Intec Spc3-1120-200us | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTEC   SPC3-1120-200US

INTEC SPC3-1120-200US
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Intec Controls PolyGard SPC3-1120 Sigle-Point Gas Detector for Ammonia (NH3) 0-300 / 0-1000 ppm, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. *** phased out replaced by SGC6 ***

Inquiry

APPLICATION

To detect and control levels of ammonia (NH3) and other gases in a wide variety of commercial and industrial applications such as the ammonia level in chiller equipment rooms, food storages, freezers, arenas, breweries, and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC/PLC control or automation system via binary and/or analog output signal.

FEATURES
  • Continuous monitoring
  • One (1) built-in NH3 electrochemical sensor
  • Easy plug-in sensor
  • One (1) remote analog input, 4-20 mA
  • One (1) digital input
  • Two (2) relay outputs:
    Four stage control
    Fail-safe assignable
  • One (1) analog output, (0)4-20 mA / (0)2-10 VDC - Selectable for low, high, or averaging
  • One (1) 24 VDC switched output
  • Liquid Crystal Display (LCD)
  • LED status indicators
  • Accepts toxic or combustible gas, refrigerant, temperature or humidity secondary remote sensor input
  • Built-in horn
  • Keypad user interface
  • Simple menu-driven programming
  • Modular technology
  • Overload & short-circuit protected
  • NEMA 4X enclosure
  • Easy maintenance

Specifications
Electric
Power supply 24 VAC/VDC, -20%/+15% 50/60 Hz, reverse polarity protected
Power consumption 5 VA (0.2 A) w/ (1) remote sensor connected
Sensor Performance
Gas detected Ammonia (NH3)
Sensor element Electrochemical, diffusion
Range 0-300 ppm or 0-1000 ppm, fixed “refer to Ordering Information”
Resolution 4.0 ppm
Repeatability ± 3.0 % of reading
Long term output drift < 5% / 6 months
Response time t90 < 35 sec.
Sensor life expectancy 2 years, normal operating environment
Sensor coverage 2,000 sq. ft., max 3,000 sq. ft. (180 m2, max 280 m2), under “ideal conditions”
Installation Location
Mounting height 1 ft. (0.3 m) below ceiling
Type of Control
General Four-stage (S1 to S4) control, assignable up to two (2) binary/ relay, horn/audible alarm, and 24 VDC / 50 mA switched outputs, i.e. low-high stage for relay output, horn / audible alarm and switched 24 VDC at any stage for remote alarming
Analog input One (1) 4-20 mA, for additional remote sensor, load < 55 mA / 200 Ω, reverse polarity protected
Analog reading Current and mean (average) value
Stage level / setpoint Field adjustable over full range, four (4) stages (S1 to S4) per analog input, assignable to current or mean (average) value
- hysteresis/ switching differential Selectable for each sensor point
Digital input One (1); can be assigned to any relay (R1, R2)
- application Remote audio/visual alarm reset or override function
Type of Control (cont...)
Relay outputs (R1, R2) w/ status LEDs (1) SPDT (R1), and (1) SPST-NC or SPST-NO (R2), jumper selectable
Contact rating
-each stage level (S1-S4)
-sensor fail-safe
30 VAC/VDC, 0.5 A, max.
Assignable to any relay
Assignable to any stage level
Time delay switching Selectable for make and brake of each sensor point (SP1 to SP2) 0‐9,999 seconds
Analog output One (1), (0)4‐20 mA, load < 500 Ω;(0)2-10 VDC, load > 50K Ω; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs
VDC switched output One (1) 24 VDC, 50 mA max
Audible alarm 83 db @ unit, enabled or disabled, selectable; assignable to stage level S1, S2, S3 or S4
Alarm acknowledgment Menu-driven and system reset function for latched relays
User Interface
Keypad type Refer to illustration “Keypad User Interface”
Touch buttons Four (4)
Status LED’s Four (4), for system on, stage status, and failure
Digital display Liquid Crystal Display (LCD), two lines, 16 characters per line, 1 digit resolution
-unit display Menu selectable, per sensor; ppm, %v/v, %LEL, °F or %RH
Environmental
Permissible ambient
-working temperature 14°F to 122°F (-10°C to 50°C)
-storage temperature 23°F to 86°F (-5°C to 30°C)
-humidity 15 to 95% RH, non-condensing
-working pressure Atmospheric ± 10%
Physical
Enclosure (panel)
-material Polycarbonate, UL 94-HB, fire-retardant
-conformity UL 50 standards
-color Light gray
-protection NEMA 4X (IP65)
-installation Wall (surface) mounted, or single gang electrical box
Dimensions (H x W x D) 5.12 x 5.12 x 2.95 in.
Wire connection Terminal blocks, screw type for lead wire
Wire size Min. 24 AWG (0.25 mm 2 )
Max 14 AWG (2.5 mm 2 )
Wire distance Max. loop resistance 450 Ω (= wire distance plus controller input resistance)
Weight 0.6 lb. (0.3 kg)
Approvals / Listings
-unit rating NRTL Certification to STD
ANSI/UL 61010-1
CE
EMV-Compliance 2004/108/EWG
Low voltage directive 73/23/EWG
-relays (R1-R2) UL Recognized, E41515
CSA, C22.2 No. 0, No. 14 (File No. LR31928)
-enclosure UL Listed, E208470
CSA Certified, E208470
Warranty Two years material and workmanship, 12 months normal exposure for sensor element
> AMMONIA :    43 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$690.96 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
51001AL-0-1015/0300P/L0
(7123)

RC SYSTEMS  51001AL-0-1015/0300P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
GG-NH3-2-EXP
(4149)

CALIBRATION TECHNOLOGIES  GG-NH3-2-EXP

CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.

Configure

$1,842.00 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
GDS-IR2-1-301-0
(5829)

GDS  GDS-IR2-1-301-0

GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.