The BExCTS110-05D is a flameproof telephone initiated combined alarm horn
sounder and Xenon strobe beacon which is certified to meet the requirements of the
ATEX directive 94/9/EC and the IECEx Scheme. The sounder / beacon produces a loud
audible signal and a visual signal, when triggered by a telephone ringing signal and
can be used in hazardous areas where potentially flammable atmospheres may be
present.
Thirty two different sounds can be selected by internal switches, (see tone table on Page 5). The
sounder produces output levels in the 110dB(A) range and the beacon produces an output level of 5
joules. The unit can be used in Zone 1 and Zone 2 areas with gases in groups IIA and IIB and with
Temperature Classifications of T1, T2, T3, and T4.
Features:
- The sounder and beacon can be set individually to either run
continuously or pulsed at the cadence of the ringing tone.
- Xenon tubes mechanically secured against shock & vibration
- Ratchet adjustable stainless steel ‘U’ bracket.
Approvals:
- ATEX certificate: KEMA 01ATEX2 2 2 3X,
EN 60079-0 : 2 006, EN 60079-1 : 2 007,
EN 612 41-0 : 2 006, EN 612 41-1 : 2 004
- IECEx certificate: IECEx KEM 10.002 5,
IEC 60079-0 : 2 004 (Ed4), IEC 60079-1 : 2 007 (Ed6),
IEC 612 41-0 : 2 004 (Ed1), IEC 612 41-1 : 2 004 (Ed1)
- GOST-R certificate: PO CC G B.JB05.B03365
Stage 1 |
WAV file |
Frequency Description. |
T 1 |
 |
Continuous 1000Hz Toxic Gas Alarm |
T 2 |
 |
Alternating 800/1000Hz at 0.25s intervals |
T 3 |
 |
Slow Whoop 500/1200Hz at 0.3Hz with 0.5s gap repeated |
T 4 |
 |
Sweeping 800/1000 at 1Hz |
T 5 |
 |
Continuous at 2400Hz |
T 6 |
 |
Sweeping 2400/2900Hz at 7Hz |
T 7 |
 |
Sweeping 2400/2900Hz at 1Hz |
T 8 |
 |
Siren 500/1200/500Hz at 0.3Hz |
T 9 |
 |
Sawtooth 1200/500Hz at 1Hz |
T 10 |
 |
Alternating 2400/2900Hz at 2Hz |
T 11 |
 |
Intermittent 1000Hz at 0.5Hz General alarm |
T 12 |
 |
Alternating 800/1000Hz at 0.875Hz |
T 13 |
 |
Intermittent 2400Hz at 1Hz |
T 14 |
 |
Intermittent 800Hz 0.25s on 1s off |
T 15 |
 |
Continuous at 800Hz |
T 16 |
 |
Intermittent 660Hz 150mS on, 150mS off |
T 17 |
 |
Alternating 544Hz (100mS)/440Hz(400mS) |
T 18 |
 |
Intermittent 660Hz 1.8s on, 1.8s off |
T 19 |
 |
1400Hz to 1600Hz sweep up over 1s -1600Hz to 1400Hz sweep down over 0.5s |
T 20 |
 |
Continuous 660Hz |
T 21 |
 |
Alternating 554/440Hz at 1Hz |
T 22 |
 |
Intermittent 554Hz at 0.875Hz |
T 23 |
 |
800Hz pulsing at 2Hz |
T 24 |
 |
Sweeping 800/1000Hz at 50Hz |
T 25 |
 |
Sweeping 2400/2900Hz at 50Hz |
T 26 |
 |
Simulated bell sound |
T 27 |
 |
Continuous 554Hz |
T 28 |
 |
Continuous 440Hz |
T 29 |
 |
Sweeping 800/1000Hz at 7Hz |
T 30 |
 |
420Hz repeating 0.625s on, 0.625s off Australian alert signal |
T 31 |
 |
1200/500Hz at 1 Hz Prepare to Abandon Platform |
T 32 |
 |
Sweeping 500/1200Hz 3.75s on, 0.25s off 15Hz |
Country specific or custom tone configurations and alarm frequencies are available upon request. |