Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (6534)

DEGA  0407159

$498.53     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



DEGA 0407159 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Hydrogen Bromide (HBr) with range 0-20ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Part# with Options:        0407159
Price with Options:        498.53

Options:    

IP66
(1) IP66 Ingress protection with water cap for Dega NS II/NS III
M20 to NPT Adaptor
(2) M20 to NPT adaptor for Dega Zone 1 and Zone 2 detectors

  Availability 4 Weeks  ]

DEGA NS II LCD RE detector is a part of the gas detection system. Detector is located in monitored premises in which critical situations due to accumulation of flammable or toxic substances can occur. Detector converts the measured concentration of substances into a unified signal 4 - 20mA and RS485. The detector has an LCD display to show measured concentrations of detected substances in real time, and it is equipped with 4 relays.

The detector can be connected to control panels DEGA UPA III, DEGA UKA III and DEGA UDA III.

  • Detection types: catalytic, electrochemical, infrared, photoionization (PID)
  • Detection of toxic and combustible gases and oxygen
  • For explosive environments ATEX zone 2
  • Protection level IP54/IP66 (with protection cover)
  • Produced in compliance with standard SIL

Dega general purpose gas detector transmitter

TECHNICAL SPECIFICATION:
Power supply8-28 V DC
Output:4 - 20 mA, RS485, Modbus
Cover protection levelIP 54, with water protection cover DEGA WATER CAP IP66
Input:1,2 W
Specification in compliance with ATEX:II 3 G Ex db ic ec nC IIC T5/4 Gc Tamb: 0°C- +40°C
Placement:BE3N2 – areas with danger of explosion, zone 2
Dimensions(WxHxD):140 x 140 x 70 mm
Weight0,7 kg
Sensor technology:catalytic, electrochemical, infrared, photoionization
Estimated life of sensor in clean environment:catalytic (1-2 years),electrochemical (1-3 years), infrared (minimum 5 years), photoionization (1 year)
Relative humidity of the ambient air:max. 95%
Export Info
Made inCzechia
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES & PARTS > DEGA
    0212179 DEGA GAS INLET, calibration adapter/cup for DEGA NS II and DEGA NS III ..

  • ACCESSORIES & PARTS > DEGA
    1387 DEGA Water Cap/Splash Guard for DEGA NS II and DEGA NS III ..

  • MULTI-POINT CONTROLLERS > 16 OR 32 CHANNEL
    0302092 DEGA UPA III Gas Detection Controller/Alarm Panel for 8 4-20mA analog gas detectors and up to 32 Dega gas detectors over RS-485. Dega/Modbus RS-485 Modbus Host port. 10 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for ..

  • MULTI-POINT CONTROLLERS > 4 OR 8-CHANNEL
    0301036 DEGA UKA III Gas Detection Controller/Alarm Panel for up to 8 Dega gas detectors over RS-485. 5 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for emergency solenoid valve and 1 4-20mA control output. IP54. ..

  • SOFTWARE > DEGA
    0901010 DegaConfig Software for configuration and remote detector support, custom settings and real-time monitoring of DEGA Alarm Panels and Gas Detectors, detector configuration and alarm relays via RS-485, controller detector configuration, relay cause and eff ..

  • WEATHERPROOF > TEXT ALARM ANNUNCIATORS
    0603015 DEGA PANEL S1 III ultra-thin LED backlit fixed custom text alarm annunciator, text is visible when active only, IP54, 24VDC, 506x206x38 mm ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HYDROGEN BROMIDE :    5 Items found.
0402201
(6529)

DEGA  0402201

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Hydrogen Bromide (HBr) with range 0-20ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$439.88 
0402123
(6501)

DEGA  0402123

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Hydrogen Bromide (HBR) with range 0-20ppm. 4-20mA 3-Wire and RS-485 outputs. IP54.



$493.64 
961-080026-030G
(6364)

DETCON  961-080026-030G

Detcon DM-100-HBr Electrochemical Hydrogen Bromide (HBr) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

EX-HBR-30P-O
(6025)

MACURCO  EX-HBR-30P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Bromide (HBR) 0-30ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,613.47 
967-090890-030
(6089)

DETCON  967-090890-030

Detcon DM-700-HBr Electrochemical "Smart" Hydrogen Bromide (HBr) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.