AMS 3211-700 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Kanthal tube. IP65. Max temp: 1400 °C.

A000352   
Please Email us your request for quote   

Pneumatic Unit
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases
Pneumatic Unit
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases

   4 Weeks  ]


The Application:

The Flue gas probe AMS 3211-700 can be used in applications with high temperatures but low dust loads. The Zircon dioxide sensor of the High temperature Flue gas probe AMS 3211-700 is installed in the flange of the probe. Due to the unique construction of the extraction probe as a Pitot tube, the Flue gas probe AMS 3211-700 supplies the measuring gas to the Zircon dioxide sensor by force of the flue gas flow. A bore hole in the head of the probe provides ambient air as reference air for the sensor. Therefore the High temperature Flue gas probe AMS 3211-700 does not require instrument air during the measurement. The probe design allows the exit of the measuring gas back into the process. In combination with the Transmitter AMS 3220 the High Temperature Flue gas probe AMS 3211-700 is certified for applications according to TA-Luft, 13. and 17. BImSchV and fulfils the requirements for QAL 1 according EN 14181 and EN ISO 14956.

The Measuring principle:

All AMS Flue gas probes are equipped with Zircon dioxide sensors with Platinum electrodes which distinguish themselves by a long lifetime in the process. The Zircon dioxide sensor of the High temperature Flue gas probe AMS 3211-700 is installed in the flange of the probe to reduce the thermal load on the sensor. The measuring gas is supplied to the Zircon dioxide sensor by the flow of the gas through the Pitot tube. Due to the unique design the Flue gas probe AMS 3211-700 can be operated in temperatures up to 1400 °C. To replace the Zircon dioxide sensor of the High temperature Flue gas probe AMS 3211-700 the probe does not have to be dismounted from the duct.

The Measuring system:

The High temperature Flue gas probe AMS 3211-700 can be operated with the Transmitters AMS 3220 or AMS 5200 and a Pneumatic unit. Since the reference air is supplied mechanically by a bore in the head of the probe only one high pressure pneumatic tube is required to supply the calibration gas to the Zircon dioxide sensor. A multi wire, protected cable connects the Transmitter to the Flue gas probe electronically. Due to the modular construction of the Oxygen measuring systems of AMS the Transmitter can be installed inside the housing of the Pneumatic unit. This reduces the required length of both high pressure pneumatic hose and protected cable. The power supply for the Transmitter and the Flue gas probe is also installed in the GRP-housing of the Pneumatic unit. The flue gas probe, the Transmitter and the Pneumatic unit are manufactured according to the protection class IP 65 for General Applications. The Pitot tube of the Flue gas probe is made of temperature resistant Kanthal. Optional the High temperature Flue gas probe AMS 3211-700 can be fitted with Auto-calibration for the automatic time controlled calibration.

AMS 3211-700
Measuring principle ZrO2 sensor with Pt-electrodes
Application Residual oxygen in flue gas
Construction ZrO2 sensor installed in the sensor flange
Gas supply to the sensor by pitot tube with outlet of the sample gas back into the process
Flue gas temp., max. 1400 °C
Dust content (flue gas) max. 2 Gram / Nm3, dry
Flue gas velocity > 0,5 m/s
Time for pre-heating ~ 10 Minutes
T90-Time < 20 Seconds
Reaction time < 5 Seconds
Probe length 300 – 2000 mm
Material Kanthal
Connecting flanges DN 80 PN 16, DN 100 PN 16
Protection IP 65
Reference air supply by diffusion of ambient air to the sensor through a hole in the probe head
Calibration gas supply by separate pneumatic unit
Weight ca. 6,5 kg
Accessories Transmitter: AMS 5200 / AMS 3220 in housing IP 65
Pneumatic unit: GRP housing, Dimensions: 600 x 600 x 200 mm / 800 x 600 x 300 mm. Auto-calibration optional

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
A000154
(2774)

AMS  A000154

AMS 5200 CEMS Analyzer Transmitter for control, monitoring and supply of AMS Flue Gas Probes for O2 (Oxygen) 0-25% Vol. and COe RS232 serial interface. 4-20mA and 0-10V outputs, 2 alarm and 1 status relays. IP65 housing. Optional Pneumatic unit and Ex-d housing for use in Ex-Zone 1 or 2. Compatible Probes: AMS 3211-000 / 500 / 600 / 700 / 860 Ex. Power 110/ 240 VAC, 50/60 Hz or 24 VDC.

> OXYGEN :    4 Items found.
A000249
(2954)

AMS  A000249

AMS 3211-000 ZrO2 installed into flow through cell for installation in EExp Control Cabinet by costumer Electrical connection; Flying Leads without terminal Box

A001694
(2775)

AMS  A001694

AMS 3211-500 Standard In-Line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless steel tube. IP65. Max temp: 550 °C.

A001700
(2776)

AMS  A001700

AMS 3211-600 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Ceramics, Kanthal tube. IP65. Max temp: 1700 °C.

A000636
(2917)

AMS  A000636

AMS 3211-860-150 In-line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless Steel tube. IP65. Max temp: 500 °C. Ex Zone1 or Ex Zone 2.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.