Fireray 5000 Motorised Reflective Optical Beam (Open Path) Smoke Detector. Auto-aligning and self-correcting. Fire and trouble relays. Built in Laser assisted prism mounting. IP54. 26.25 ft. to 330 ft range. UL, ULC, MEA, CSFM, FM and Maryland listed.

Part# with Options:        5000-103
Price with Options:        570.00

Options:    

Additional Detector
(1) Additional Detector Head and 1 Prism for Liferay 5000
Additional Controller
(2) Additional Controller for Liferay 5000

  Availability 3 Days  ]

The Fireray ® 5000 System is an auto-aligning, self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition, each system controller houses two pairs of fire and trouble relays, one per detector. Once the detector head is installed, using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.

The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.

The system is designed to be mounted so the beam will project between 19” (0.5m) and 24” (0.6m) below the ceiling. Lateral detection may be up to 30ft. (9.144m) on either side of the beam, providing a maximum total coverage area of up to 19,800 square feet (60ft. x 330ft. or 18.29m x 100m). For installations complying with UL268/NFPA72, the maximum distance of Detector and Reflector from the ceiling must be 10% of the distance between floor and ceiling.

Engineering Specification

The projected beam type smoke detector shall be listed to U.L. 268 and shall consist of up to two integrated transmitter, receiver detector heads and single low level remote control unit. The detector shall operate between a range of 26.25 ft. to 330 ft. (8m to 100m). The temperature range of the system shall be -4°F to 131°F (-20°C to 55°C). The beam detector heads shall include an integral built-in laser pointer to assist prism mounting. The beam detector shall feature automatic gain control which will compensate for gradual signal deterioration from dirt accumulation on the lenses and prisms. The beams detector heads shall include AutoOptimise self-correcting motorized head feature to ensure unit is always receiving maximum signal available, and shall automatically compensate for building shift.

The unit shall include a low level remote display and control unit with LCD read-out for set-up, reporting and testing of up to 2 separate detector heads. The System shall have separate Trouble and Alarm relays for each of the 2 channels.

Features
  • Up to 2 Detector Heads reporting to One Ground Level Controller
  • Range of 26.25 ft. to 330 ft. (8m to 100m)
  • Built in Laser assisted prism mounting
  • Auto-Alignment 2 to 4 minutes per head
  • AutOptimise: Auto-Correction due to building shift
  • Built-in electronic UL/ULC/FM obscuration-acceptance fire test
  • Contamination compensation
  • Separate Trouble and Alarm relays for each of the 2 channels
  • Password protected settings
  • Low current draw 5 to 8.5mA
  • Built-in 1/2”/M-20 conduit knock-outs on the system controller
  • Programmable alarm thresholds: 10% - 60% in 1% increments
  • Programmable Fault and Alarm delay: 2-30 Seconds

The system shall be capable of programming alarm thresholds of 10% to 60% in 1% increments. The system shall be capable of programming delay to fault and delay to alarm from 2 seconds to 30 seconds in 1 second increments. Test and acceptance of the system shall be carried out by using the UL/ULC/FM approved internal electronic obscuration fire test. The projected beam type smoke detector shall be a 4-wire 24 VDC device to be used with a separately supplied 4-wire control panel. The Reflective beam type smoke detector shall be a FFE Ltd Fireray ® 5000.

Listings

UL - S3417
ULC - S3417
MEA - 22-08-E
CSFM - 7260-1508-105
FM Approved
Maryland - 2243

Fireray® 5000
Construction Specification
Housing Flame Retardant ABS
IP Rating: IP54
Finish: Grey/Black
Knock Outs: Controller: 7-1/2”/M-20
Detector Head: 1- 1/2”/M-20
Weight: Head & Controller 3.24 lbs (1.47 kg)
Dimensions: Head: 5.28” H x 5.16” L x 5.28” W
(134mm H x 131mm L x 134mm W)
Controller: 3.43” H x 9.06” L x 7.95” W
(87mm H x 230mm L x 202mm W)
Prism: 0.37” H x 4.13” L x 3.94” W
(9.5mm H x 105mm L x 100mm W)
Electrical Specification
Primary Input Power: 14 to 36 VDC
Standby Current: Low Current Mode: 5mA to 8.5mA @ 24VDC depending on number of detector heads used
High Current Mode: 37mA @ 24VDC
Alarm Current: 5mA to 8.5mA @ 24VDC depending on number of detector heads used
Relay Contacts: 1A @ 30 VDC Resistive
Reset Time: 5 Seconds maximum
Start Up Time: 45 Seconds
Optical Wavelength: 850nm.
Alarm Threshold: 10% - 60% (35% Default)
Temperature Rating: -4°F to 131°F (-20°C to +55°C) For UL Listed Installations, 32°F to 100°F (0°C to 38°C).
Relative Humidity: 10% to 93% RH non-condensing
Range: 26.25ft. to 330ft. (8m to 100m)
Cabling Between each Detector & Controller: 18-14 AWG 1-Pair

  • SMOKE OPEN PATH > INFRARED
    5000-003 Fireray Additional Controller for F-5000 System. Beige/black in color. ..

  • SMOKE OPEN PATH > INFRARED
    5000-031 Fireray Additional Detector Head and 1 Prism. To be used with 5000-103 System. Add up to 1 additional 5000-031 Heads to 1- 5000-103 System. Beige/black in color. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal

> INFRARED :    8 Items found.
6010-300
(6327)

FIRERAY  6010-300

Fireray One Reflective Motorized Projected Beam Type Smoke Detector. 24 VDC. 16.4 ft. to 393.6 ft range. Polycarbonate Housing. Includes 1 Prism, Individual Alarm and Fault relays. IP55.

Configure

$438.90 
5000-003
(4986)

FIRERAY  5000-003

Fireray Additional Controller for F-5000 System. Beige/black in color.



$438.90 
5000-031
(4985)

FIRERAY  5000-031

Fireray Additional Detector Head and 1 Prism. To be used with 5000-103 System. Add up to 1 additional 5000-031 Heads to 1- 5000-103 System. Beige/black in color.



$438.90 
50RU
(4983)

FIRERAY  50RU

Fireray 50RU/100RU Reflective Optical Beam (Open Path) Smoke Detector. Single unit with transmitter and receiver. IP50. 16.5 ft. to 160 ft and 160 ft. to 330 ft. ranges. Single compact housing. 12 VDC or 24 VDC operation. UL, MEA, ULC, CSFM, MEA and Maryland Listed.

Configure

$438.90 
3000-016
(4982)

FIRERAY  3000-016

Fireray Additional Transmitter and Receiver for Fireray 3000. System to a dual channel system. White in color.



$456.00 
3000-103
(4981)

FIRERAY  3000-103

Fireray 3000 End-to-End Infrared Optical Beam (Open Path) Smoke Detector for open area spaces with high ceilings. Includes a Low Level Controller and infrared transmitter and receiver. IP54. 16.5 to 393 feet range. Single and Twin Channel capability. Separate fire and fault relays. UL, ULC, CSFM and FM listed.

Configure

$581.40 
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$702.00 
PQD-3033
(6719)

PROSENSE  PQD-3033

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$936.00