Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (6526)

DEGA  0402105

$909.08     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



DEGA 0402105 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

DEGA NS II Gas Detection Transmitter with Infrared Sensor for Carbon Dioxide (CO2) with range 0-5%. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Part# with Options:        0402105
Price with Options:        909.08

Options:    

IP66
(1) IP66 Ingress protection with water cap for Dega NS II/NS III
M20 to NPT Adaptor
(2) M20 to NPT adaptor for Dega Zone 1 and Zone 2 detectors

  Availability 4 Weeks  ]

DEGA NS II transmitter is a part of the gas detection system. Transmitter is located in monitored premises in which critical situations due to accumulation of flammable or toxic substances can occur. Detector converts the measured concentration of substances into a unified signal 4 - 20mA and RS485.

The transmitter can be connected to control panels DEGA UPA III, DEGA UKA III and DEGA UDA III.

  • Detection types: catalytic, electrochemical, infrared, photoionization (PID)
  • Detection of toxic and combustible gases and oxygen
  • For explosive environments ATEX zone 2
  • Protection level IP54/IP66 (with protection cover)
  • Produced in compliance with standard SIL

Dega general purpose gas detector transmitter

TECHNICAL SPECIFICATION:
Power supply8-28 V DC
Output:4 - 20 mA, RS485, Modbus
Cover protection levelIP 54, with water protection cover DEGA WATER CAP IP66
Input:1,2 W
Placement:BE3N2 – areas with danger of explosion, zone 2
Dimensions(WxHxD):140 x 140 x 70 mm
Weight0,7 kg
Sensor technology:catalytic, electrochemical, infrared, photoionization
Estimated life of sensor in clean environment:catalytic (1-2 years),electrochemical (1-3 years), infrared (minimum 5 years), photoionization (1 year)
Relative humidity of the ambient air:max. 95%
Export Info
Made inCzechia
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES & PARTS > DEGA
    0212179 DEGA GAS INLET, calibration adapter/cup for DEGA NS II and DEGA NS III ..

  • ACCESSORIES & PARTS > DEGA
    1387 DEGA Water Cap/Splash Guard for DEGA NS II and DEGA NS III ..

  • CALIBRATION GAS > CARBON DIOXIDE
    CYL-10044500 Calibration Gas Carbon Dioxide (CO2) 25,000 ppm 2.5% Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • MULTI-POINT CONTROLLERS > 16 OR 32 CHANNEL
    0302092 DEGA UPA III Gas Detection Controller/Alarm Panel for 8 4-20mA analog gas detectors and up to 32 Dega gas detectors over RS-485. Dega/Modbus RS-485 Modbus Host port. 10 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for ..

  • MULTI-POINT CONTROLLERS > 4 OR 8-CHANNEL
    0301036 DEGA UKA III Gas Detection Controller/Alarm Panel for up to 8 Dega gas detectors over RS-485. 5 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for emergency solenoid valve and 1 4-20mA control output. IP54. ..

  • SOFTWARE > DEGA
    0901010 DegaConfig Software for configuration and remote detector support, custom settings and real-time monitoring of DEGA Alarm Panels and Gas Detectors, detector configuration and alarm relays via RS-485, controller detector configuration, relay cause and eff ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CARBON DIOXIDE :    43 Items found.
I-M308WV
(2955)

INTEC  I-M308WV

Intec Controls I-M308 Infrared (NDIR) Gas Transmitter for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-(5)10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm) and 24 VAC/VDC powered.

Configure

$129.90 
I-M350WV-R000
(2956)

INTEC  I-M350WV-R000

Intec Controls I-M350 Infrared (NDIR) Gas Transmitter and Control System for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm). Optional relay/ouput control, audible alarm, LCD Display and relative humidity measurement.

Configure

$146.22 
AZ-0001
(1493)

CO2METER  AZ-0001

CO2Meter pSense Portable Detector for Carbon Dioxide (C02) 0-2000 ppm with power supply. Temperature and Humidity Meter. 80dB audible alarm. 120-220 VAC Adapter. Includes 4 AA Bateries, ABS Plastic Case and Manual.



