RAE 059-D100-000
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

UltraRAE 3000 PGM-7360 Portable Handheld Compound-Specific Volatile organic compund (VOC) 9.8/10.6/11.7 eV 0-9999ppm Detector with photoionization (PID) sensor. Optional Benzene or Butadiene sensors. Large graphic display. Audible alarm. Multi-language support. Optional Rechargeable Li-Ion battery version. IP65. UL, cUL (Class I Div 1), ATEX, CSA and IECEx approved.

Part# with Options:        059-D100-000
Price with Options:        5,184.15

Options:    

Lamps
(1) Lamps for UltraRAE 3000
Batteries
(2) Batteries for MiniRAE 3000 & UltraRAE 3000
Wireless and Certification
(3) Wireless and Certification for MiniRAE 3000 & UltraRAE 3000
Kits
(4) Kits for UltraRAE 3000

  Availability 2 Weeks  ]

The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID) extended range of 0.05 to 10,000 ppm in VOC mode and 50 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

  • Dual detection mode for total benzene exposure assessment: 60-second snap- shot or 15-minute STEL measurement
  • High sensitivity to benzene (as low as 50 ppb) provides a lower detection range for future benzene exposure limits
  • Lower risk of false alarms through advanced speciation method
  • Total VOC measurement mode with extended range of 0.05 to 10,000 ppm
Key Features
  • Proven PID technology
    • 3-second response in VOC mode or 60 seconds in compound-specific mode
    • Extended range up to 10,000 ppm (in VOC mode) with improved linearity
    • Built-in humidity sensor
    • Automatic temperature-controlled sampling time calculation
    • Highly specific readings, combining a 9.8eV UV lamp and RAE-Sep TM benzene tube
  • New sampling probe design provides instant tube-breakthrough visibility
  • Versatile VOC or Benzene-Specific modes
  • Real-time wireless with built-in Bluetooth and optional RAELink3 portable modem
  • Integrated RAE Systems Correction Factors list for more than 200 compounds
Easy to Use
  • Large graphic display
  • Multi-language support
  • Easy access to lamp, sensor and battery in seconds without tools
Low Cost of Ownership
  • Inexpensive analysis using low-cost RAE-Sep tubes
Applications
  • Confined space entry pre-screening during refinery and plant maintenance
  • Hazardous material response
  • Marine spill response
  • Refinery down-stream monitoring
  • Plant overhaul

Sensor Specifications
Gas Monitor Range Resolution Response Time (T90)
VOCs 0 to 99.99 ppm 0.05 ppm < 3 sec
100 to 999.9 ppm 0.1 ppm < 3 sec
1000 to 9999 ppm 1 ppm < 3 sec
Benzene 0 to 200 ppm 0.05 ppm < 60 sec
Butadiene 0 to 200 ppm 0.05 ppm < 60 sec
Specifications
Size 10" L x 3.0" W x 2.5" H (25.5 x 7.6 x 6.4 cm)
Weight 26 oz (738 g)
Sensors Photoionization sensor with standard 9.8 eV or optional 10.6 eV or 11.7 eV lamps
Battery Rechargeable, external field-replaceable Lithium-Ion battery pack
Alkaline battery adapter
Operating Hours 16 hours of operation
Display Graphic 4 lines, 28 x 43mm
Keypad 1 operation and 2 programming keys, 1 flashlight on/off button
Direct Readout VOCs as ppm by volume
High and low values
STEL and TWA
Battery and shutdown voltage
Date, time, temperature
Alarms 95dB buzzer (at 12"/30 cm) and flashing red LED to indicate exceeded preset limits
High: 3 beeps and flashes per second
Low: 2 beeps and flashes per second
STEL and TWA: 1 beep and flash per second
Alarms latching with manual override or automatic reset
Additional diagnostic alarm and display message for low battery and pump stall
EMI/RFI Highly resistant to EMI/RFI. Compliant with EMC directive (2004/108/EC); R & TTE directive (1999/5/EC)
IP Rating IP-65, unit running
Datalogging Standard 6 months at one-minute intervals
Calibration 2-point or 3-point calibration for zero and span. Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates
Sampling Pump Internal, integrated flow rate at 400 cc/min
Sample from 100' (30m) horizontally and vertically
Low Flow Alarm Auto shut-off pump at low-flow condition
Communication Download data and upload instrument setup from PC through charging cradle
Wireless data transmission through built-in Bluetooth TM
Frequency for RAELink3 Optional Modem 902 to 928 MHz (license-free), 2.400 to 2.4835 GHz (license-free), 433 MHz, 869 MHz
Wireless Network ProRAE Guardian Real-Time Wireless Safety System
Wireless Frequency ISM license-free bands
Wireless Range (Typical) UltraRAE 3000 to RAELink3 or RAELink3 Z1 modems ~ 33 feet (10 meters)
Hazard Area Approval US and Canada: CSAus , Classified as Intrinsically Safe for use in Class I, Division 1 Groups A, B, C, D
Europe: ATEX II 2G EEx ia IIC T4
IECEx CSA 10.0005 Ex ia IIC/IIB GbT4
Operating Temperature -4° to 122°F (-20° to 50°C)
Humidity 0% to 95% relative humidity (non-condensing)
Attachments Durable bright red rubber boot
Warranty 3 years for 10.6 eV lamp, 1 year for 9.8. eV lamp, pump, battery, sensor and instrument

  • ACCESSORIES > RAE WIRELESS
    029-0505-000 RAE Systems RAELink3 Kit Host Computer (PC) Controller Module. RAELink3 Mesh enables RAE Systems personal gas and radiation detectors, and select 3rd party monitors to communicate wirelessly with ProRAE Guardian safety monitoring software in real time. Li ..

