Gas leak detectors, analyzers, alarm devices and calibration gas
DETCON 965-333380-010 (1)
  • Overview
  • Benefits
  • Specs
  • Literature

Detcon DM-500-HF Electrochemical Hydrogen Flouride (HF) 0-10ppm Sensor Assembly with IS stainless steel and ABS plastic housing. Includes Backlit LCD and LED Indicators. 4-20mA output. Explosion proof. NEMA 4X. IP66. CSA and UL approvals for Class I, Div 1, Groups B, C & D.

Part# with Options:        965-333380-010
Price with Options:        Please Email us your request for quote   

Options:    

Junction Box
(1) Junction Box for Detcon DM-500

  Availability 2 Weeks  ]

Detcon Model DM-500IS-HF sensor is designed to detect and monitor HF in air over the range 0-10 ppm. The sensor assembly consists of an electrochemical fuel cell mounted in an Intrinsically Safe stainless steel and ABS plastic housing that includes a splashguard with integral cal port, a signal conditioning control transmitter circuit, a base connector board and an explosion proof junction box. The Intrinsically Safe sensor housing design allows direct contact of the target gas to the electrochemical sensor, thus maximizing response time, detectability and repeatability. And because the Intrinsically Safe housing design does not use a stainless steel flame arrestor, it eliminates inaccurate readings due to target gas absorption.

Features
  • CSA and UL Approved: Class 1, Div. 1, Groups B, C, & D
  • 4-20 mA output
  • Simple menu driven calibration - takes less than 3 minutes
  • Backlit LCD, and LED indicators for Fault, and Cal status
  • Universal plug-in transmitter
  • Intrinsically Safe Sensor Housing
  • Plug-in field-replaceable transmitter
  • Electrochemical plug-in sensor

Specifications
Sensor TypeElectrochemical Fuel Cell
Measurement Range0-10 ppm Hydrogen Fluoride
Other ranges available
Repeatability±2% FS
Response/Clearing TimeT90 <30 seconds
Span Drift<2% signal loss per month
Operating Temperature Range-40°C to +50°C; -40°F to +122°F
Operating Humidity Range15-90% RH non-condensing
OutputLinear 4-20 mA DC
Input Voltage11.5-28 VDC
Power Consumption1.6 watts @ 24 VDC
Electrical ClassificationExplosion proof
Class 1, Div. 1, Groups B, C, D
Ingress ProtectionNEMA 4X, IP66
Sensor Life/WarrantySensor: 2 year warranty
Transmitter: 2 year warranty
Safety ApprovalsCSA/NRTL (US OSHA Certified)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > HYDROGEN FLUORIDE :    12 Items found.
M001-0014-000
(6000)

MPOWER  M001-0014-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Fluoride (HF) 0-10ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
961-330026-010G
(6367)

DETCON  961-330026-010G

Detcon DM-100-HF Electrochemical Hydrogen Fluoride (HF) 0-10ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSF1SS
(693)

HONEYWELL  S3KUL2-XNXXSF1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN FLUORIDE (HF) with electrochemical sensor, 2-wire 4-20mA loop, 0-12.0ppm

Configure

$1,396.01 
GM/EC-03-18-02
(130)

GDS  GM/EC-03-18-02

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-5 to 0-10 ppm, 4-20 mA output transmitter.

Configure

$1,575.00 
967-333390-010
(6092)

DETCON  967-333390-010

Detcon DM-700-HF Electrochemical "Smart" Hydrogen Fluoride (HF) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSF1SS
(844)

HONEYWELL  XNXUTAENNNNN-XNXXSF1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Fluoride (HF) 0-12.0ppm compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,730.85 
GMII-03-018-02/00-000-00/0-0
(142)

GDS  GMII-03-018-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-5 to 0-10 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,745.00 
GM/ECx-03-18-02-1-0900
(1816)

GDS  GM/ECx-03-18-02-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Fluoride (HF) with range 0-5, 0-10 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$2,125.00 
GMCX-03-18-02/00-00-00/0
(3292)

GDS  GMCX-03-18-02/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Hydrigen Fluoride (HF) with range 0-5 to 0-10 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. For non-clasified areas only

Configure

$2,240.00 
5100-26-IT-A1-01-0-0
(3080)

SIERRA MONITOR  5100-26-IT-A1-01-0-0

Sierra Monitor 5200-26-IT Toxic Gas Leak Detector for Hydrogen Fluoride (HF) 0-10ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

GMIIx-03-018-02/00-000-00/1-0900
(1839)

GDS  GMIIx-03-018-02/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-5, 0-10 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,335.13 
GM/TX/03-18-02/00-00-00/1-0900
(3428)

GDS  GM/TX/03-18-02/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head (non-XP) and integrated sensor configured for Hydrigen Fluoride (HF) with range 0-5 to 0-10 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,365.00