Macurco Dvp-120m | 12-99-channel Low Cost | Multi-point Controllers | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   DVP-120M

MACURCO DVP-120M

GAS DETECTION CONTROLLERS / MULTI-POINT CONTROLLERS
12-99-CHANNEL LOW COST

$1,444.88  [2 Days]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Macurco DVP-120M Addressable Detection and Ventilation Panel. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on three channels of 29 sensors per channel. Features 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

DVP-120M   
1,444.88

LADBS Sticker
LADBS detectors require Macurco DVP-120 LADBS alarm panels

   2 Days  ]

The DVP-120M is a Modbus-Enabled Detection and Ventilation Panel with up to 87 Modbus addressable sensors on three channels of 29 sensors per channel, plus the original 12 analog 4-20mA sensor channels. The DVP-120M increases the capacity of the DVP-120 from 12 detectors to 99. System wiring includes 4-20mA current loop and RS-485 serial interface.

When the DVP-120M is in alarm the internal buzzer will sound, the alarm lamp will be red and the LCD will show the sensor type and channel number. The DVP-120M has an externally visible LCD display showing the status of each transducer and relay. You can navigate this display by entering the channel # or scrolling through the channels with the key pad.

Features
  • External keypad for selection of the transducer/alarm display and configuration
  • Externally visible LCD display showing the status of each transducer and relay
  • Externally visible system, alarm and relay status indicators
  • Compatible with all Macurco 6-Series and 12-Series gas sensors
  • Twelve analog (current loop) input channels
  • Three 10A, 240 VAC SPDT fan/alarm relays
  • Drivers for external Horn and Strobe
  • Fail-safe operation can be implemented
  • Lockable NEMA 1 type enclosure
  • Modular input and output connectors
  • ETL Listed to UL 508A, CAN/CSA-C22.2 No. 14-13, LADBS Approved
  • Up to three ventilation control zones can be defined
  • Each zone can be controlled based on transducer signals and/or time of day
  • Each relay is configurable for delay before activation and minimum on tim
  • 12 analog (4-20mA) input channels.
  • 87 addressable sensors on three channels of 29 sensors per channel
  • External power supply is required for addressable sensors
Applications

Parking garages, loading docks, vehicle repair facilities, arenas, warehouses and other commercial applications

Installation & Connection

System wiring includes main power connection for the DVP-120M, 4-20mA current loop, RS-485 serial interface and 24VDC power connections between the remote detectors and the DVP-120M and the fan control and alarm connections from the DVP-120M to the building ventilation and automation systems. The DVP-120M control panel has three relays which can be used for ventilation fan control or alarm signaling. The ventilation control function operates independently from the alarm function. It provides the ability to configure the DVP-120M for control of one to three zones. Each zone can respond to gas levels at one or more of the sensors, with configurable rising and falling concentrations for each gas type. Each zone can also be controlled based on the time of day.

MRS-485 Modbus RS-485 Adapter

The Macurco MRS-485 adapter is an accessory used to convert the 4-20mA analog signal from Macurco 6-Series type detectors to a digital signal for use with multipoint addressable systems. The Macurco MRS-485 simply plugs into the back of the detector and a single screw fastens it in place. The MRS-485 accepts the 4-20mA output and is powered from the same connection as the detector. The MRS-485 has the ability to interface with the Macurco DVP-120M Modbus Enabled Detection and Ventilation Control Panel as well as Building Automation Systems or other control devices that accept Modbus communications.

DVP-120M Inside
DVP-120M RS-485 Modbus Master-Slave Network

DVP-120 Specifications
Size 10 x 12 x 2 inches
Shipping Weight 6.5 poundS
Power Input 100 - 240 VAC 1 amps
Output Control Relays 3
Relay Rating 16 amps / 240 volts
CO Transducer Range 0 - 250 ppm
NO Transducer Range 0 - 9 ppm
EX Transducer Range 0 - 10000 ppm
Relay Turn On Delay 0 - 15 minutes
Relay Turn Off Delay 0 - 15 minutes
Export Info
Harmonized Tariff Code (HTC)8531100045

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
MRS-485
(2947)

MACURCO  MRS-485

MACURCO Modbus RS-485 Slave Adapter for use with Macurco 6-Series gas leak detectors to convert the 4-20mA analog signal from Macurco 6-Series type detectors to a Modbus digital signal for use with multipoint addressable systems and control panels such as the DVP-120M. Plugs into the back of the detector.



$118.05 
(6048)

MACURCO  HS-SYNC

Macurco HS-SYNC Synchronization Module for use with multiple Macurco Horn & Strobe units.



$123.71 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$481.90 
CM-6
(637)

MACURCO  CM-6

MACURCO CM-6 low voltage gas detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1. Optional LADBS approval.

Configure

$481.90 
TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$648.99 
TX-6-HS
(2045)

MACURCO  TX-6-HS

Macurco TX-6-HS low voltage Gas Detector, Controller and Transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$648.99 
TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
DVP-120B
(6227)

MACURCO  DVP-120B

Macurco DVP-120B Addressable Detection and Ventilation Panel with BACnet MS/TP output. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on two channels and 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,752.43 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.