Notifier Fcm-1-rel | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   FCM-1-REL

SKU# (4143)
NOTIFIER FCM-1-REL
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.

Please Email us your request for quote   

   4 Weeks  ]

The FCM-1-REL Releasing Control Module is specifically designed for fire suppression releasing applications in FlashScan® systems. Power to the release agent solenoid(s) runs through the module for full-time monitoring and supervision.

The FCM-1-REL Releasing Control Module uses a redundant protocol; the module must be armed with a pair of signals in order to activate. It will then enter a 3-second window awaiting a pair of confirmation signals. If no confirmation is received, the module will automatically reset. It also supervises the wiring to the connected load and reports the status to the panel as NORMAL, OPEN, or SHORT CIRCUIT. The module has two pairs of output termination points available for fault-tolerant wiring and a panel-controlled LED indicator. The module may be connected to either one 24VDC solenoid or up to two 12VDC solenoids (in series). To ensure proper operation, this module shall be connected to a compatible Notifier system control panel only (list available from Notifier). In addition, please refer to Notifier Device Compatibility Doc- ument PN 15378 for the list of compatible solenoids.

NOTE: FCM-1-REL is required for all new FlashScan-mode releasing applications with NFS2-3030 (version 14.0 or higher), NFS2-640 (version 12.0 or higher) and NFS-320(E)(C) (version 12.0 or higher) panels. Use FCM-1 for releasing applications on NFS-640, NFS-3030, and all CLIP mode panels.

FEATURES

  • Redundant protocol for added protection
  • Configurable for Class A or Class B operation
  • External supply voltage monitoring
  • Can power one 24V or two 12V solenoids
  • SEMS screws for easing wiring
  • Panel controlled status LED
  • Analog communications
  • Rotary address switches
  • Low standby current
  • Mounts in standard 4" (10.16 cm) junction box
  • FlashScan operation
Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listings may be in process. Consult factory for latest listing status.

  • UL: S635
  • ULC: (FCM-1-RELA)
  • FM Approved
  • CSFM: 7300-0028:0249

FCM-1-REL(A) SPECIFICATIONS
GENERAL SPECIFICATIONS
Operating voltage: 15 to 32 VDC
Communication Line Loop Impedance: 40 Ohm max.
Temperature Range: 14°F to 140°F (-10° to 60°C)
Relative Humidity: 10% to 95% noncondensing
Shipping Weight: 5.5 oz (156 g)
Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply.
Dimensions: 4.275" W × 4.675" H × 1.400" D (10.86 cm W × 11.87 cm H × 3.56 cm D)
SLC
Average Operating Current: 700 μA max @ 24 VDC (one communication every 5 sec. with LED enabled)
Maximum Activation Current: 9.0 mA (LED on)
EXTERNAL SUPPLY
Normal Operating Voltage: 24 VDC Nominal
Maximum Line Loss: 2.3 VDC (total allowable loss from power supply to module and from module to solenoid)
Minimum Operating Voltage to Activate Solenoid: 18 VDC (at solenoid)
Standby Current: 6.4 mA
Activation Current: 10 mA
SOLENOID
Supervisory Loop Voltage: 3.3 V
Supervisory Loop Current (Normal) 30mA
Maximum Activation Current: 2 A
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
MMF-300
(7242)

NOTIFIER  MMF-300

Notifier MMF-300 Addressable Monitor Module for supervising circuits of dry-contact input devices. Powered by two-wire SLC loop. 15-32 VDC. UL and FM listed.



 
RTS151KEY
(7241)

NOTIFIER  RTS151KEY

Notifier RTS151KEY automatic remote test station for duct smoke detectors. Includes key and status indicator.



 
MMF-301
(7238)

NOTIFIER  MMF-301

Notifier MMF-301 Addressable Mini-Monitor Module for use in intelligent, two-wire using rotary switches. 15-32 VDC.



 
CRF-300
(7236)

NOTIFIER  CRF-300

Notifier CRF-300 Addressable Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM and MEA Approved.



 
CMF-300
(7243)

NOTIFIER  CMF-300

Notifier CMF-300 Addressable Control Module for providing intelligent control panels a circuit for notification. 15-32 VDC. ULC listed.



 
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

HWL-LF
(7065)

NOTIFIER  HWL-LF

Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 