Gds Gds-68s2xp-3/37-40-05/1-1-0 | Mercaptan | Odorant In Natural Gas | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-68S2XP-3/37-40-05/1-1-0

GDS GDS-68S2XP-3/37-40-05/1-1-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-68S2XP Natural Gas Odorant Monitoring system for positive pressure with regulator and standard coalescing filter, stainless steel sensor head with flow cell configured for Mercaptan (TMB) in natural gas with range 0-50 mg/m3, optional THT, Sulfur based odorants . Includes flow meter, diaphragm pump, 4-20mA and RS-485 MODBUS outputs. Integrated Bluetooth wireless interface communicates with GDS Connect App on iOS devices. Designed for installation in Class I Div 1 Hazardous Areas.

GDS-68S2XP-3/37-40-05/1-1-0   
Please Email us your request for quote   

Gas
Output Options
Enclosure Options
All enclosures include stainless steel bulkhead fittings as required.
Enclosure Heater
Insulation Kit
Sensor Conditioning Box
Ships with Sensor in Sensor Conditioning Unit. Sensor must be installed before use!
Cal Cilinder Mount Kit
Satellite Remote
Assembled and integrated Class I Division 2 satellite communications package connected via Modbus to the GDS-68, web GUI through Bluetick. Monthly service nor one-time initial activation fees not included.

   12 Weeks  ]
120 Variants of base SKU / 30 Shown

The GDS-68SXP Odorant Monitor uses industry-proven electrochemical sensor technology to measure the level of odorants in natural gas. Sensors are available for mercaptans, tetrahydrothiophene (THT) and blends such as Spotleak ® by Arkema and Scentinel ® from Chevron Phillips.

Scentinel ® from Chevron Phillips. The GDS-68SXP Monitor offers an alternative to expensive analyzers or constant monitoring using pull tubes. While federal regulations still require human ‘sniffers’, the GDS-68SXP provides a cost-effective, automated and objective way to continuously measure and report odorant levels throughout a natural gas distribution network.

Reliable Measurements Day & Night

The GDS-68 SXP Odorant Monitor automates the entire measurement process. Before displaying the calculated value, each result is verified for proper gas flow, zero drift, overrange, sensor response and more.

Designed for Remote Environments

The GDS-68SXP is designed to be installed in remote, unattended locations. Power usage is less than 10 watts, making solar-powered operation practical and reliable. Automatic calibration allows the GDS-68SXP to periodically perform System Calibration cycles on daily, weekly or monthly intervals. Error conditions are reported as multi-level fault values, allowing remote diagnosis via the 4-20mA analog output or RS-485 MODBUS interface.

Advanced User Interface with Bluetooth ® Wireless Technology

The GDS-68SXP features a large, easy-to-read color screen that displays the current reading, system status, time to next measurement and more. The companion GDS Connect iOS app for iPhone ® connects to the GDS-68SXP via an internal Bluetooth wireless interface and allows the user to monitor or change settings and issue commands if GDS-68SXP user security settings allow.

Hazardous Areas

The GDS-68SXP is designed for use in Class I Division 1 hazardous areas and includes all rated components.

FEATURES

  • Designed for use in Class I, Div 1 Hazardous Locations
  • Sensors for mercaptan, THT and common odorant mixtures
  • Large LCD color display shows current reading, alarms & status
  • GDS Connect App provides local wireless monitoring and control
  • Manual or automatic calibration from stream or cal reference gas
  • Gas and air flow sensor detects closed valves & blocked lines
  • Automatic overrange detection protects sensor from damage
  • Built-in flow meter provides visual confirmation of gas flow rate
  • Outputs include 4-20mA output and RS-485 Serial MODBUS
  • Units available: lbs per million feet, ppm or mg /cubic meter
  • Latest generation GASMAX CX sensor with Digital Smart Sensors
  • High quality diaphragm pump with 24VDC brushless motor
  • Security levels reduce risk of tampering by unauthorized personnel
  • Manufactured in USA
APPLICATIONS

