Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (3075)

SIERRA MONITOR  5100-08-IT-A1-01-0-0




SIERRA MONITOR 5100-08-IT-A1-01-0-0
  • Overview
  • Features
  • Specs
  • Supplies
  • Literature

Sierra Monitor 5200-08-IT Toxic Gas Leak Detector for Chlorine Dioxide (ClO2) 0-3ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

Part# with Options:        5100-08-IT-A1-01-0-0
Price with Options:        Please Email us your request for quote   

Options:    

Rainshield
(1) Rainshield for Sierra Monitor 5100
Enclosure
(2) Enclosure for Sierra Monitor 5100
Output
(3) Relay/Connection Output for Sierra Monitor 5100
Sensor Protection
(4) Sensor Protection for Sierra Monitor 5100-XX (Toxic)
For very humid, marine and military applications.
Remote Sensor Kit
(5) Remote Sensor Kit for Sierra Monitor 5100

  Availability 3 Weeks  ]

Information Technology (IT) at the component level! A network enabled Gas Sensor Module with the brilliance to provide Sentry, 4-20 mA or Modbus output. This is a stand alone module with the intelligence to provide integral alarms, loaded with features you need. A gas detector with a Sierra Monitor pedigree, Factory Mutual approved and ready to manage your gas risk. The 5100-XX-IT Series provides all the built-in features desired by instrumentation and safety professionals, including:

  • FM Approval for performance and safety
  • 180 day calibration frequency
  • SIL-2 Certified
  • Modbus RTU RS-485 interface
  • 4-20 mA output
  • HART Interface
  • SMC Sentry digital bus interface
  • ATEX Approved (5100-05-IT)
  • IECEx Certified (5100-05-IT)
  • Optional Integral alarm relays – Alarm, Warning and Trouble
  • Aluminum or 316 Stainless Steel enclosure
  • Integral scrolling LED display
  • Remote alarm reset
  • Optional remote sensor

The 5100-XX-IT can be used as a 4-20 mA component or as a Modbus RTU node. For higher level system capabilities the module can interface directly to Sierra Monitor’s Sentry Controller. As part of a Sentry system the user gains capability of system Modbus serial communications, extensive diagnostic features, area and zone alarm management, WebServer interface and multiplexing sensor connections.

Factory Mutual (FM) Approved for electrical safety and environmental parameters including Class I, Div. 1, Groups B, C, D and Class I, Zone 1, Group IIB+H2 IP66. The 5100-XX-IT is also SIL Certified and meets NFPA-72 requirements for gas detectors.

Electrochemical sensors are fuel cell-like devices consisting of an anode, cathode and electrolyte. The components of the cell are selected so a subject gas, allowed to diffuse into the cell, will cause a chemical reaction and generate a current. The cells are diffusion limited so the rate the gas enters the cell is solely dependent on the gas concentration. The current generated is proportional to the rate of the consumption of the subject gas in the cell.

Features

  • Local scrolling display
  • Non-intrusive calibration, menu driven system
  • FM Approved for performance and hazardous area operation, Class I, Div. 1, Group B, C, D, with NEMA 4X enclosure rated for -40 o to 122 o F areas
  • Flexible Modbus, 4-20mA, Sentry bus, HART and relay interface
  • SIL-2 Certified

Benefits

  • Easy to install in a variety of field applications plus easy to obtain critical safety information wherever needed
  • Able to easily and quickly calibrate module without declassifying the area
  • For safe and reliable operation in hazardous areas 5100-05-IT also includes FM Approval for performance
  • Easy to install in a variety of field applications plus easy to obtain critical safety information wherever needed
  • Meets long term reliability design standards

