GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

GDS-58DXP-0-110-06-15-04/0-0   
Please Email us your request for quote   

Inlet Filter
Sensor Type (GDS-IR channel)
Gas Range
Local Relay Option
Mounting Options
Enclosure Options
Tag
Enclosure heater
Duct mount probe

   3 Weeks  ]
251 Variants of base SKU / 30 Shown

The GDS-58NXP sample draw system is an ideal solution for applications where ambient conditions are unsuitable for traditional ambient sensors, or where access to an ambient sensor would be inconvenient or dangerous. The GDS-58NXP sample draw features the new GASMAX CX gas monitor with DigitalSensor technology and advanced Ethernet / MODBUS communications. Together with a fully integrated long-life brushless sample pump, adjustable flow meter and low flow warning switch, the highly reliable GDS-58NXP can monitor locations up to 500 feet away.

GASMAX CX Gas Monitor

The new GASMAX CX dual channel gas monitor supports new GDS Corp Digital Sensors for toxic and combustible gases as well as volatile organics and inert gases such as CO 2 . The high contrast full color graphic display shows system status, gas values, programmable tag name and engineering units under full daylight conditions. Unlike previous generation detectors with point LEDs, the GASMAX CX signals alarms by flashing the entire screen, making alarm indications clearly visible to operators and technicians. A menu-driven operator interface eliminates all analog potentiometers and allows setup and calibration without hazardous area declassification. An integrated Run / Calibrate valve and user prompted calibration procedure make routine maintenance and field ‘bump tests’ quick and easy.

Reliability in Hostile Environments

Utilizing a long-life brushless DC pump, the GDS-58NXP Sample Draw is suitable for installation in hazardous areas rated Class I, Div 1, Groups B, C & D.

The GDS-58NXP is ideal for sampling toxic or combustible gases in:

  • Sumps and enclosed areas
  • Cabinets or storeroom with limited ventilation or airflow
  • Air conditioning intake or exhaust plenums and ducts
  • Boiler burners and ducting
FEATURES

  • Single or dual channel - monitor both H2S and LEL simultaneously
  • Supports electrochemical, PID, catalytic bead and infrared sensors
  • High quality diaphragm pump with 24VDC brushless motor
  • Designed for use in Class I, Div 1 Hazardous Locations
  • High visibility color display flashes yellow or red on alarm
  • Setup in hazardous area requires only simple magnetic wand
  • Integrated flow warning switch for ultra-reliable remote operation
  • Built-in flow meter provides visual confirmation of sample flow rate
  • Standard RJ-45 Ethernet interface with built-in web server
  • Prompted calibration procedure and cal port for easy maintenance
  • Sample lines up to 500 ft in length with latency less than 4 minutes
  • Optional 4x alarm relays and dual serial MODBUS interface
  • GASMAX CX auto-configuration with DigitalSensor technology
  • Optional matching 110/220VAC power supply available
  • Manufactured in USA
GDS-IR Features

The GDS-IR Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. The GDS-IR sensor is CSA certified for use in Class 1 Division 1 explosive environ- ments and is CSA performance tested.

Advanced Infrared Technology

The GDS-IR infrared combustible gas sensor offers low total cost of ownership and a seventeen-year MTBF rating. Designed for especially harsh environments, the GDS-IR is virtually maintenance-free and immune to poisoning or etching by any known gas. The sensor element features a self-compensating optical bench, heated optical chamber and fault indication for all failure modes. The optical path can be easily opened for cleaning.

No periodic span calibrations are required. On initial setup and after each cleaning, a simple ‘auto zero’ procedure is used to establish proper operating conditions.

Flexibility

The GDS-IR can be calibrated to read a wide range of combustible hydrocarbons, including methane, propane, hexane, pentane, ethanol, Jet-A, isobutane, propylene and isoproply alcohol, as well as carbon dioxide to 5% by volume. GDS-IR sensors are factory programmed and calibrated when shipped and can be field programmed for alternate response curves. Both LEL and % by volume ranges are available.

