Gas leak detectors, analyzers, alarm devices and calibration gas
DETCON 967-747490-010 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Literature

Detcon DM-700-CL2 Electrochemical "Smart" Chlorine (CL2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Part# with Options:        967-747490-010
Price with Options:        Please Email us your request for quote   

Options:    

Junction Box
(1) Junction Box for Detcon DM-700
Options
(2) Options for Detcon DM-700
Integration Modules
(3) Integration Modules for Detcon Series 700
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
(4) Mounting Options for Detcon Series 700
Additional Modules
(5) Additional Modules for Detcon Series 700

  Availability 2 Weeks  ]

Detcon Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Oil & Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Wastewater Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
3-electrode electrochemical cell
Plug-in field replaceable Type
Measurement Range0-10 ppm
Accuracy/Repeatability±2% FS
Response/Clearing TimeT90≤60 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIB + H2 T4 GB
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsCCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range15-90% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mechanical Connection:
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionNormal operation = 30mA @24V (<0.75 watt)
Maximum = 50mA @24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate (optional)9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > DETCON
    377-747401-010 Detcon Chlorine (CL2) plug-in sensor for DM-700-CL2 ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE :    28 Items found.
M001-0004-000
(5995)

MPOWER  M001-0004-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine (Cl2) 0-50ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$298.00 
BWS_-C-Y
(6384)

BW  BWS-C-Y

Honeywell BW Solo Serviceable Single-gas Detector for Chlorine (Cl2) 0-50 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$413.60 
GAXT-C-DL
(481)

BW  GAXT-C-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Chlorine (Cl2) 0-50 ppm.

Configure

$551.76 
G02-B610-100
(3021)

RAE  G02-B610-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Chlorine (Cl2) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
SPSTAXL1
(1482)

HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

Configure

$582.25 
10154080
(4401)

MSA  10154080

MSA ALTAIR 2X Portable Single Gas Detector with XCell Sensor Technology for Chlorine (Cl2) Range 0-10 ppm. Low Alarm 0.5ppm, High Alarm 1ppm. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. IP67. cCSAus, ATEX and IEC Approved.



$651.22 
GG-CL2-B-5
(2962)

CALIBRATION TECHNOLOGIES  GG-CL2-B-5

CTI GasGuard Cl2 Chlorine Electrochemical Sensor (0-5 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$661.20 
364-455-01-365-782-11
(6151)

DELPHIAN  364-455-01-365-782-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Chlorine (Cl2) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$758.40 
2106B1410
(1456)

HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$823.69 
GG-CL2-5-EXP
(5977)

CALIBRATION TECHNOLOGIES  GG-CL2-5-EXP

CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$843.90 
GDS-49-3-12-02
(160)

GDS  GDS-49-3-12-02

GDS GDS-49 Remote Gas Detector Transmitter with stainless steel sensor head (non-XP) configured for Chlorine (CL2) with range 0-5 to 0-50 ppm. 2-Wire 4-20 mA transmitter.

Configure

$885.00 
EX-CL2-5P-O
(6017)

MACURCO  EX-CL2-5P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Chlorine (CL2) 0-5ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,140.34 
SPXCDULNL2
(1898)

HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2.

Configure

$1,167.11 
S3KUL2-XNXXSL1SS
(687)

HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE (CI2) with electrochemical sensor, 2-wire 4-20mA loop, 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

Configure

$1,285.72 
ITRANS2-1720000
(6287)

OLDHAM  ITRANS2-1720000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Chlorine (Cl2) 0.2-99.9 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

100-0008-A1/100-0015-Cl2
(4750)

ESP SAFETY  100-0008-A1/100-0015-Cl2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL certification.

Configure

$1,401.60 
GM/EC-03-12-02
(118)

GDS  GM/EC-03-12-02

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter.

Configure

$1,435.00 
961-740026-010G
(6353)

DETCON  961-740026-010G

Detcon DM-100-CL2 Electrochemical Chlorine (Cl2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GMII-03-012-02/00-000-00/0-0
(136)

GDS  GMII-03-012-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,605.00 
5100-06-IT-A1-01-0-0
(3074)

SIERRA MONITOR  5100-06-IT-A1-01-0-0

Sierra Monitor 5200-06-IT Toxic Gas Leak Detector for Chlorine (Cl) 0-10ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

Page: 1 | 2 | All