Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (6519)

DEGA  30100037

$783.36     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



DEGA 30100037 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-50ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Part# with Options:        30100037
Price with Options:        783.36

Options:    

Outputs
(1) Analog and Relay Outputs for Dega NS II
4-20mA option uses 30200001 internal board, 3 Alarm relay uses 30200003 internal board.
IP66
(2) IP66 Ingress protection with water cap for Dega NS II/NS III
M20 to NPT Adaptor
(3) M20 to NPT adaptor for Dega Zone 1 and Zone 2 detectors

  Availability 4 Weeks  ]

DEGA NS II transmitter is a part of the gas detection system. Transmitter is located in monitored premises in which critical situations due to accumulation of flammable or toxic substances can occur. Detector converts the measured concentration of substances into a unified signal 4 - 20mA and RS485.

The transmitter can be connected to control panels DEGA UPA III, DEGA UKA III and DEGA UDA III.

  • Detection types: catalytic, electrochemical, infrared, photoionization (PID)
  • Detection of toxic and combustible gases and oxygen
  • For explosive environments ATEX zone 2
  • Protection level IP54/IP66 (with protection cover)
  • Produced in compliance with standard SIL

Dega general purpose gas detector transmitter

TECHNICAL SPECIFICATION:
Power supply8-28 V DC
Output:4 - 20 mA, RS485, Modbus
Cover protection levelIP 54, with water protection cover DEGA WATER CAP IP66
Input:1,2 W
Placement:BE3N2 – areas with danger of explosion, zone 2
Dimensions(WxHxD):140 x 140 x 70 mm
Weight0,7 kg
Sensor technology:catalytic, electrochemical, infrared, photoionization
Estimated life of sensor in clean environment:catalytic (1-2 years),electrochemical (1-3 years), infrared (minimum 5 years), photoionization (1 year)
Relative humidity of the ambient air:max. 95%
Export Info
Made inCzechia
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES & PARTS > DEGA
    30300006 DEGA GAS INLET, calibration adapter/cup for DEGA NS II and DEGA NS III ..

  • ACCESSORIES & PARTS > DEGA
    30300008 DEGA Water Cap/Splash Guard for DEGA NS II and DEGA NS III ..

  • CALIBRATION GAS > HYDROGEN CYANIDE
    CYL-10320254 Calibration Gas Hydrogen Cyanide (HCN) 10 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas) ..

  • MULTI-POINT CONTROLLERS > 16 OR 32 CHANNEL
    10100003 DEGA UPA III Gas Detection Controller/Alarm Panel for 8 x 4-20mA analog gas detectors and up to 40 Dega gas detectors over RS-485. Dega/Modbus RS-485 Modbus Host port. 10 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output fo ..

  • MULTI-POINT CONTROLLERS > 4 OR 8-CHANNEL
    10100001 DEGA UKA III Gas Detection Controller/Alarm Panel for up to 8 Dega gas detectors over RS-485. USB, 2 Relay and 2 Optical and Acoustic Signalisation Outputs. Includes RS485 BUS, External Button, DEGA TcII and DEGA ZcII. IP54. ..

  • SOFTWARE > DEGA
    0901010 DegaConfig Software for configuration and remote detector support, custom settings and real-time monitoring of DEGA Alarm Panels and Gas Detectors, detector configuration and alarm relays via RS-485, controller detector configuration, relay cause and eff ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HYDROGEN CYANIDE :    21 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
BWS_-Z-Y
(6388)

BW  BWS-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$399.50 
G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
10076729
(1660)

MSA  10076729

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm



$568.60 
20100043
(6487)

DEGA  20100043

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Hydrogen cyanide (HCN) with range 0-50ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$645.12 
20100137
(6675)

DEGA  20100137

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Hydrogen cyanide (HCN) with range 0-50ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$897.60 
30100126
(6549)

DEGA  30100126

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-100ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$967.68 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GM/EC-01-16-12
(127)

GDS  GM/EC-01-16-12

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
ITRANS2-1940000
(6289)

OLDHAM  ITRANS2-1940000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,432.09 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, 0-30ppm

Configure

$1,438.30 
GMII-01-016-12/00-000-00/0-0
(140)

GDS  GMII-01-016-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,766.40 
GM/ECx-03-16-12-1-0900
(1814)

GDS  GM/ECx-03-16-12-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-16-12/00-00-00/0
(3290)

GDS  GMCX-01-16-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-03-016-12/00-000-00/1-0900
(1837)

GDS  GMIIx-03-016-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-16-12/00-00-00/1-0900
(3426)

GDS  GM/TX/01-16-12/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00 
Page: 1 | 2 | All