Notifier Fst-951 | Intelligent | Thermal | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   FST-951

SKU# (3228)



NOTIFIER FST-951
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360 Degrees viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

RELAYS   UL   FM

FST-951   
Please Email us your request for quote   

Version
Intelligent Bases

   In Stock  ]

The NOTIFIER® FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the FST-851 Series. A new modern, sleek, con- temporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations.

The series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as designated.

FEATURES

SLC LOOP:
  • Two-wire SLC loop connection
  • Unit uses base for wiring
ADDRESSING:
  • Addressable by device
  • Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.)
ARCHITECTURE:
  • Designed to meet UL 268 7th Edition
  • Sleek, low-profile, stylish
OTHER SYSTEM FEATURES:
  • Remote test feature from the panel
  • Walk test with address display
  • Low standby current
OPTIONS:
  • Remote LED output connection to optional RA100Z remote LED annunciator
Installation

FST-951 Series plug-in intelligent thermal detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector.

Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054.

NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet I56-1380 for device limitations between isolator modules and iso- lator bases.

Applications

Use thermal detectors for protection of property. For further informa- tion, refer to I56-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications.

Construction

These detectors are constructed of fire-resistant plastic. The FST- 951 Series plug-in intelligent thermal detectors are designed to com- mercial standards and offer an attractive appearance.

Operation

Each FST-951 Series detector uses one of the panel’s addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FST-951 Series offers fea- tures and performance that represent the latest in thermal detector technology.

Listings and Approvals

Listings and approvals below apply to the FST-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC Listing: S747
  • FM Approved
  • CSFM: 7270-0028:0502

FST-951 SPECIFICATIONS
Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5% to 3.5%
Size: 2.0" (5.3 cm) high; base determines diameter
B300-6: 6.1" (15.6 cm) diameter
B501: 4" (10.2 cm) diameter
For a complete list of detector bases see DN-60981
Shipping Weight: 3.4 oz. (95 g)
Operating Temperature range: FST-951, FST-951R Series: –4°F to 100°F (–20°C to 38°C
FST-951H Series: –4°F to 150°F (–20°C to 66°C)
Detector spacing: UL approved for 50 ft. (15.24 m) center-to-center, FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing
Relative Humidity: 10%-93% non-condensing.
Thermal Ratings: fixed-temperature set point 135 ° F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C)
Mounting: B300-6(A) flanged base, included
ELECTRICAL SPECIFICATIONS
Voltage Range: 15-32 volts DC peak.
Standby Current (max. avg.): 200μA @ 24 VDC (one communication every 5 seconds with LED enabled)
Max current: 4.5 mA @ 24 VDC (“ON”)
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    21 Items found.
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.