Gds Gmii-09-110-06/01-15-04/0-0 | Lel Infrared And Hydrogen Sulfide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GMII-09-110-06/01-15-04/0-0

GDS GMII-09-110-06/01-15-04/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Hexane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others. CSA Certified for Class I, Div 1.

Inquiry

The GASMAX II gas monitor delivers the latest in toxic & combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX II to support any GDS Corp sensor or any combination of one toxic and one combustible (bridge-type) sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX II constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Flexible Output Options

In addition to standard dual 4-20mA current loop outputs, an optional dual isolated 4-20mA output board or an RS-485 two-wire MODBUS® interface with three 5A SPDT relays are available to communicate with controllers or drive local alarm indicators. When used with the C1 Protector controller’s MODBUS master port, multiple GASMAX II monitors can be daisy-chained up to 500m to minimize wiring.

Reliable

Available in both single and dual channel models, the GASMAX II is CSA and ATEX certified for use in Class I, Div 1 explosion proof installations. For low temperature applications, an Arctic Monitor option add thermostatically controlled heaters to enable operation as low as –55°C ambient.

FEATURES

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor both toxic sensors and LEL with one detector
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand

GASMAX II SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input for use with GDS-49 or other standard 4-20mA source.
Standard Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Output #1 Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC.
Optional Output #2 Three Form C Relays 5A @ 30VDC / 240VAC plus RS-485 2-wire MODBUS® slave interface
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP nstallations
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty 2 years from date of purchase on electronics and one year on sensors.
GASMAX II TOXIC GASES
GAS Range
Oxygen (O2) 0-25% Vol.
Carbon Monoxide (CO) 0-100 to 0-9999 ppm
Hydrogen (H2) 0-1000 to 0-5000 ppm
Hydrogen Sulfide (H2S) 0-25 to 0-5000 ppm
Hydrogen Cyanide (HCN) 0-30 ppm
Ethylene Oxide (C2H4O) 0-50 to 0-200 ppm
Arsine (AsH3) 0-1, 0-2 ppm
Silane (SiH4) 0-25, 0-50 ppm
Hydrazine (N2H4) 0-1, 0-2 ppm
Nitric Oxide (NO) 0-50 ppm
Nitrogen Dioxide (NO2) 0-50 to 0-400 ppm
Mercaptan (TBM) 0-15, 0-30 ppm
Tetrahydrothiophene (THT) 0-15, 0-30 ppm
Diborane (B2H6) 0-5 ppm
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    8 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

10-9515-R04
(328)

GDS  10-9515-R04

Electrochemical Smart Sensor configured for Hydrogen Sulfide (H2S) with range 0-25/0-5000 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9550-R06
(262)

GDS  10-9550-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 