Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (4069)

GDS  GM/EC-01-34-02

DETECTORS / GAS DETECTORS
PHOSPHINE

$1,295.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GM/EC-01-34-02 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head explosion proof (XP) configured for Phosphine (PH3) with range 0-5 to 0-10 ppm, 4-20 mA output transmitter.

Part# with Options:        GM/EC-01-34-02
Price with Options:        1,295.00

Options:    

Sensor Head
(1) Sensor Head for GDS GM/EC
Gas Range
(2) Gas Range for GDS (0-5, 0-10)
Enclosure
(3) Stainless Steel Enclosure for GDS
Tag
(4) Tag for GDS

  Availability 2 Weeks  ]

The GASMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The GASMAX EC support all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. In addition, GDS Corp Smart Sen- sors enhance this capability by maintain- ing their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX EC constantly tracks sensor performance and calculates an estimate of sensor life remaining. Built-in fault detection circuity constantly monitors the sensor for correct operation.

Advanced User Interface

The highly visible graphic display and flashing alarm LEDs constantly show alarm status, calibrated engineering values and a programmable tag name, plus a trend screen shows alarm levels and a graph of the most recent 30 minutes.

An internal real-time clock and event log time-stamp up to 300 calibration and alarm events for later review. Taking advantage of the high-resolution graphic display, an easy-to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Explosion-Proof or Intrinsically Safe

The GASMAX EC is CSA certified for use in Div 1 & Div 2 hazardous areas and can be installed as Explosion Proof (with stainless steel sensor head) or Intrinsi- cally Safe (with aluminum sensor head) using appropriate wiring techniques and an Intrinsically Safe barrier. See notes on IS installation on back. An ATEX certi- fied version for XP installations is also available.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • For combustible applications, see the GASMAX II gas monitor

Note: Sensor Heads 3, 4 and 8 require INTRINSICALLY SAFE (IS) installations in hazardous locations. IS installations require an IS barrier (#10-0263 MTL 7787P+) or equivalent that must be mounted in an area designated as Non-hazardous.

GASMAX EC SPECIFICATIONS
Power Input: 10-30VDC at less than 0.75 watts in 2-wire 4-20mA configuration
Display 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Input Accepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration Range Zero = +/- 15% of range with 0.1% resolution
Span = Gain adjustment of 0.5 to 2.0 with 0.1% resolution
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp -25°C to +60°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D. Intrinsically safe.
IMPORTANT: Intrinsically Safe installations require IS barrier #10-0263 (MTL 7787P+) or equivalent.
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0203 GDS Sensor calibration cup for stainless steel / aluminum sensor heads ..

  • BARRIERS > GDS GASMAX II, GASMAX EC GAS MONITOR
    10-0263 GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PHOSPHINE :    16 Items found.
M001-0016-000
(6007)

MPOWER  M001-0016-000

mPower UNI MP100 Portable Single Gas Detector for detection of Phosphine (PH3) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$298.00 
BWS_-P-Y
(6394)

BW  BWS-P-Y

Honeywell BW Solo Serviceable Single-gas Detector for Phosphine (PH3) 0-5 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$413.60 
GAXT-P-DL
(486)

BW  GAXT-P-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Phosphine (PH3) 0-5.0 ppm.

Configure

$551.76 
G02-B910-100
(3024)

RAE  G02-B910-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Phosphine (PH3) 0-20 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
GDS-49-1-34-02
(4075)

GDS  GDS-49-1-34-02

GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Phosphine (PH3) with range 0-5 to 0-10 ppm, Explosion Proof (XP). 2-Wire 4-20 mA transmitter.

Configure

$745.00 
961-200026-005G
(6374)

DETCON  961-200026-005G

Detcon DM-100-PH3 Electrochemical Phosphine (PH3) 0-5ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ITRANS2-1K70000
(6294)

OLDHAM  ITRANS2-1K70000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Phosphine (PH3) 0-1 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

S3KUL2-XNXXSP1SS
(698)

HONEYWELL  S3KUL2-XNXXSP1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring PHOSPHINE (PH3) with electrochemical sensor, 2-wire 4-20mA loop, 0-1.2ppm

Configure

$1,396.01 
GMII-01-034-02/00-000-00/0-0
(4065)

GDS  GMII-01-034-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Phosphine (PH3) with range 0-5 to 0-10 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,465.00 
XNXUTAENNNNN-XNXXSP1SS
(850)

HONEYWELL  XNXUTAENNNNN-XNXXSP1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Phosphine (PH3) 0-1.2ppm compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,727.54 
967-192090-005
(6098)

DETCON  967-192090-005

Detcon DM-700-PH3 Electrochemical "Smart" Phosphine (PH3) 0-5 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

EX-PH3-1P-O
(6036)

MACURCO  EX-PH3-1P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Phosphine (PH3) 0-1ppm or 0-5ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,788.15 
GMCX-01-34-02/00-00-00/0
(4067)

GDS  GMCX-01-34-02/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Phosphine (PH3) with range 0-5 to 0-10 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$1,960.00 
GM/TX/01-34-02/00-00-00/1-0900
(4702)

GDS  GM/TX/01-34-02/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Phosphine (PH3) with range 0-5 or 0-10 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,085.00 
ITR2SA-1K70000
(6310)

OLDHAM  ITR2SA-1K70000

Oldham iTrans 2 Stand-Alone Gas Detector with electrochemical smart sensor for Phosphine (PH3) 0-1 ppm. 4-20mA. NEMA 4X/IP66 Enclosure to be installed in safe area only (Non-Explosion Proof, no relays nor Modbus/HART available)



 
C2-20-034-02/00-000-00/0-0-0-0-0/0-0
(4706)

GDS  C2-20-034-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Phosphine (PH3) with range 0-5 to 0-10 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Configure

$2,210.00