Gds C2-22-012-02/00-000-00/0-0-0-0-0/0-0 | Chlorine | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2-22-012-02/00-000-00/0-0-0-0-0/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Inquiry

The C2 Protector Display & Alarm Controller provides signal conditioning, display and alarm functions for one or two critical input variables.

Versatile

Designed to provide low-cost direct monitoring for one or two gas sensors or flame detectors, the C2 Protector controller offers a highly-integrated, complete solution for detection of hazardous conditions. Versatile input signal conditioning options allow direct connection of any GDS Corp electrochemical sensor, and local or remote support for any GDS Corp combustible, PID or infrared sensor. Both channels can be configured to accept analog inputs from sources such as the GDS-49 Sensor Transmitter, GDS-IR Point Infrared Gas Detector or any standard 4-20mA source.

Additional C2 options include 5A SPDT discrete relays, 4-20mA outputs, light stacks and audible annunciators.

One popular application for the C2 is as a dual gas detector equipped with one local combustible sensor and one local toxic sensor. Alternatively, two combustible locations may be monitored with one sensor local and another remote.

Real-Time Display

A large graphic LCD screen displays input data as calibrated engineering units, bargraphs or 30-minute trends. Three adjustable alarm levels per channel, combined with programmable relays with voting logic allows flexible control of beacons, horns and other warning devices. Highly visible red and yellow LEDs visually indicate alarm status at all times.

Digitally Connected

An optional RS-485 MODBUS® slave port allows multiple C2 controllers to be multi-dropped on a single data highway. The C2 Protector controller is also 100% compatible with the ProtectorHMI Visualization and Historian software that can monitor, display and record data from up to ten C1 Protector or C2 Protector controllers.

Reliability

The C2 Protector controller is CSA certified to CSA C22.2 No. 152 for combustibles and Class I, Division 2, Groups A, B, C, D for use in hazardous areas. An optional NEMA 7 enclosure allows use in Class I Div 1 areas. Up to twelve watts of 24 VDC power is available for auxiliary devices or transmitters.

FEATURES

  • Accepts one or two direct-connect local or remote sensors or 4-20mA
  • Large LCD display shows values, bar-graph and trend data
  • Two programmable 5A SPDT common relays for Alarm 1, Alarm 2, Horn or FAULT
  • Optional 6x relay board for perchannel SPDT contacts
  • Optional dual channel 4-20mA board for current loop output
  • Operates on either +24VDC or 117/240VAC 50/60Hz
  • ACK button silences HORN without affecting alarm relays
  • Relay voting logic reduces need for external hardware
  • Touch and magnetic keys for non-intrusive operation in XP areas
  • Pushbutton zero and span calibra tion for directly connected sensors
  • NEMA 4x approved for Class 1 Div 2 area without purge
  • MODBUS® slave port for easy interface from master devices
  • CSA certified to C22.2 No 152 for combustible gas detection and approved for Class 1, Div 2 Groups A, B, C, D
  • Manufactured in USA

C2 Protector SPECIFICATIONS
Power Input: 24VDC (12 Watt MAX) 85-240 VAC power supply included
Display Backlit 128x64 pixel LCD shows trend, bargraph and engineering units; flashing alarm LEDs indicate alarm status
Input Inputs available for dual catalytic bead LEL, dual toxic / O2, one each catalytic bead & toxic / O2, and dual 4-20mA
MODBUS I/O Optional slave mode RS-232 or RS-485 MODBUS interface
Relay Output Two common output relays configurable for A1, A2, FAIL & HORN ; 5A @ 30VDC / 240VAC resistive load
Analog Output Optional dual channel 4-20mA current loop. Max loop R is 800 ohms with nominal 24VDC
Audible Output Optional 100db alarm (NEMA 4X only)
Temp -25°C to +50°C operating
Housing NEMA 4X approved for Class 1 Div 2 Groups A, B, C, D
NEMA 7 wall-mount approved for Cls 1 Div 1 Groups B, C, D
Dimensions NEMA 4X Non-metallic: 11.25” x 13.31” x 7.25” (w-h-d)
NEMA 4X Painted or stainless: 9.84” x 13.65” x 6.2”
NEMA 7: 13” x 14.25” x 6.25”
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02;
UL 1604 / C22.2 No 213 (NEMA 4X = Div 2 Groups A, B, C, D;
NEMA 7 = Div 1 Groups B, C, D) EN55011 & EN61000 (CE Mark)
Warranty 2 years from date of purchase on electronics
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
10-0221/DUAL
(435)

