Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (6019)

MACURCO  EX-B2H6-2P-O

DETECTORS / GAS DETECTORS
DIBORANE

$1,574.12     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



MACURCO EX-B2H6-2P-O (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Diborane (B2H6) 0-2ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Part# with Options:        EX-B2H6-2P-O
Price with Options:        1,574.12

Options:    

Remote Sensor
(1) Remote Sensor Head Assembly for Macurco Ex Series
Up to 100 meters over RS-485

  Availability 4 Weeks  ]

The Macurco EX Series of Explosion Proof Gas Detectors are used for Class 1 Division 1 applications or harsh environments. A brilliant digital display indicates STEL, TWA and peak daily value concentrations as well as relay status. A three-color backlight will flash depending on the level of alarm for operator safety. Set-up and calibration is accomplished via non-intrusive magnetic interface that allows programming of all parameters. A remote sensor option is available for difficult or remote monitoring applications. Compatible sensor types include electrochemical and catalytic bead options to provide monitoring solutions for a wide variety of toxic and combustible gas applications. Standard outputs include Modbus RS-485, 4-20 mA and three user programmable relay contacts.

FEATURES & BENEFITS
  • RS-485 Communication
  • Three Onboard Relays
  • 4-20 mA Output
  • Non-Intrusive Magnetic Calibration
  • Status Indicating Warning Screens
  • Display of TWA, STEL, Peak Daily Value
  • Electrochemical & Catalytic Bead Sensor Technologies
  • Built-in Clock
APPLICATIONS
  • Chemical / Petrochemical
  • Environmental Monitoring
  • Food & Beverage
  • Pharmaceutical
  • General Industry
  • Power Generation
  • Oil & Gas Upstream
  • Pulp & Paper
  • Oil & Gas Midstream
  • Water & Wastewater
  • Oil & Gas Downstream
  • Cold Storage / Warehousing
  • Extraction Facilities
  • Alcohol Distilleries

GENERAL SPECIFICATIONS
Size 5.7 x 7.5 x 5.1 in. (14.5 x 19.1 x 13 cm)
Weight 4.2 lb. (1.95 kg)
Operating Temp -40° to 158° F (-40° to 70°C)
Ambient Humidity 5-95% RH Non-Condensing
Sensor Type Combustible Gases: Catalytic
Toxic Gases & Oxygen: Electrochemical
ELECTRICAL SPECIFICATIONS
Input Power 24 VDC nominal, range 18 to 30 VDC, 0.3 A DC Total Max.
24 VAC nominal, range 12 to 24 VAC, 0.3 A AC Total Max.
(AC must not be grounded)
Fuse F2 on Main Board: Polyswitch 750 mA
Polyswitch device resets after fault is cleared and power to the circuit is removed
Relays Three Relays, SPDT, Dry Contacts
1.0 A maximum at 30 VDC (resistive load)
0.3 A maximum at 125 VAC (resistive load)
MECHANICAL SPECIFICATIONS
Display LCD graphic display with backlight
Keypad Three Non-Intrusive Magnetic switches - F1, F2, F3
Enclosure Aluminium Pressure Die-Casting
Entries: 2 x 3/4” NPT
Certificate FM 3615, CSA C22.2 No.30
Class I, Groups A, B, C, D, Class II, Groups E, F, G; Class III
Enclosure Type: 4X, Division 1 Division 2
ANSI/ISA 12.22.01
Class I, Zone 1 AExd II C, IP66 Zone 1
CSA E60079-1 Ex d II C, Class I, Zone 1, IP66
Status Indicators Five Status LED’s
RS-485 TX Status (Green)
RS-485 RX Status (Green)
Relay 1 Status (Red)
Relay 2 Status (Red)
Relay 2 Status (Red)

  • ADAPTERS > MACURCO
    EX-6395-0003 Macurco Calibration Adaptor (cup) for Macurco Ex Series Toxic Gases ..

  • CALIBRATION GAS > MACURCO
    70-2900-0228-5 Macurco Zero Air Calibration Gas 58L (F) for Macurco Ex Series ..

  • FLOW > MACURCO
    26-1017-5404-7 Macurco 0.5 LPM Fixed Flow Regulator (Male) for Macurco Ex Series detectors. ..

  • TUBING > MACURCO
    26-2900-0082-5 Macurco 3ft Teflon Tubing for Macurco Ex Series ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> DIBORANE :    8 Items found.
GM/EC-01-32-02
(1646)

GDS  GM/EC-01-32-02

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Diborane (B2H6) with range 0-5 ppm, 4-20 mA output transmitter.

Configure

$1,690.00 
967-192190-005
(6078)

DETCON  967-192190-005

Detcon DM-700-B2H6 Electrochemical "Smart" Diborane (B2H6) 0-5 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

GMII-01-032-05/00-000-00/0-0
(1653)

GDS  GMII-01-032-05/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Diborane (B2H6) with range 0-5 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,860.00 
961-210026-005G
(6355)

DETCON  961-210026-005G

Detcon DM-100-B2H6 Electrochemical Diborane (B2H6) 0-5ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GM/ECx-01-32-02-1-0900
(1830)

GDS  GM/ECx-01-32-02-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (XP, IS) configured for Diborane (B2H6) with range 0-5 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$2,240.00 
GMCX-01-32-05/00-00-00/0
(3306)

GDS  GMCX-01-32-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Diborane (B2H6) with range 0-5 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,355.00 
GMIIx-01-032-02/00-000-00/1-0900
(1853)

GDS  GMIIx-01-032-02/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head configured for Diborane (B2H6) with range 0-5 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,458.31 
GM/TX/01-32-05/00-00-00/1-0900
(3442)

GDS  GM/TX/01-32-05/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Diborane (B2H6) with range 0-5 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,480.00