Detcon Model 100 H2S Hydrogen Sulfide (H2S) 0-10ppm to 0-2% Analyzer with 3-Electrode Electrochemical sensor. Continuos, accurate and real-time measurement. Includes 4-20mA, alarm relay and RS-485 outputs.

Part# with Options:        952-053200-200
Price with Options:        Please Email us your request for quote   

Options:    

Range
(1) Range for Detcon Model 1000 H2S
Enclosure
(2) Enclosure for Detcon Model 1000 H2S
Air Flow Fault
(3) Air Flow Fault for Detcon Model 1000 H2S

  Availability 3 Weeks  ]


Detcon Model 1000-H2S Analyzer is designed to provide continuous, accurate, real-time measurement of hydrogen sulfide gas concentrations in a wide variety of process gas streams. With new technology and design, the Process Analyzer has a measurement range of 0-1,000 ppm with up to 2% standard and up to 5% with additional high range applications packaging. All H2S analyzers in the Model 1000 Series employ Detcon’s 3-Electrode Electrochemical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The instrument package is rated for Non-Hazardous areas.

Features
  • Continuous Measurement with Superior Uptime
  • Ranges from 0-1,000 ppm up to 5% by Volume
  • Readily Field Replaceable Sensors
  • Simple Operation and Field Calibraton
  • Standard Outputs: 4-20 mA, RS-485, 3 Relays
  • Non-Hazardous Areas rated
Applications
  • Gas Well Testing & Analysis
  • Gas Well Production Sites
  • Gas Treatment Plants
  • Gas Transmission Custody Transfer Compliance

Specifications
Sensor Type3-Electrode Electrochemical
Measurement RangeLow Range
0-1,000 ppm
0-2%
High Range
0-5%
Other ranges available on request
Accuracy/Repeatability±10% of reading or ±2.5% of range whichever is greater
Response/Clearing TimeT50 <30 seconds
T90 <1 minute
Max output to over-range gas: <10 seconds
Operating Temperature Range-40°F to +122°F; -40°C to +50°C
Operating Pressure RequirementsInlet: 10 ±2 psig
Vent: Atmospheric ±1 psig
OutputsLinear 4-20 mA DC
RS-485 ModbusTM
3 Relays (alarm 1, alarm 2, & fault)
Contacts rated 5 amps
Power Input117/220 VAC
18-36 VDC
Electrical ClassificationNon-Hazardous Areas
WarrantySensor: 6 months
Transmitter: 2 year
Analyzer Weight80 lbs.
Shipping Weight140 lbs
Dimensions29” x 29” x 8”