$274.80 
ESENSE-LEED
(920)

CO2METER  ESENSE-LEED

CO2Meter eSense FAI Wall-Mounted Carbon Dioxide (CO2) Alarm for LEED with Power Supply. Includes audible alarm and flashing light. 4-20mA Ouptut.



$298.94 
AZ-0018
(1494)

CO2METER  AZ-0018

CO2Meter pSense Portable Detector for Carbon Dioxide (C02) 0-2000 ppm with Data Logger Kit and Power Supply. Temperature and Humidity Meter. 80dB audible alarm. 120-220 VAC Adapter. Includes 4 AA Bateries, ABS Plastic Case and Manual.



$334.80 
ESENSE-PROGRAMMABLE
(923)

CO2METER  ESENSE-PROGRAMMABLE

CO2Meter eSense Programmable Wall-Mounted Carbon Dioxide (CO2) Alarm with Power Supply. Customizable 0-10V (0-3000 ppm) analog output.



$344.94 
CD-6H
(4482)

MACURCO  CD-6H

MACURCO CD-6 low voltage Carbon Dioxide (CO2) 0-5000ppm Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$348.49 
CD-12H
(4494)

MACURCO  CD-12H

MACURCO CD-12 line voltage Gas Detector, controller and transducer for Carbon Dioxide (CO2) 0-5000ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$365.92 
ESENSE-PROGRAMMABLE-CABLE
(922)

CO2METER  ESENSE-PROGRAMMABLE-CABLE

CO2Meter eSense Programmable Wall-Mounted Carbon Dioxide (CO2) Alarm with Power Supply and Program Cable. Customizable 0-10V (0-3000 ppm) analog output.



$379.44 
AZ-0002
(1495)

CO2METER  AZ-0002

CO2Meter pSense High Accuracy (±30 ppm) Portable Detector for Carbon Dioxide (C02) 0-5000 ppm with power supply. Temperature and Humidity Meter. 80dB audible alarm. 120-220 VAC Adapter. Includes 4 AA Bateries, ABS Plastic Case and Manual.



$418.80 
6302-0090
(6239)

BACHARACH  6302-0090

Bacharach MGS-410 Gas Detector Transmitter with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$445.50 
AZ-0002-DL
(1496)

CO2METER  AZ-0002-DL

CO2Meter pSense High Accuracy (±30 ppm) Portable Detector for Carbon Dioxide (C02) 0-5000 ppm with Data Logger Kit and Power Supply. Temperature and Humidity Meter. 80dB audible alarm. 120-220 VAC Adapter. Includes 4 AA Bateries, ABS Plastic Case and Manual.



$478.80 
6302-1090
(6249)

BACHARACH  6302-1090

Bacharach MGS-450 Gas Detector Transmitter with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600 or R290. Mobile App Bluetooth Interface.

Configure

$481.50 
0401080
(6491)

DEGA  0401080

DEGA NB III Gas Detection Transmitter with Infrared Sensor for Carbon Dioxide (CO2) with range 0-5% or 0-100% (High Concentration). 4-20mA 3-Wire and RS-485 outputs. IP54.

Configure

$518.08 
6302-4090
(6259)

BACHARACH  6302-4090

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$603.00 
364-510-01
(6148)

DELPHIAN  364-510-01

Delphian GazTell Fixed Point Infrared Gas Detector for Carbon Dioxide (CO2) 0.02% to 4.5% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$758.40 
G02-0007-000
(4126)

RAE  G02-0007-000

ToxiRAE Pro PGM-1850 Personal Portable Monitor For Carbon Dioxide (CO2) 0-50000 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. Not for hazardous areas. IP-65. Wireless-capable option.

Configure

$824.60 
6600-8010
(6267)

BACHARACH  6600-8010

Bacharach MGS-550 Industrial Refrigerant Gas Detector with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

Configure

$832.50 
0407219
(6546)

DEGA  0407219

DEGA NS II LCD RE Gas Detector with Infrared Sensor for Carbon Dioxide (CO2) with range 0-5%. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$967.73 
GG-CO2-1
(2964)

CALIBRATION TECHNOLOGIES  GG-CO2-1

CTI GasGuard CO2 Carbon Dioxide Infrared Sensor (0-1%, 0-3% and 0-5%) for gas leak detection in wineries, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,044.00 
Page: 1 | 2 | 3 | All