Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (355)

GDS  C2-20-010-04/00-000-00/0-0-0-0-0/0-0

DETECTORS / GAS DETECTORS
OXYGEN

$2,175.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS C2-20-010-04/00-000-00/0-0-0-0-0/0-0
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Oxygen (O2) sensor with range 0-25% Vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Part# with Options:        C2-20-010-04/00-000-00/0-0-0-0-0/0-0
Price with Options:        2,175.00

Options:    

Sensor Head (Channel 1)
(1) Sensor Head for GDS C2 for non reactive gases 2
Relay Output
(2) Relay Output for GDS C2
Analog Output
(3) Analog Output for GDS C2
Digital Output
(4) Digital Output for GDS C2
Audible Alarm
(5) Audible Alarm for GDS C2
Visual Alarm
(6) Visual Alarm for GDS C2
Enclosure Options
(7) Enclosure Options GDS C2
ACK Button
(8) C1D2 Local ACK Button
ACK Button
(9) General Purpose ACK Button (C2)
2nd Input channel
(10) Second 4-20 mA or bridge input channel for GDS C2 controller
Power Supply
(11) Power Supply for GDS C2 controller
Requires extended enclosure

Availability 2 Weeks  ]

The C2 Protector Display & Alarm Controller provides signal conditioning, display and alarm functions for one or two critical input variables.

Versatile

Designed to provide low-cost direct monitoring for one or two gas sensors or flame detectors, the C2 Protector controller offers a highly-integrated, complete solution for detection of hazardous conditions. Versatile input signal conditioning options allow direct connection of any GDS Corp electrochemical sensor, and local or remote support for any GDS Corp combustible, PID or infrared sensor. Both channels can be configured to accept analog inputs from sources such as the GDS-49 Sensor Transmitter, GDS-IR Point Infrared Gas Detector or any standard 4-20mA source.

Additional C2 options include 5A SPDT discrete relays, 4-20mA outputs, light stacks and audible annunciators.

One popular application for the C2 is as a dual gas detector equipped with one local combustible sensor and one local toxic sensor. Alternatively, two combustible locations may be monitored with one sensor local and another remote.

Real-Time Display

A large graphic LCD screen displays input data as calibrated engineering units, bargraphs or 30-minute trends. Three adjustable alarm levels per channel, combined with programmable relays with voting logic allows flexible control of beacons, horns and other warning devices. Highly visible red and yellow LEDs visually indicate alarm status at all times.

Digitally Connected

An optional RS-485 MODBUS® slave port allows multiple C2 controllers to be multi-dropped on a single data highway. The C2 Protector controller is also 100% compatible with the ProtectorHMI Visualization and Historian software that can monitor, display and record data from up to ten C1 Protector or C2 Protector controllers.

Reliability

The C2 Protector controller is CSA certified to CSA C22.2 No. 152 for combustibles and Class I, Division 2, Groups A, B, C, D for use in hazardous areas. An optional NEMA 7 enclosure allows use in Class I Div 1 areas. Up to twelve watts of 24 VDC power is available for auxiliary devices or transmitters.

FEATURES

  • Accepts one or two direct-connect local or remote sensors or 4-20mA
  • Large LCD display shows values, bar-graph and trend data
  • Two programmable 5A SPDT common relays for Alarm 1, Alarm 2, Horn or FAULT
  • Optional 6x relay board for perchannel SPDT contacts
  • Optional dual channel 4-20mA board for current loop output
  • Operates on either +24VDC or 117/240VAC 50/60Hz
  • ACK button silences HORN without affecting alarm relays
  • Relay voting logic reduces need for external hardware
  • Touch and magnetic keys for non-intrusive operation in XP areas
  • Pushbutton zero and span calibra tion for directly connected sensors
  • NEMA 4x approved for Class 1 Div 2 area without purge
  • MODBUS® slave port for easy interface from master devices
  • CSA certified to C22.2 No 152 for combustible gas detection and approved for Class 1, Div 2 Groups A, B, C, D
  • Manufactured in USA