  • Gas Pipeline Monitoring
  • Odorant Monitoring
  • Custody Transfer Compliance

GDS-68SXP SPECIFICATIONS
Power Input: 24VDC +/- 5% at < 10 watts.
Optional heater requires 110 / 220VAC at 200 watts max
Primary Display Backlit high resolution color LCD display shows latest reading, calibration and sample history and more
Sample Rate From 48 samples per day to 1 sample per day
Repeatability 5% of range
Analog Output Standard 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply.
Digital Output RS-485 serial 2-wire MODBUS slave interface.
User programmable security levels allow for read / write or read-only modes
Wireless Output Integrated Bluetooth wireless interface.
User programmable security levels allow for full enable / disable and wireless read / write or read-only modes
System Calibration User-initiated (“Manual”) system calibration from calibration gas port or gas sample stream
Programmable automatic repeating system calibration from calibration gas on user-selected intervals from one day to six months.
Gas Sensor GASMAX CX with highly sensitive electrochemical sensors for Mercaptans, THT or gas odorant mixtures.
Includes sensor monitoring and temperature compensation for accurate measurements indoors or outdoors
Gas Sensor Calibration Prompted manual calibration for GASMAX CX gas sensor.
“Calibration Required” notice automatically generated.
Purge Air Pump Long life diaphragm pump with brushless 24VDC motor.
Sample Conditioning Max inlet pressure 1500 psig. High pressure stainless steel inlet filter with stainless steel regulator. Filter element PVDF fluorcarbon for removal of liquid aerosols, 99.99% removal of 0.1 micron particles.
Sample Temp +5°C (+41°F) to +50°C (+122°F)
Operating Temp 0°C (-13°F) to +50°C (+122°F)
Construction XP enclosure: Cast aluminum. GASMAX CX: Aluminum housing with epoxy paint standard; Exterior stainless steel tubing and fittings. Backplate epoxy painted steel
Dimensions (Plate only) 21” x 21” x 8”
11.3 Kg / 25 pounds
Dimensions (NEMA 4X) 24” x 24” x 8” Non-metallic (20 Kg / 45 pounds)
24” x 24” x 8” Stainless Steel Enclosure
Inlet / Outlet 1/4” compression, stainless steel
Approvals GASMAX CX, enclosures and flame arrestors CSA
Certified for Class I, Div 1, Grps B, C, D.
Suitable for XP installations
System Security Low setting - all user interaction allowed
Medium setting - operation from menu, no remote control
High setting - No access to menu without security code
Warranty Electronics - 2 years from date of purchase

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
20-0141
(3542)

GDS  20-0141

GDS Duct Sample Kit for GDS-58XP, GDS-58NXP and GDS-68XP sample draw gas detectors



 
1200-0825
(3215)

GDS  1200-0825

GDS Gas Detector Calibration Gas Cylinder Tert-Butyl Mercaptan (C4H10S/TBM) 5ppm. Balance Methane. 100L Aluminium Cylinder.

1200-0796
(3145)

GDS  1200-0796

GDS Gas Detector Calibration Gas Kit Tert-Butyl Mercaptan (C4H10S) 5ppm. Balance Nitrogen. Kit includes a 100L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9830-R11
(3370)

GDS  10-9830-R11

Electrochemical Smart Sensor configured for Mercaptan (TBM) with range 0-14 ppm / 0-50 mg/m3. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.

SP-5
(4372)

GDS  SP-5

GDS SP-5 solar power system, 5 watts (430mA) of DC power for up to 5 days of low sun conditions, or 3 watts for up to 7 days of low sun conditions. Includes 80Wsolar panel, battery enclosure with pre wired electronic charge controller, 99AH gelled electrolyte battery, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

SP-12
(4374)

GDS  SP-12

GDS SP-12 solar power system, 12 watts (1.0A) of DC power for up to 5 days of low sun conditions, or 5 watts for up to 10 days of low sun conditions. Includes 150W solar panel, battery enclosure with pre wired electronic charge controller, two 84AH gelled electrolyte batteries, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

GDS-68S2XP-3/37-41-05/1-1-0
(6231)

GDS  GDS-68S2XP-3/37-41-05/1-1-0

GDS GDS-68S2XP Natural Gas Odorant Monitoring system for positive pressure with regulator and standard coalescing filter, stainless steel sensor head with flow cell configured for Tetrahydrothiophene (THT) in natural gas with range 0-50 mg/m3. Includes flow meter, diaphragm pump, 4-20mA and RS-485 MODBUS outputs. Integrated Bluetooth wireless interface communicates with GDS Connect App on iOS devices. Designed for installation in Class I Div 1 Hazardous Areas.

Cookie Notice