Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (1854)

GDS  GMIIx-00-000-00/01-050-06/1-0900

$2,436.89     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount
      



GDS GMIIx-00-000-00/01-050-06/1-0900
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Documents

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Toluene, Acetone, MEK and Xylene.

Part# with Options:        GMIIx-00-000-00/01-050-06/1-0900
Price with Options:        2,436.89

Options:    

Configuration
(1) Configuration for GDS GASMAX TX
Sensor Head (Channel 2)
(2) Sensor Head for GDS GMIIx CH2
Sensor Type (Bridge/mA channel)
(3) Sensor Type for GDS GMII (SmartIR)
Enclosure
(4) Stainless Steel Enclosure for GDS
Tag
(5) Tag for GDS
Antenna
(6) Antenna Style for Gasmax wireless

  Availability 2 Weeks  ]

The GASMAX IIx gas monitor delivers the latest in wireless toxic or combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Advanced electronics allows the GASMAX IIx to support any single GDS Corp electrochemical toxic or bridge-type catalytic bead, infrared or PID sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX IIx constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Fully Integrated Wireless Solution

An internal 900Mhz or 2.4Ghz license- free spread-spectrum wireless modem allows the GASMAX IIx to transmit gas detection data to a remote host controller. Every 6 seconds, the GASMAX IIx samples the atmosphere and transmits a warning signal if the pre-programmed alarm level is exceeded. Under normal “no-gas” conditions the GASMAX IIx transmits a ‘keep-alive’ signal every five minutes to verify communications.

Host Controllers

The GASMAX IIx is designed to communicate with the C1 Protector 8/16 channel controller / receiver or the C2 Quad Protector 4 channel controller / receiver. Both controllers are available with integrated 900Mhz or 2.4Ghz wireless modems.

FEATURES

  • Integrated radio modem enables wireless data transmission
  • Monitor toxic or combustible gases in remote locations without wires
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • 900Mhz (US) or 2.4Ghz (worldwide) versions available
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Typical > 1 mile range with local ‘whip’ antenna (900Mhz)
  • For battery applications, see the GASMAX/ECx gas monitor
  • Manufactured in USA
Determining Wireless Communications Range

The distance at which any wireless connection will operate reliably is dependent on many factors, including terrain, frequency, path length, interference from existing radio sources, combined antenna height, transmitter power and receiver sensitivity. For reliable communication, the system power margin (TX power + RX gain + Antenna gain - Path Loss) must exceed 20 dB. Range can be improved by increasing antenna height, using directional antennas or increasing transmitter power.

GASMAX IIx SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with wireless radio modem.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input.
Standard Output License-free 900Mhz or 2.4Ghz frequency-hopping spread spectrum wireless modem with data encryption
900MHz power adjustable from 10mW to 1.0 watt 900MHz;
2.4GHz output fixed at 50mW
Receiver sensitivity typically -110dBm
Temp -25°C to +65°C (see sensor limitations)
Housing AAluminum with epoxy paint standard; #316 stainless optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals Suitable for XP installations
Warranty 2 years on electronics and one year on sensors.

Gases

GAS TYPE SENSOR RANGE COMMENTS
Methane 0 – 5% volume Fully characterised for methane.
Methane 0 – 100% volume Fully characterised for methane
Propane 0 – 2% volume Fully characterised for propane.
Cross-reference factors available for: Butane, Pentane,
Hexane, Ethanol, Ethylene, Propylene, Ethane, Cyclopentane,
Isopropanol, Methanol, Toluene, Acetone, Methyl ethyl ketone
(MEK) and Xylene , see Note 1
Propane 0 – 100% volume Fully characterised for propane
Propylene 0 – 100% volume Fully characterised for propylene
Butane 0 – 2% volume Fully characterised for butane
Pentane 0 – 2% volume Fully characterised for pentane
Hexane 0 – 1% volume Sensor output linearised for hexane, see Note 1
Ethylene 0 – 3% volume Sensor output linearised for ethylene, see Note 1
Ethane 0 – 3% volume Fully characterised for ethane
Ethylen Oxide 0 – 3% volume Fully characterised for ethylene oxide
Ethanol 0 – 5% volume Sensor output linearised for ethanol, see Note 1
Methyl Bromide 0 – 25,000 ppm Sensor output linearised for methyl bromide, see Note 1

  • SENSORS (REPLACEMENT) > GDS SMART INFRARED
    10-9550-R06 Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor h ..
  • SENSORS (REPLACEMENT) > GDS SMART INFRARED
    10-9551-R06 Infrared Smart IR LEL Sensor with range 0-100% LEL (Lower Explosive Limit) for combustibles (specify). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and ..
  • SENSORS (REPLACEMENT) > GDS SMART INFRARED
    10-9552-R06 Infrared Smart IR LEL Sensor configured for Methane by Volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS- ..
  • SENSORS (REPLACEMENT) > GDS SMART INFRARED
    10-9553-R02 Infrared Smart IR Sensor configured for Carbon Dioxide CO2 with range 0-5% volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASM ..
  • SENSORS (REPLACEMENT) > GDS SMART INFRARED
    10-9557-R02 Infrared Smart IR Sensor configured for Ethylene Oxide ETO with range 0-3% volume. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASM ..

