Notifier Ncm-f | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   NCM-F

SKU# (3507)



NOTIFIER NCM-F
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

NCM-F   
Please Email us your request for quote   

Model

 4 Weeks  ]
2 Variants of base SKU

The Network Communications Module (NCM) provides NOTIFIER Intelligent Fire Alarm Control Panels, and NCA and NCA-2 Network Control Annunciators with a means to connect to NOTI•FIRE•NET™. Two types of NCM are available: NCM-W for connecting nodes with twisted-pair wire, and NCM-F for connecting nodes with fiber-optic cable

NCM-W Features
  • Supports twisted-pair wire medium.
  • NFPA Style 4 (Class B) operation or NFPA Style 7 (Class A) operation.
  • Two programmable data thresholds.
  • Transformer coupling provides electrical isolation between nodes.
  • Pluggable terminal wiring with strain relief.
  • Pluggable service connector (feeds signal directly through) in the
  • event that power must be removed from a node.
  • 312.5 Kbaud transmission rate.
  • Data is regenerated at each node.
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer.
  • Enables software and database upload/download over NOTI•FIRE•NET™.
  • Repeaters are available to increase signal.
  • Repeaters may be utilized to switch media type.
  • Up to 3,000 feet (914.4 m) between nodes in a point-to-point fashion (actual distance varies with wire quality).

NCM-W Interconnections: When wiring consecutive NCM-W boards, wiring may enter or exit at Port A or Port B. NCM-W port- to-port wiring is not polarity sensitive; use of Port A or Port B is arbitrary. An NCM-W may be connected to any of the following devices: MIB-W, MIB-WF, NAM-232W, NCM-W (in another panel), NCS-W network connection, RPT-W, RPT-WF.

NCM-W Switch Functions: The NCM-W provides two sets of switches to simplify network setup. Enable ground fault detection by setting “ON” switch SW103 (Channel A); switch SW101 (Chan- nel B). Activate on-board end-of-line resistors by setting “ON” switch SW100 (Channel A); switch 102 (Channel B). NOTE: Cor- rect configuration is dependent on network design; refer to the NOTI•FIRE•NET™ Network manual.

NCM-F Features
  • Supports fiber-optic medium.
  • NFPA Style 4 (Class B) or Style 7 (Class A) operation.
  • Data is immune to all environmental noise.
  • Optical isolation prevents ground loops.
  • NOTI•FIRE•NET™ Network fiber-optic medium.
  • Fiber type: 62.5/125 micrometers (multimode); or 50/125 micrometers (multimode).
  • Maximum attenuation is 8 dB with 62.5/125 μm fiber and 4.2 dB with 50/125 μm fiber.
  • Wavelength (1): 820 nanometers (use standard 850 nm fiber).
  • Connectors: ST® style.
  • 312.5 Kbaud transmission rate.
  • Data is regenerated at each node.
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer.
  • Enables software and database upload/download over NOTI•FIRE•NET™.
  • Repeaters are available to increase signal.
  • Repeaters may be utilized to switch media type.

NCM-F Interconnections: When wiring consecutive nodes/ repeaters, fiber cable must exit one board on Transmit (TX) and enter the next node/repeater on Receive (RX). The fiber-optic pair (RX, TX) from Port A of one node/repeater may be connected to either Port A or Port B of another node/repeater. An NCM-F may be connected to any of the following devices: MIB-F, MIB-WF, NAM-232F, another NCM-F, NCS-Fnetwork connection, RPT-F, RPT-WF.

MIXING WIRE AND FIBER ON THE SAME NETWORK

In some networks, it may be necessary to mix twisted-pair wire and fiber-optic cable. There are two solutions:

  • In any network, an RPT-WF may be used as an interface between wire and fiber.

In a network that uses an AFP1010 or AM2020, a MIB-WF may be used as the interface between wire and fiber.

MOUNTING

Both NCM-W and NCM-F can be installed in any standard chassis such as the CHS-4L, CHS-M2, CHS-M3 or CHS-4N (see panel sheets). Additionally, the NCM-W can be door-mounted on the ADP-4B dress panel on a single-space blank plate (BMP-1) for mounting in an CAB-4 Series cabinet.

Agency Listings and Approvals

The following listings and approvals apply to the NCM. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC Listed: S635
  • CSFM: 7165-0028:0224 (NFS2-3030), 7165-0028:0243 (NFS-320, NFS2-640)
  • FM approved
  • MEA approved
  • FDNY: COA#6306, COA#6212

Common Specifications
Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F).
Power supply: 24 VDC @ 110 mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.