm
Weight0,7 kg
Sensor technology:catalytic, electrochemical, infrared, photoionization
Estimated life of sensor in clean environment:catalytic (1-2 years),electrochemical (1-3 years), infrared (minimum 5 years), photoionization (1 year)
Relative humidity of the ambient air:max. 95%
Export Info
Made inCzechia
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES & PARTS > DEGA
    0212179 DEGA GAS INLET, calibration adapter/cup for DEGA NS II and DEGA NS III ..

  • ACCESSORIES & PARTS > DEGA
    1387 DEGA Water Cap/Splash Guard for DEGA NS II and DEGA NS III ..

  • CALIBRATION KITS GDS > ETHYLENE OXIDE
    1200-0772 GDS Gas Detector Calibration Gas Kit Ethylene Oxide (ETO) 50% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16 OR 32 CHANNEL
    0302092 DEGA UPA III Gas Detection Controller/Alarm Panel for 8 4-20mA analog gas detectors and up to 32 Dega gas detectors over RS-485. Dega/Modbus RS-485 Modbus Host port. 10 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for ..

  • MULTI-POINT CONTROLLERS > 4 OR 8-CHANNEL
    0301036 DEGA UKA III Gas Detection Controller/Alarm Panel for up to 8 Dega gas detectors over RS-485. 5 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for emergency solenoid valve and 1 4-20mA control output. IP54. ..

  • SOFTWARE > DEGA
    0901010 DegaConfig Software for configuration and remote detector support, custom settings and real-time monitoring of DEGA Alarm Panels and Gas Detectors, detector configuration and alarm relays via RS-485, controller detector configuration, relay cause and eff ..

  • WEATHERPROOF > TEXT ALARM ANNUNCIATORS
    0603015 DEGA PANEL S1 III ultra-thin LED backlit fixed custom text alarm annunciator, text is visible when active only, IP54, 24VDC, 506x206x38 mm ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ETHYLENE OXIDE :    18 Items found.
M001-0012-000
(5997)

MPOWER  M001-0012-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ethylene Oxide (ETO) 0-100ppm or 0-200ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$298.00 
0401074
(6486)

DEGA  0401074

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Ethylene oxide (C2H4O) with range 0-10ppm. 4-20mA 3-Wire and RS-485 outputs. IP54.



$420.33 
0402081
(6518)

DEGA  0402081

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Ethylene Oxide (C2H4O) with range 0-10ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$439.88 
0401112
(6497)

DEGA  0401112

DEGA NB III Gas Detection Transmitter with Infrared Sensor for Ethylene Oxide (C2H4O) with range 0-100% LEL. 4-20mA 3-Wire and RS-485 outputs. IP54.



$493.64 
0407207
(6542)

DEGA  0407207

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Ethylene Oxide (C2H4O) with range 0-10ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$498.53 
G02-BJ10-100
(3027)

RAE  G02-BJ10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Ethylene Oxide (EtO) 0-100 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
0019-7063
(4018)

BACHARACH  0019-7063

Bacharach Leakator 10 Combustible Gas Leak Detector for Ethylene Oxide (ETO). Includes carrying case, gas sensor, flexible probe, and instruction manual. Low maintenance and Easy to use. Up to 30 hours of continuos operation. ABS Housing. CE Mark and UL approved for Class 1 Div 1 Groups A, B, C and D.



 
BWS_-E-Y
(6386)

BW  BWS-E-Y

BW Solo Serviceable Single-gas Detector for Ethylene oxide (ETO) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$548.25 
364-455-02-365-710-11
(6152)

DELPHIAN  364-455-02-365-710-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ethylene Oxide (ETO) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$700.80 
GM/EC-01-22-05
(134)

GDS  GM/EC-01-22-05

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
GMII-01-022-05/00-000-00/0-0
(146)

GDS  GMII-01-022-05/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
961-EJ0026-100G
(6358)

DETCON  961-EJ0026-100G

Detcon DM-100-C2H4O Electrochemical Ethylene Oxide (C2H4O) 0-100ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-12EJ90-100
(6082)

DETCON  967-12EJ90-100

Detcon DM-700-C2H4O Electrochemical "Smart" Ethylene Oxide (C2H4O) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

GDS-IR-1-127-1
(1741)

GDS  GDS-IR-1-127-1

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Ethylene Oxide (ETO) with range 0-50% LEL (0-1.5% Vol), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP).

Configure

$1,890.00 
GM/ECx-01-22-05-1-0900
(1820)

GDS  GM/ECx-01-22-05-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (XP, IS) configured for Ethylene Oxide (C2H4O) with range 0-50 to 0-200 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-22-05/00-00-00/0
(3296)

GDS  GMCX-01-22-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-01-022-05/00-000-00/1-0900
(1843)

GDS  GMIIx-01-022-05/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head configured for Ethylene Oxide (C2H4O) with range 0-50 to 0-200 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-22-05/00-00-00/1-0900
(3432)

GDS  GM/TX/01-22-05/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Ethylene Oxide EtO (C2H4O) with range 0-50 to 0-200 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00