  • CALIBRATION GAS GDS > METHANE
    1200-0267 GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder. ..

  • CALIBRATION GAS GDS > METHANE
    1200-0768 GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > METHANE
    1200-0522 GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • CALIBRATION KITS GDS > METHANE
    1200-0587 GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS (WIRELESS) > LEL INFRARED :    24 Items found.
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,074.22 
GDS-48-1-50-06
(344)

GDS  GDS-48-1-50-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with SmartIR sensor for combustibles and Methane (CH4) 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.

Configure

$1,090.00 
GDS-50-1-50-06
(1643)

GDS  GDS-50-1-50-06

GDS GDS-50 Remote Infrared IR Sensor Transmiter for Combustible (LEL) 0-100% Vol with replaceable sensor and 4-20 mA Output. Designed for Class 1 Division 1. -20°C to +50°C. Available gases: Methane (CH4), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Ethylene Oxide (ETO), Ethane (C2H6), Hexane (C6H14), Propene (C3H6), Ethylene (C2H4), Acetone (C3H6O) and Ethanol (C2H6O)

Configure

$1,090.00 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX IECEx available.

Configure

$1,156.30 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor

TMII-00-00-00/48-50-06/0-0
(1669)

GDS  TMII-00-00-00/48-50-06/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head with integrated sensor configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$1,510.00 
XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,601.99 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,601.99 
2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$1,638.53 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$1,638.53 
GMII-00-000-00/01-050-06/0-0
(185)

GDS  GMII-00-000-00/01-050-06/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Ethanol, Toluene, Acetone, MEK and Xylene.

Configure

$1,840.00 
GDS-IR-1-110-1
(436)

GDS  GDS-IR-1-110-1

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP). Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

Configure

$1,890.00 
2108N5100N
(1965)

HONEYWELL  2108N5100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485. Hydrocarbon calibration (Methane (Natural Gas), Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit), for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output.

Configure

$1,913.65 
100-0001-M11-SS
(4722)

ESP SAFETY  100-0001-M11-SS

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases (Methane, Propane, Butane, Pentane, Hexane, Cyclopentane or Ethanol). Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,920.00 
5100-28-IT-A1-01-01-0-0-F
(3081)

SIERRA MONITOR  5100-28-IT-A1-01-01-0-0-F

Sierra Monitor 5200-28-IT Infrared Gas Leak Detector for Combustibles 0-100% LEL (methane and others). ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups C, D.

Configure

$2,095.33 
2108N5110N
(1966)

HONEYWELL  2108N5110N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for gas ranges 0–100 %v/v Methane (CH4), 0–600,000 ppm Propane (C3H8) and 0–400,000 ppm Propane (C3H8). 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485. Hydrocarbon calibration fitted with remote gassing cell and flow housing.

Configure

$2,212.06 
C2-48-050-06/00-000-00/0-0-0-0-0/0-0
(379)

GDS  C2-48-050-06/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with SmartIR Methane (Natural Gas) integrated sensor with range combustible 0-100% LEL (Lower Explosive Limit) with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Ethanol, Toluene, Acetone, MEK and Xylene.

Configure

$2,245.00 
GMCX-01-50-06/00-00-00/0
(3309)

GDS  GMCX-01-50-06/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit), QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Toluene, Acetone, MEK and Xylene.

Configure

$2,270.00 
RMII-00-00-00/02-50-06/1-0-1-0
(5162)

GDS  RMII-00-00-00/02-50-06/1-0-1-0

GDS RigMAX Single Channel Gas Monitor with Integrated strobe and 99dB horn with Infrared sensor for Methane with range 0-100% LEL (Lower Explosive Limit). Includes backlit display and 100 ft #18GA neoprene power cable. 24 VDC. Aluminium Housing and 4 point magnetic mount. CSA Certified for Class 1, Div 1, Groups B, C & D. Available calibrated to Methane (Natural Gas), Propane (LP) and other hydrocarbons.

Configure

$2,430.00 
GD10-P00-17DG-00H
(1868)

SIMTRONICS  GD10-P00-17DG-00H

Simrad GD10P IR Point Gas Detector for combustible gases: Methane (CH4) , Ethylene (C2H4), Propane (C3H8), Acetylene, Butane and others on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

Page: 1 | 2 | All