C2 Protector SPECIFICATIONS
Power Input: 24VDC (12 Watt MAX) 85-240 VAC power supply included
Display Backlit 128x64 pixel LCD shows trend, bargraph and engineering units; flashing alarm LEDs indicate alarm status
Input Inputs available for dual catalytic bead LEL, dual toxic / O2, one each catalytic bead & toxic / O2, and dual 4-20mA
MODBUS I/O Optional slave mode RS-232 or RS-485 MODBUS interface
Relay Output Two common output relays configurable for A1, A2, FAIL & HORN ; 5A @ 30VDC / 240VAC resistive load
Analog Output Optional dual channel 4-20mA current loop. Max loop R is 800 ohms with nominal 24VDC
Audible Output Optional 100db alarm (NEMA 4X only)
Temp -25°C to +50°C operating
Housing NEMA 4X approved for Class 1 Div 2 Groups A, B, C, D
NEMA 7 wall-mount approved for Cls 1 Div 1 Groups B, C, D
Dimensions NEMA 4X Non-metallic: 11.25” x 13.31” x 7.25” (w-h-d)
NEMA 4X Painted or stainless: 9.84” x 13.65” x 6.2”
NEMA 7: 13” x 14.25” x 6.25”
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02;
UL 1604 / C22.2 No 213 (NEMA 4X = Div 2 Groups A, B, C, D;
NEMA 7 = Div 1 Groups B, C, D) EN55011 & EN61000 (CE Mark)
Warranty 2 years from date of purchase on electronics
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-8110-R04 Electrochemical DELRIN Sensor configured for Oxygen (O2) with range 0-25%. For direct mount on TRANSMAX and C2 Controller. ..

  • BOARDS > GDS C2 CONTROLLER
    10-0221 GDS 4-20 mA dual channel analog output board for C2 Controllers ..

  • CALIBRATION GAS GDS > OXYGEN
    1200-0549 GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 8%. Balance Nitrogen. 103L Aluminium Cylinder. ..

  • CALIBRATION GAS GDS > OXYGEN
    1200-0550 GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 18%. Balance Nitrogen. 103L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > OXYGEN
    1200-0527 GDS Gas Detector Calibration Gas Kit Oxygen (O2) 8%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • CALIBRATION KITS GDS > OXYGEN
    1200-0528 GDS Gas Detector Calibration Gas Kit Oxygen (O2) 18%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> OXYGEN :    43 Items found.
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



$101.40 
M014-0003-000
(6334)

MPOWER  M014-0003-000

mPower UNI 321 Disposable Single Gas Detector for detection of Oxygen (O2) 0.1%-30%. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$106.40 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

Configure

$187.00 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$188.00 
10092523
(2650)

MSA  10092523

MSA ALTAIR Portable Single-gas Detector for Oxygen, alarms at 19.5% Vol. and 23% Vol. (O2) coupled with LED/audible/vibrating alarms. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class 1, Division 1, Groups A, B, C and D. 2 years.



$260.00 
BWS_-XL-Y
(6392)

BW  BWS-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$327.25 
0401065
(6477)

DEGA  0401065

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Oxygen (O2) with range 0-30%. 4-20mA 3-Wire and RS-485 outputs. IP54.



$351.90 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$357.20 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$365.92 
0402070
(6508)

DEGA  0402070

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Oxygen (O2) with range 0-30%. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$400.78 
G02-BE10-100
(3015)

RAE  G02-BE10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Oxygen (O2) 0-30% vol. with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$413.25 
10074137
(1638)

MSA  10074137

MSA ALTAIR Pro Portable Single-gas Detector for Oxygen (O2) 0-25% Vol. coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 19.50%, High 23.00%



$424.14 
SPSTAXO1
(1476)

HONEYWELL  SPSTAXO1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$461.03 
6302-0003
(6232)

BACHARACH  6302-0003

Bacharach MGS-410 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$472.50 
0407203
(6538)

DEGA  0407203

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Oxygen (O2) with range 0-30%. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$498.53 
6302-1003
(6242)

BACHARACH  6302-1003

Bacharach MGS-450 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$528.30 
SPC3-1195-200US
(2909)

INTEC  SPC3-1195-200US

Intec Controls PolyGard SPC3-1195 Sigle-Point Gas Detector for Oxygen (O2) 0-25% Vol, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified.



$610.48 
6302-4003
(6252)

BACHARACH  6302-4003

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$649.80 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

Configure

$658.76 
364-455-01-365-251-11
(6157)

DELPHIAN  364-455-01-365-251-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$681.60 
Page: 1 | 2 | 3 | All