Detcon 961-940026-100g | Nitric Oxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DETCON   961-940026-100G

DETCON 961-940026-100G
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Detcon DM-100-NO Electrochemical Nitric Oxide (NO) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-940026-100G   
Please Email us your request for quote   

Terminal Material
Approval
Alarm Relay Module

   3 Weeks  ]
9 Variants of base SKU

Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a 3⁄4 inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features
  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
Applications
  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Span Drift<5% signal loss per year (in first 2 years)
OutputsLinear 4-20 mA DC
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Measurement Range0-100 ppm, Other ranges available
Safety ApprovalsCCSAUS
Sensor Life/WarrantyPlug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5" (140mm) center to center
Weight2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)
Electrical Specifications
Power Input11 - 30 VDC
Power ConsumptionNormal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)< br/> 0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Status IndicatorsOptional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
943-000000-000
(6566)

DETCON  943-000000-000

Detcon Calibration Sleeve/Wind Guard for use with sensor splash guard for all Detcon sensor heads.



 
> NITRIC OXIDE :    16 Items found.
M001-0015-000
(6003)

MPOWER  M001-0015-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitric Oxide (NO) 0-250ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
BWS1-N-Y
(6390)

BW  BWS1-N-Y

BW Solo Serviceable Single-gas Detector for Nitric oxide (NO) 0-250 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6724
(6808)

PROSENSE  PC3-6724

Prosense PC3-6724 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$746.46 
P-6734
(6783)

PROSENSE  P-6734

Prosense P-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$823.68 
PQN-6734-1/2
(6956)

PROSENSE  PQN-6734-1/2

Prosense PQN-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,003.86 
2106B1418
(1464)

HONEYWELL  2106B1418

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitric Oxide (NO) 0-100 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6734-1/2
(6744)

PROSENSE  PQD-6734-1/2

Prosense PQD-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
41001AL-0-1023/0025P/L0
(7173)

RC SYSTEMS  41001AL-0-1023/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1023/0025P/L0
(7174)

RC SYSTEMS  51001AL-0-1023/0025P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
2100AL-0-9023/007P/L0
(7140)

RC SYSTEMS  2100AL-0-9023/007P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,789.61 
S3KUL2-XNXXSM1SS
(697)

HONEYWELL  S3KUL2-XNXXSM1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring NITRIC OXIDE (NO) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-100ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,789.84 
SPXCDULND2
(1900)

HONEYWELL  SPXCDULND2

Honeywell Sensepoint XCD RTD Gas Detector for Nitric Oxide (NO) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 100 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9023/025P/L0
(5785)

RC SYSTEMS  31001AL-0-9023/025P/L0

RC Systems SenSmart 3100 3 wire gas detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$2,145.28 
967-949490-100
(6095)

DETCON  967-949490-100

Detcon DM-700-NO Electrochemical Smart Nitric Oxide (NO) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSM1SS
(848)

HONEYWELL  XNXUTAENNNNN-XNXXSM1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitric oxide (NO) 0-100ppm compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,275.97 
6100AL1-0-1023/0025P
(7011)

RC SYSTEMS  6100AL1-0-1023/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Nitric Oxide (NO) 0-25ppm to 0-100ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class 1 Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.