Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (6075)

DETCON  967-747490-010

DETECTORS / GAS DETECTORS
CHLORINE




DETCON 967-747490-010 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Documents

Detcon DM-700-CL2 Electrochemical "Smart" Chlorine (CL2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Part# with Options:        967-747490-010
Price with Options:        Please Email us your request for quote   

Options:    

Junction Box
(1) Junction Box for Detcon DM-700
Options
(2) Options for Detcon DM-700
Integration Modules
(3) Integration Modules for Detcon Series 700
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
(4) Mounting Options for Detcon Series 700
Additional Modules
(5) Additional Modules for Detcon Series 700

  Availability 2 Weeks  ]

Detcon Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Oil & Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Wastewater Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
3-electrode electrochemical cell
Plug-in field replaceable Type
Measurement Range0-10 ppm
Accuracy/Repeatability±2% FS
Response/Clearing TimeT90≤60 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIB + H2 T4 GB
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsCCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range15-90% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mechanical Connection:
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionNormal operation = 30mA @24V (<0.75 watt)
Maximum = 50mA @24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate (optional)9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity

  • SENSORS (REPLACEMENT) > DETCON
    377-747401-010 Detcon Chlorine (CL2) plug-in sensor for DM-700-CL2..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > CHLORINE :    29 Items found.
A-ALT-PRO-10076716
(1658)

MSA  A-ALT-PRO-10076716

MSA ALTAIR Pro Portable Single-gas Detector for Chlorine (Cl2) 0-20 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 0.5 ppm, High 1 ppm, STEL 1 ppm, TWA 0.5 ppm *** Discontinued, replaced by 10154080 ***



 
045-0516-000
(3031)

RAE  045-0516-000

ToxiRAE II PGM-1190 Personal Portable Sigle-Gas Monitor For Chlorine 0-10ppm (Cl2). Provides continuos display of the gas concentration, STEL, TWA and peak values. Field repleaceable sensor, filter and battery. IP-65. UL, ATEX, CeMark and IECEx Approved. *** Discontinued replaced by ToxiRAE 3 ***



 
MP100-Cl2-10
(5995)

MACURCO  MP100-Cl2-10

Macurco UNI Portable Single Gas Detector for detection of Chlorine (Cl2) 0-10ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$276.25 
GAXT-C-DL
(481)

BW  GAXT-C-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Chlorine (Cl2) 0-50 ppm.

Configure

$417.12 
G02-B610-100
(3021)

RAE  G02-B610-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Chlorine (Cl2) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
SPSTAXL1
(1482)

HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

Configure

$594.91 
10154080
(4401)

MSA  10154080

MSA ALTAIR 2X Portable Single Gas Detector with XCell Sensor Technology for Chlorine (Cl2) 0.5-1ppm. Offers superior stability, accuracy, and sensor life. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. Minimal rF interference. IP67. cCSAus, ATEX and IEC Approved.



$617.60 
8318978
(2641)

DRAEGER  8318978

Draeger Pac 7000 small single gas detector for Chlorine (Cl2) 0-20 ppm for personal monitoring. TWA and STEL alarms. IP65. CE, ATEX, UL, IECEx, MED and ATEX Approvals. Class I, II Div 1.



$624.68 
GG-Cl2-B-5
(2962)

CALIBRATION TECHNOLOGIES  GG-Cl2-B-5

CTI GasGuard Cl2 Chlorine Electrochemical Sensor (0-5 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$639.45 
364-455-01-365-782-11
(6151)

DELPHIAN  364-455-01-365-782-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Chlorine (Cl2) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$758.40 
GG-CL2-5-EXP
(5977)

CALIBRATION TECHNOLOGIES  GG-CL2-5-EXP

CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$813.45 
2106B1410
(1456)

HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$841.60 
GDS-49-3-12-02
(160)

GDS  GDS-49-3-12-02

GDS GDS-49 Remote Gas Detector Transmitter with stainless steel sensor head (non-XP) configured for Chlorine (CL2) with range 0-5 to 0-50 ppm. 2-Wire 4-20 mA transmitter.

Configure

$885.00 
EX-CL2-5P-O
(6017)

MACURCO  EX-CL2-5P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Chlorine (CL2) 0-5ppm. Includes 4-20 mA Output, Three Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,112.53 
TM-EC-48-12-02-0
(3387)

GDS  TM-EC-48-12-02-0

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head and integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

Configure

$1,150.00 
SPXCDULNL2
(1898)

HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2.

Configure

$1,217.31 
TMII-48-12-02/00-00-00/0-0
(149)

GDS  TMII-48-12-02/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head (non-XP) with integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$1,275.00 
S3KUL2-XNXXSL1SS
(687)

HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE (CI2) with electrochemical sensor, 2-wire 4-20mA loop, 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

Configure

$1,313.67 
GM/EC-03-12-02
(118)

GDS  GM/EC-03-12-02

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter.

Configure

$1,435.00 
GMII-03-012-02/00-000-00/0-0
(136)

GDS  GMII-03-012-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,605.00 
Page: 1 | 2 | All