Specifications:
Sensor type: Electrochemical
Performance
Range: Default range as above User selectable alternative ranges)
Sensor Life: Typically >2 years
Output
Display: Fixed and Scrolling LED
Signal Output: Sentry digital bus
Analog 4-20 mA
3-wire Non-Isolated
4-wire Isolated
Serial RS-485 Modbus RTU
Relay: Optional
Options
Relays: 5 amp Alarm, Warning (0.25 amp Trouble)
5A@ 250 VAC, 5A@ 30VDC (Alarm, Warning)
Board includes auxiliary connection for Sentry multiplexing
HART: Termination board includes HART, Modbus RS-485, 4-20mA, Digital Input, 2A Relay output, No Sentry Bus
Power
Power consumption: 2 watts maximum
Input voltage: 24 VDC nominal: 10-30VDC
Construction
Dimensions: (A1 & A2): 7.9 x 5.7 x 3.9 in. (20.1 x 14.5 x 9.9 cm)
(S1 & S2): 7.6 x 4.4 x 4.9 in. (19.3 x 11.2 x 12.4 cm)
Weight: (A1 & A2): 3.4 lb. (1.5 Kg)
(S1 & S2): 7.2 lb. (3.3 Kg)
Housing: Epoxy-coated, die-cast, copper-free Aluminum or 316 Stainless Steel
Rating: Explosion proof, Class 1, Div. I, Groups B, C, D Group IIB + H2 IP66, IP65, NEMA 4X
Warranty: 2 years
Approvals: FM, CSA for enclosure in hazardous locations
FM Performance Approval (5100-05-IT)
SIL-2 Certified (5100-04-IT, 5100-05-IT, 5100-06-IT)
ATEX Certified II 2 G Ex d IIB+H2 T6 Gb
Ta = -20 C to +50 C (5100-05-IT)
IECEx Certified (5100-05-IT)
CE Mark (5100-05-IT)
ABS (5100-05-IT)
CQST Certified for China (5100 -03, -04, & -05 -IT)
CCOE/PESO Certified for India
Gas Specifications:
Gas type Std. Range Opt. Max Range Resolution Response Time Accuracy Operating Range (F)
Oxygen 5-25 %Vol 25 %Vol 0.1% <10 sec. +/- 0.2% - 4 to 122
Carbon Monoxide 0-500 PPM 1200 PPM 0.5 PPM <35 sec. +/- 1 PPM - 4 to 122
Hydrogen Sulfide 0-100 PPM 100 PPM 0.1 PPM <35 sec. +/- 3 PPM - 40 to 122
Chlorine 0-10 PPM 10.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122
Chlorine Dioxide 0-3 PPM 3.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122
Sulfur Dioxide 0-100 PPM 100 PPM 0.5 PPM <20 sec. +/- 0.5 PPM - 4 to 122
Nitrogen Dioxide 0-20 PPM 20 PPM 0.2 PPM <35 sec. +/- 0.5 PPM - 4 to 122
Hydrogen Chloride 0-20 PPM 20 PPM 0.1 PPM <100 sec. +/- 0.1 PPM - 4 to 122
Ammonia 0-100 PPM 100 PPM 1.0 PPM <30 sec. +/- 1 PPM - 14 to 113
Hydrogen Fluoride 0-10 PPM 10 PPM 0.5 PPM <30 sec. +/- 1 PPM - 14 to 113

  • SENSORS (REPLACEMENT) > SIERRA MONITOR
    5200-08-IT Sierra Monitor 5200-06-IT replacement sensor for Chlorine Dioxide (ClO2) 0-3 ppm. Electrochemical Sensor. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal

> CHLORINE DIOXIDE :    15 Items found.
BWS_-V-Y
(6385)

BW  BWS-V-Y

BW Solo Serviceable Single-gas Detector for Chlorine Dioxide (ClO2) 0-1 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$399.50 
M001-0072-000
(5996)

MPOWER  M001-0072-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine Dioxide (ClO2) 0-1ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$403.20 
G02-BA10-100
(3025)

RAE  G02-BA10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Chlorine Dioxide (ClO2) 0-1 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$606.36 
S3KUL2-XNXXSX1SS
(688)

HONEYWELL  S3KUL2-XNXXSX1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE DIOXIDE (CIO2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-1.00ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,324.80 
961-770026-001G
(6354)

DETCON  961-770026-001G

Detcon DM-100-CLO2 Electrochemical Chlorine Dioxide (ClO2) 0-1ppm or 0-50ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ITRANS2-1820000
(6288)

OLDHAM  ITRANS2-1820000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Chlorine Dioxide (ClO2) 0-100% Vol. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

EX-CLO2-2P-O
(6018)

MACURCO  EX-CLO2-2P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Chlorine Dioxide (CLO2) 0-2ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. CSA approvals for Class I Division 2.

Configure

$1,574.12 
GM/EC-03-13-01
(119)

GDS  GM/EC-03-13-01

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (CLO2) with range 0-1 ppm, 4-20 mA output transmitter.

Configure

$1,590.00 
XNXUTAENNNNN-XNXXSX1SS
(838)

HONEYWELL  XNXUTAENNNNN-XNXXSX1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Chlorine Dioxide (ClO2) 0-1.00ppm compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,720.54 
GMII-03-013-01/00-000-00/0-0
(137)

GDS  GMII-03-013-01/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,775.00 
967-747690-050
(6077)

DETCON  967-747690-050

Detcon DM-700-CLO2 Electrochemical "Smart" Chlorine Dioxide (CLO2) 0-50 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

967-777790-001
(6076)

DETCON  967-777790-001

Detcon DM-701-CLO2 Electrochemical "Smart" Chlorine Dioxide (CLO2) 0-1 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

ITR2SA-1820000
(6304)

OLDHAM  ITR2SA-1820000

Oldham iTrans 2 Stand-Alone Gas Detector with electrochemical smart sensor for Chlorine Dioxide (ClO2) 0-100% Vol. 4-20mA. NEMA 4X/IP66 Enclosure to be installed in safe area only (Non-Explosion Proof, no relays nor Modbus/HART available)



 
GMCX-03-13-01/00-00-00/0
(3287)

GDS  GMCX-03-13-01/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (CLO2) with range 0-1 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. For non-clasified areas only

Configure

$2,250.00 
GM/TX/03-13-01/00-00-00/1-0900
(3423)

GDS  GM/TX/03-13-01/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head (non-XP) and integrated sensor configured for Chlorine Dioxide (CLO2) with range 0-1 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,535.00