GASMAX + GDS-IR Combo

When combined with the GASMAX II monitor, the duo provides local display, 4-20mA output with diagnostics, optional second electrochemical sensor, isolated 4-20mA outputs or MODBUS slave interface with programmable relays.

Reliable Detection

The GDS-IR is manufactured in the USA and includes a five year operational warranty. Applications include refineries, onshore and offshore drilling platforms, fuel loading docks, biogas processing, breweries, wastewater treatment facilities and natural gas storage and distribution.

FEATURES

  • Suitable for use in SIL-2 rated safety systems
  • High speed response for critical applications (T50 less than 3 sec)
  • 5 Year Warranty and long life lowers total cost of ownership
  • 12 Year Warranty on infrared radiation source
  • Rugged stainless steel construction with no moving parts
  • Heated optical chamber maintains accuracy in cold conditions
  • Operates in constant hydrocarbon and anaerobic atmosphers
  • Ten discrete fault indication values for all failure states
  • Straight line optical path eliminates need for mirrors
  • Managed power-up delay reduces initial load on power supply
  • Industry standard 4-20mA current loop calibrated output
  • Multiple gas calibration curves for %LEL and % by volume
  • CSA Certified C22.2 No. 152-M1984 Performance Tested
  • Manufactured in USA

GDS-58DXP SPECIFICATIONS
Power Input: +24VDC nominal
< 10 watts with toxic sensor
< 15 watts with GDS-IR infrared sensor
< 20 watts with dual GDS-IR infrared sensor
Display High resolution graphical LCD transflective (sunlight readable) screen with white LED backlight
User Interface Three magnetic switches for non-intrusive setup and calibration in hazardous areas
Sensor Input Dual channel toxic gas or infrared combustible / CO2 sensors
Alarm Settings Two user-adjustable alarm settings
Draw Distance Demonstrated up to 500 feet using 1/4” OD flexible tubing
Standard Output Dual industry-standard 4-20mA outputs; max 1000 ohm loop load
Optional Relay Output Four alarm / fault relays configurable for alarm set points; latching and non-latching mode; multi-sensor array logic
Digital Output Single isolated two-wire MODBUS serial slave port.
Temp Electronics -40°C to +40°C; Limits may vary depending on sensor Relative humidity 0-99% non-condensing
Housing Aluminum instrument housing, 303 Stainless Steel sensor housing
Dimensions WxHxD 15” x 10.5” x 5” with toxic sensor
WxHxD 15” x 20” x 5” with GDS-IR sensor
Certifications GASMAX DSX CSA: Class I Div 1 Groups B, C, D; T5 Flame arrestors UL and CSA certified for Class I Div 1 areas
Warranty Two-year limited warranty on hardware; one year on sensors.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

20-0141
(3542)

GDS  20-0141

GDS Duct Sample Kit for GDS-58XP, GDS-58NXP and GDS-68XP sample draw gas detectors



 
10-9815-R04
(3355)

GDS  10-9815-R04

Electrochemical Smart Sensor configured for Hydrogen Sulfide (H2S) with range 0-25/0-5000 ppm. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.

1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

SP-5
(4372)

GDS  SP-5

GDS SP-5 solar power system, 5 watts (430mA) of DC power for up to 5 days of low sun conditions, or 3 watts for up to 7 days of low sun conditions. Includes 80Wsolar panel, battery enclosure with pre wired electronic charge controller, 99AH gelled electrolyte battery, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

SP-12
(4374)

GDS  SP-12

GDS SP-12 solar power system, 12 watts (1.0A) of DC power for up to 5 days of low sun conditions, or 5 watts for up to 10 days of low sun conditions. Includes 150W solar panel, battery enclosure with pre wired electronic charge controller, two 84AH gelled electrolyte batteries, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.