RC SYSTEMS  10-0221/DUAL

RC Systems 4-20 mA 2-channel analog input board for ST-90 Dual Controllers



$268.83 
1200-0259
(3166)

GDS  1200-0259

GDS Gas Detector Calibration Gas Cylinder Chlorine (Cl2) 5ppm. Balance Nitrogen. 58L Aluminium Cylinder.

1200-0543
(3167)

GDS  1200-0543

GDS Gas Detector Calibration Gas Cylinder Chlorine (Cl2) 10ppm. Balance Nitrogen. 58L Aluminium Cylinder.

1200-0507
(3096)

GDS  1200-0507

GDS Gas Detector Calibration Gas Kit Chlorine (Cl2) 5 ppm. Balance Nitrogen. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0508
(3097)

GDS  1200-0508

GDS Gas Detector Calibration Gas Kit Chlorine (Cl2) 10 ppm. Balance Nitrogen. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

> CHLORINE :    23 Items found.
M001-0004-000
(5995)

MPOWER  M001-0004-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine (Cl2) 0-50ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
BWS1-C-Y
(6384)

BW  BWS1-C-Y

BW Solo Serviceable Single-gas Detector for Chlorine (Cl2) 0-50 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

364-455-01-365-782-11
(6151)

DELPHIAN  364-455-01-365-782-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Chlorine (Cl2) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-6924
(6810)

PROSENSE  PC3-6924

Prosense PC3-6924 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6934
(6785)

PROSENSE  P-6934

Prosense P-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXL1
(1482)

HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

Configure

$929.07 
PQN-6934-1/2
(6958)

PROSENSE  PQN-6934-1/2

Prosense PQN-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-CL2-B-5
(2962)

CALIBRATION TECHNOLOGIES  GG-CL2-B-5

CTI GasGuard Cl2 Chlorine Electrochemical Sensor (0-5 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
PQD-6934-1/2
(6746)

PROSENSE  PQD-6934-1/2

Prosense PQD-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
GG-CL2-5-EXP
(5977)

CALIBRATION TECHNOLOGIES  GG-CL2-5-EXP

CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
2106B1410
(1456)

HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,402.14 
100-0008-SS/100-0015-Cl2
(4750)

ESP SAFETY  100-0008-SS/100-0015-Cl2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
1100ALD-109014/01P-L0
(6910)

RC SYSTEMS  1100ALD-109014/01P-L0

RC Systems SenSmart 1100 gas detector for Chlorine (Cl) 0-1ppm to 0-50ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,528.57 
S3KUL2-XNXXSL1SS
(687)

HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE (Cl2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-5.0ppm, user adjustable (5.0 to 20.0ppm, 5.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,640.19 
41001AL-0-1012/0005P/L0
(7160)

RC SYSTEMS  41001AL-0-1012/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Chlorine (Cl2) 0-5 to 0-5000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,753.24 
51001AL-0-1012/0005P/L0
(7125)

RC SYSTEMS  51001AL-0-1012/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Chlorine (Cl2) 0-5 to 0-5000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
961-740026-010G
(6353)

DETCON  961-740026-010G

Detcon DM-100-CL2 Electrochemical Chlorine (Cl2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

SPXCDULNL2
(1898)

HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
967-747490-010
(6075)

DETCON  967-747490-010

Detcon DM-700-CL2 Electrochemical Smart Chlorine (CL2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

2100AL-0-9014/01P/L0
(118)

RC SYSTEMS  2100AL-0-9014/01P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Chlorine (Cl) 0-1ppm to 0-50ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,003.89 