  • ACCESSORIES > RAE WIRELESS
    029-0695-000 RAE Systems RAELink3 Mesh Modem Kit, portable Wireless Modem with GPS. RAELink3 Mesh enables RAE Systems personal gas and radiation detectors, and select 3rd party monitors to communicate wirelessly with ProRAE Guardian safety monitoring software in real ..

  • ACCESSORIES > RAE WIRELESS
    S01-1000-000 RAE Systems ProRAE host computer (PC) Guardian License - Tier 1 (ToxiRAE Pro Family, QRAE 3) ..

  • ACCESSORIES > RAE WIRELESS
    S01-A120-200 RAE Systems ProRAE Guardian Software CD ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> VOC PID :    23 Items found.
20100073
(6660)

DEGA  20100073

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Volatile Organic Compound (VOC) with range 0-20ppm (high sensitive). RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$599.04 
30100067
(6702)

DEGA  30100067

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Volatile Organic Compound (VOC) with range 0-20ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$737.28 
20100167
(6685)

DEGA  20100167

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Volatile Organic Compound (VOC) with range 0-20ppm (high sensitive). RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
30100156
(6709)

DEGA  30100156

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Volatile Organic Compound (VOC) with range 0-20ppm (high sensitive). Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$921.60 
20100095
(6496)

DEGA  20100095

DEGA NB III Gas Detection Transmitter for Volatile Organic Compounds (VOC) with PID Sensor for Acetone (C3H6O), Gasoline/Petrol vapours, Butane (C4H10), Ethanol (C2H5OH), Isopropyl alcohol (C3H8O), Butanon (C4H8O), Styrene (C8H8) or Toluene (C7H8) with range 0-4000 ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$1,036.80 
20100189
(6696)

DEGA  20100189

DEGA NB III LCD Gas Detection Transmitter with PID Sensor for Volatile Organic Compounds (VOC) with range 0-4000ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$1,244.16 
30100089
(6507)

DEGA  30100089

DEGA NS II Gas Detection Transmitter for Volatile Organic Compounds (VOC) with PID Sensor for Ethanol (C2H5OH), Acetone (C3H6O), Isopropyl alcohol (C3H8O), Toluene (C7H8), Styrene (C8H8), Butanon (C4H8O), Butane (C4H10) or Gasoline/Petrol vapours with range 0-5000 ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$1,267.20 
30100178
(6539)

DEGA  30100178

DEGA NS II LCD RE Gas Detector for Volatile Organic Compounds (VOC) with PID Sensor for Gasoline/Petrol vapours, Ethanol (C2H5OH), Acetone (C3H6O), Isopropyl Alcohol (C3H8O), Butanone (C4H8O), Toluene (C7H8), Styrene (C8H8), Butane (C4H10) with range 0-5000ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$1,497.60 
GDS-48-1-61-06
(347)

GDS  GDS-48-1-61-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Photoionization Detector (PID) for VOC (Volatile Organic Compounds). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.

Configure

$1,695.00 
G02-B000-000
(3012)

RAE  G02-B000-000

ToxiRAE Pro PID PGM-1800 Personal portable Monitor For Volatile Organic Compounds (Detects over 300 VOCs) with replaceable sensors, fan, filter and battery. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Rechargeable Li-ion battery, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. Wireless-capable option.

Configure

$1,737.55 
GMII-00-000-00/01-061-05/0-0
(609)

GDS  GMII-00-000-00/01-061-05/0-0

GDS GASMAX II PID 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$2,445.00 
M011-0004-000
(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm. Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless modem and pump. Includes Lithium-ion battery and USB Micro charger. Backlight display. Stainless steel housing. IP66/IP67. UL approval for Class I Div 1.

Configure

$2,610.00 
PTLSLBMR-0000
(5956)

ION SCIENCE  PTLSLBMR-0000

Ion Science Tiger LT handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, backlit keypad and data logger. ATEX, IECEx, UL and CSA approvals.

Configure

$2,704.80 
059-A110-000
(4131)

RAE  059-A110-000

MiniRAE Lite PGM-7300 Portable Handheld Volatile organic compund (VOC) 10.6 eV 0-5000ppm Detector with photoionization (PID) sensor. Field-interchangeable battery pack. Display and flashlight. Audible and visual alarms. Multi-language support. IP65.

Configure

$2,719.85 
GMCX-01-61-05/00-00-00/0
(3311)

GDS  GMCX-01-61-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,875.00 
GMIIx-00-000-00/01-061-05/1-0900
(1856)

GDS  GMIIx-00-000-00/01-061-05/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$3,084.94 
C2-01-061-05/00-000-00/0-0-0-0-0/0-0
(382)

GDS  C2-01-061-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with PID (Photoionization Detector) integrated sensor for VOC with range 0-50 to 0-300 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Configure

$3,085.00 
059-B100-000
(4132)

RAE  059-B100-000

MiniRAE 3000 PGM-7320 Portable Handheld Volatile organic compund (VOC) 10.6/9.8/11.7 eV 0-15000ppm Detector with photoionization (PID) sensor. Big graphic display and Flashlight. Audible and visual alarms. Multi-language support. Optional Rechargeable Li-Ion battery and Wireless versions. IP65/IP67. UL, cUL (Class I Div 1) and ATEX approved.

Configure

$3,932.05 
967-P15520-010
(6066)

DETCON  967-P15520-010

Detcon PI-700 Universal "Smart" Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10ppm to 0-5000ppm. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals.

FAXSXBXX-3000D
(5955)

ION SCIENCE  FAXSXBXX-3000D

Ion Science Falco Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. PID sensor. Pumped or diffused versions available. Includes Multi-coloured status display and long-life lamp. ATEX, IECEx, UL and CSA approvals.

Configure

$3,988.60 