Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (3401)

GDS  TM-EC-48-26-01-0

DETECTORS / GAS DETECTORS
PHOSGENE

$1,240.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS TM-EC-48-26-01-0
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head (optional DELRIN) and integrated sensor configured for Phosgene (COCL2) for range 0-1, 0-2 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

Part# with Options:        TM-EC-48-26-01-0
Price with Options:        1,240.00

Options:    

Sensor Head
(1) Sensor Head for GDS TMEC
DELDRIN sensor heads do not utilize Smart Sensor interface
Gas Range
(2) Gas Range for GDS (0-1, 0-2)
Conduit Entry Options
(3) Conduit Entry Options for GDS TMII

  Availability 2 Weeks  ]

Features

  • High quality gas deteciton for general purpose areas
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Fault supervision circuitry detects failed sensor & transmits warning
  • For combustible applications, see the TRANSMAX II gas monitor
  • Manufactured in USA

The TRANSMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The TRANSMAX EC supports all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more (see chart on back). Disposable DELRIN sensor heads with integrated sensors make maintenance easy. Fault detection circuity constantly monitors sensor inputs for missing or faulty sensors.The TRANSMAX EC maintains a record of sensor calibration data and calculates and displays an estimate of sensor life remain- ing at the conclusion of each calibration cycle.

Advanced User Interface

The highly visible graphic LCD display shows the latest reading in large (0.6”) digits, engineering units and program- mable tag name. Flashing LEDs indicate alarm status, a unique feature among loop-powered devices. Activating the NEXT key switches to a trend screen that graphically displays alarm levels and a record of the most recent 30 minute trend. A built-in, prompted calibration procedure simplifies periodic maintenance needs.

An internal real-time clock and event log time-stamp up to 300 alarm events for later review. Taking advantage of the high-resolution graphic display, an easy- to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without opening the enclosure.

Enhanced Security

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Designed for General Purpose Areas

The TRANSMAX EC is designed spe- cifically for general purpose areas where highly reliable gas detection is required. The enclosure is rated NEMA 4X and IP66/67 for outdoor use. A splash guard is available for the sensor if directed water spray is expected.

Power Input 10-30VDC at less than 0.75 watts
Display64 x 128 pixel LCD with 30-minute trend, bargraph and engi- neering units display.
InputAccepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration RangeZero = +/- 15% of range with 0.1% resolution
Accuracy+/- 5% of full scale range (typical)
Standard OutputStandard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp-25°C to +60°C (see sensor limitations)
HousingPolycarbonate housing with transparent cover. Stainless steel screws. Rated IP66/IP67
DimensionsWidth 4.87” (124mm), Height 6” (152mm), Depth 3.75” (95mm)
Shipping weight 3.5 pounds (1.6 kg)
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9526-R01 Electrochemical Smart Sensor configured for Phosgene (COCL2) with range 0-1/0-2 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GA ..

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0301 GDS Sensor calibration cup for DELRIN sensor heads ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > PHOSGENE :    8 Items found.
8326360
(6326)

DRAEGER  8326360

Draeger Pac 8000 Personal Single-Gas Detector for Phosgene (COCL2) 0-10ppm. Includes 360° alarm signal, large display, data and event logger, battery and a replaceable filter membrane for water and dust protection. IP68. CSA, IECEx, ATEX and CE approvals.



$759.92 
TMII-48-26-01/00-00-00/0-0
(1667)

GDS  TMII-48-26-01/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head with integrated sensor configured for Phosgene (COCL2) for range 0-1, 0-2 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$1,365.00 
GM/EC-03-26-01
(1645)

GDS  GM/EC-03-26-01

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Phosgene (COCL2) with range 0-1 to 0-2 ppm, 4-20 mA output transmitter.

Configure

$1,525.00 
GMII-03-026-01/00-000-00/0-0
(1652)

GDS  GMII-03-026-01/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Phosgene (COCL2) with range 0-1 to 0-2 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,695.00 
GM/ECx-03-26-01-1-0900
(1824)

GDS  GM/ECx-03-26-01-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Phosgene (COCL2) with range 0-1, 0-2 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$2,075.00 
GMCX-03-26-01/00-00-00/0
(3300)

GDS  GMCX-03-26-01/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Phosgene (COCL2) with range 0-1 to 0-2 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. For non-clasified areas only

Configure

$2,190.00 
GMIIx-03-026-01/00-000-00/1-0900
(1847)

GDS  GMIIx-03-026-01/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Phosgene (COCL2) with range 0-1, 0-2 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,281.57 
GM/TX/03-26-01/00-00-00/1-0900
(3436)

GDS  GM/TX/03-26-01/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head (non-XP) and integrated sensor configured for Phosgene (COCL2) with range 0-1 to 0-2 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,315.00