Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (4401)

MSA  10154080

$640.66     Availability: 7 Days
 Info/Quote Request
 Shipping Rates
 Volume discount
MSA 10154080
  • Overview
  • Benefits
  • Specs
  • Literature

MSA ALTAIR 2X Portable Single Gas Detector with XCell Sensor Technology for Chlorine (Cl2) Range 0-10 ppm. Low Alarm 0.5ppm, High Alarm 1ppm. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. IP67. cCSAus, ATEX and IEC Approved.

$640.66      

  Availability 7 Days  ]

Introducing the altair 2X gas detector from mSa; the first one or two gas detector that incorporates industry-leading Xcell Sensor technology to deliver unparalleled performance while drastically minimizing total cost of ownership, increasing durability and delivering enhanced worker safety, compliance and traceability.

The altair 2X is also the first portable gas detector to introduce revolutionary Xcell pulse technology. based on proven science and advanced patented sensor capabilities, the altair 2Xp detector delivers the world’s first stand-alone bump test. this allows a daily bump test to be performed without the need for calibration accessories or specific calibration gas.

XCell® Pulse Technology

With our patented* Xcell pulse technology, we have created a simple and inexpensive approach to bump testing. Years of scientific research, patented sensor interrogation technology and proprietary sensor response methodologies have delivered the world’s first gas detector with a stand-alone bump test. Simply put; the use of calibration accessories or bottled calibration gas is not required for bump testing the altair 2Xp gas detector.

How does it work? When the detector is turned on, it automatically begins an electronic pulse check that activates the sensor catalyst and electrolyte interaction and makes minor corrections against prior calibration values. next the user completes a flow check by exhaling toward the sensor inlet. an oxygen detector embedded in the sensor, that is only active during the pulse and flow check, detects the drop in oxygen content of exhaled breath. if both of these checks pass, the detector passes the bump test.

Lower Total Cost of Ownership

MSA’s industry leading technology combined with product durability means that the altair 2X gas detector provides a lower total cost of ownership than competitive instruments and will pay for itself quickly.

Built tough

Like all mSa detectors, altair 2X is built for durability and designed for the work that is being completed.

  • Withstands extreme impacts with rugged polycarbonate housing and passes 25-foot drop test
  • IP 67-rated altair 2X is both dust tight and water tight
  • Minimal rF interference
  • Full three-year warranty supports the entire instrument, including the sensors.
Reduced costs and Expense

Xcell Sensor response and recovery time reduces the gas consumption for calibration and gas bump tests (where applicable).

Increased productivity
  • Skip the gas line! – the stand-alone bump test on the altair 2Xp means that you will be spending more time doing the job and less time waiting in line or conducting bump tests. Spending less time at the bump station means less down time and more time producing!
  • Faster bump tests, easy compliance and product reliability means you can get to work faster and safer!

Technical Specifications
Size 3.5" l x 2.125" W x 1.25" d (no clip)
Weight 4 oz (113 g) w/ clip
Housing Rugged rubberized armor
Ingress protection IP67
Drop test 25 feet
Handling One-handed, one-button operation
Bump test indicators Pass: green LED flash & checkmark
Fail or expiration: red LED flash only
Audible alarm 95 db @ 1 foot
Visual alarm Ultra-bright LEDs
Vibrating alarm Standard
Display Large-character monochrome LCD
Backlight 10s backlight w/ adjustable timeout
Battery Replaceable lithium battery
Extended temp. range -20° C to +50° C
Extreme range -40° C to +60° C
Data log 2X/2Xp: > 150 hrs
2Xt: > 100 hrs
Event log 75 events
Standard Warranty Chassis & electronics: 3 years
Cl2 & nH3 sensors: 2 years
All other sensors: 3 years
Does not cover consumable parts.
Certifications/Approvals
USA cCSAus Class I Div 1 Groups A, B, C, D
Class II Div 1 Groups E, F, G Class III
Tamb = -40c to +60c t4
USA: ul 913 7th Edition
Canada: CSA 22.2 No. 157
ATEX FTZU II 2G Ex ia IIC T4 Gb -40C to +60C
IEC/AUSTRALIA/NEW ZEALAND FTZU Ex ia IIC T4 Gb -40C to +60C


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE :    32 Items found.
M001-0004-000
(5995)

MPOWER  M001-0004-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine (Cl2) 0-50ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$298.00 
BWS_-C-Y
(6384)

BW  BWS-C-Y

BW Solo Serviceable Single-gas Detector for Chlorine (Cl2) 0-50 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$399.50 
A-ALT-PRO-10076716
(1658)

MSA  A-ALT-PRO-10076716

MSA ALTAIR Pro Portable Single-gas Detector for Chlorine (Cl2) 0-20 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 0.5 ppm, High 1 ppm, STEL 1 ppm, TWA 0.5 ppm *** Discontinued, replaced by 10154080 ***



$458.37 
G02-B610-100
(3021)

RAE  G02-B610-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Chlorine (Cl2) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
20100022
(6658)

DEGA  20100022

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Chlorine (Cl2) with range 0-20ppm or 0-200ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$552.96 
20100023
(6478)

DEGA  20100023

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Chloride (Cl2) with range 0-200ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$552.96 
SPSTAXL1
(1482)

HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

Configure

$600.63 
30100016
(6522)

DEGA  30100016

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Chlorine (Cl2) with range 0-20ppm or 0-200ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$691.20 
20100116
(6667)

DEGA  20100116

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Chlorine (Cl2) with range 0-20ppm or 0-200ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$737.28 
364-455-01-365-782-11
(6151)

DELPHIAN  364-455-01-365-782-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Chlorine (Cl2) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$758.40 
GG-CL2-B-5
(2962)

CALIBRATION TECHNOLOGIES  GG-CL2-B-5

CTI GasGuard Cl2 Chlorine Electrochemical Sensor (0-5 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$819.00 
2106B1410
(1456)

HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$848.72 
30100105
(6537)

DEGA  30100105

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Chlorine (Cl2) with range 0-20ppm or 0-200ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$875.52 
GDS-49-3-12-02
(160)

GDS  GDS-49-3-12-02

GDS GDS-49 Remote Gas Detector Transmitter with stainless steel sensor head (non-XP) configured for Chlorine (CL2) with range 0-5 to 0-50 ppm. 2-Wire 4-20 mA transmitter.

Configure

$885.00 
GG-CL2-5-EXP
(5977)

CALIBRATION TECHNOLOGIES  GG-CL2-5-EXP

CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,010.10 
EX-CL2-5P-O
(6017)

MACURCO  EX-CL2-5P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Chlorine (CL2) 0-5ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,112.53 
SPXCDULNL2
(1898)

HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2.

Configure

$1,214.32 
ITRANS2-1720000
(6287)

OLDHAM  ITRANS2-1720000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Chlorine (Cl2) 0.2-99.9 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

S3KUL2-XNXXSL1SS
(687)

HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE (CI2) with electrochemical sensor, 2-wire 4-20mA loop, 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

Configure

$1,324.80 
100-0008-A1/100-0015-Cl2
(4750)

ESP SAFETY  100-0008-A1/100-0015-Cl2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL 2 certification.

Configure

$1,401.60 
Page: 1 | 2 | All