Gas leak detectors, analyzers, alarm devices and calibration gas
DEGA 0401079 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

DEGA NB III Gas Detection Transmitter with Catalytic Sensor for Explosive and Flammable gases with range 0-100% LEL. 4-20mA 3-Wire and RS-485 outputs. IP54.

$303.03      

  Availability 4 Weeks  ]

DEGA NB III transmitter is a part of the gas detection system. Transmitter is located in monitored premises in which critical situations due to accumulation of flammable or toxic substances can occur. Transmitter converts the measured concentration of substances into a unified signal 4 - 20mA and RS485.

The transmitter can be connected to control panels DEGA UPA III, DEGA UKA III and DEGA UDA III.


Dega general purpose gas detector transmitter

TECHNICAL SPECIFICATION:
Power supply8-28 V DC
Output:4 - 20 mA RS485
Cover protection levelIP 54
Input:1,2 W
Dimensions(WxHxD):100 x 110 x 40 mm
Weight0,3 kg
Sensor technology:catalytic, electrochemical, infrared, photoionization, semiconductor
Estimated life of sensor in clean environment:catalytic (1-2 years), electrochemical (1-3 years),infrared (minimum 5 years), photoionization (1 year), semiconductor (1-2 years)
Relative humidity of the ambient air:max. 95%
List of detected substances:BE1 - environment without danger of explosion
Export Info
Made inCzechia
Harmonized Tariff Code (HTC)9027102000

  • CALIBRATION GAS > HYDROGEN
    CYL-90301910 Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS > METHANE
    CYL-90090227 Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS > PROPANE
    CYL-10624200 Calibration Gas Propane (C3H8) 50% LEL 1.06%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • MULTI-POINT CONTROLLERS > 16 OR 32 CHANNEL
    0302092 DEGA UPA III Gas Detection Controller/Alarm Panel for 8 4-20mA analog gas detectors and up to 32 Dega gas detectors over RS-485. Dega/Modbus RS-485 Modbus Host port. 10 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for ..

  • MULTI-POINT CONTROLLERS > 4 OR 8-CHANNEL
    0301036 DEGA UKA III Gas Detection Controller/Alarm Panel for up to 8 Dega gas detectors over RS-485. 5 alarm relays. Includes 2 relay outputs for visual and sound alarm, 1 relay output for emergency solenoid valve and 1 4-20mA control output. IP54. ..

  • SOFTWARE > DEGA
    0901010 DegaConfig Software for configuration and remote detector support, custom settings and real-time monitoring of DEGA Alarm Panels and Gas Detectors, detector configuration and alarm relays via RS-485, controller detector configuration, relay cause and eff ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> LEL CATALYTIC BEAD :    28 Items found.
0401056
(6451)

DEGA  0401056

DEGA NB III Gas Detection Transmitter with Catalytic Sensor for Methane (CH4), Butane (C4H10), Petrol Vapours Hexane (C6H14), Acetylene (C2H2) or Hydrogen (H2) with range 0-100% LEL. 4-20mA 3-Wire and RS-485 outputs. IP54.

Configure

$283.48 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$329.88 
0402058
(6452)

DEGA  0402058

DEGA NS II Gas Detection Transmitter with Catalytic Sensor for Methane (CH4), Propane (C3H8), Butane (C4H10), Petrol Vapours Hexane (C6H14), Acetylene (C2H2), Hydrogen (H2) or Other Gases with range 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$386.11 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$396.45 
0402066
(6504)

DEGA  0402066

DEGA NS II Gas Detection Transmitter with Catalytic Sensor for Explosive and Flammable Gases with range 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$400.78 
0407150
(6453)

DEGA  0407150

DEGA NS II LCD RE Gas Detector with Catalytic Sensor for Methane (CH4), Propane (C3H8), Butane (C4H10), Petrol Vapours Hexane (C6H14), Hydrogen (H2) or Other Gases with range 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$439.88 
0407157
(6532)

DEGA  0407157

DEGA NS II LCD RE Gas Detector with Catalytic Sensor for Explosive and Flammable Gas with range 0-100% LEL. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$459.43 
SPC3-3380-200US
(2910)

INTEC  SPC3-3380-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Ammonia, Ethylene, Ethyl Alcohol, Ethyl Acetate, Benzene, n-Hexane, n-Heptane, Hydrogen, Isopropyl Alcohol and Methanol.

Configure

$529.88 
SPC3-3355-200US
(2911)

INTEC  SPC3-3355-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Methane, Methyl Ethyl Ketone, n-Butane, n-Octane, n-Pentane, Propane, Acetone, Jet A, JP8 and Toluene.

Configure

$529.88 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$595.17 
GDS-48-1-71-06
(343)

GDS  GDS-48-1-71-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Catalytic Bead for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. CSA Certified for Div. 1 Explosion Proof.

Configure

$760.00 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$783.00 
EX-_GENL-100L-O
(6021)

MACURCO  EX-GENL-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Combustible Gases 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1. Optional calibration to Methane, Propane, Pentane, Methanol, Hydrogen, Ethylene, Acetone, Butanol, Butane, Benzene and other combustibles.

Configure

$958.38 
SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (natural gas) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,075.71 
ITRANS2-1B20000
(6291)

OLDHAM  ITRANS2-1B20000

Oldham iTrans 2 Fixed Gas Detector with catalytic smart sensor for Combustibles 0-100% LEL . 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals. Factory configured for Methane or Pentane.

965-525420-100
(5006)

DETCON  965-525420-100

Detcon MicroSafe FP-524D Smart gas detection Sensor designed to detect and monitor combustible gases with range 0-100% LEL using matched-pair catalytic bead sensor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. CSA and ISA Approved for Class I, Division 1, Groups B, C, & D.

5100-02-IT-A1-01-0-0
(3070)

SIERRA MONITOR  5100-02-IT-A1-01-0-0

Sierra Monitor 5200-02-IT Combustible 0-100% LEL Gas Leak Detector (Catalytic Bead) for methane and others gases. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

DG-TX7-17DG-XXC-X0
(6056)

SIMTRONICS  DG-TX7-17DG-XXC-X0

Simtronics MultiXplo DG-TX7 Intelligent Flammable Catalytic Bead Gas Detector for Combustibles: Methane (CH4), Propane (C3H8) or Butane (C4H10) 0-100% LEL. Stainless Steel housing with integral display. Configurable output. IP66. ATEX and IECEx approvals.

XCDRFDL
(3004)

HONEYWELL  XCDRFDL

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Configure

$1,355.29 
XNXUTAVNNCB1
(852)

HONEYWELL  XNXUTAVNNCB1

Honeywell XNX Universal Gas Detector Transmitter including MPD CATALYTIC BEAD sensor combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, INMETRO

Configure

$1,368.19 
Page: 1 | 2 | All