Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (1834)

GDS  GMIIx-03-013-01/00-000-00/1-0900

$2,228.01     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GMIIx-03-013-01/00-000-00/1-0900
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Chlorine Dioxide (CIO2) with range 0-1 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Part# with Options:        GMIIx-03-013-01/00-000-00/1-0900
Price with Options:        2,228.01

Options:    

Configuration
(1) Configuration for GDS GASMAX TX
Sensor Head (Channel 1)
(2) Sensor Head for GDS GMIIx CH1 (reactive gases non-XP)
Enclosure
(3) Stainless Steel Enclosure for GDS
Tag
(4) Tag for GDS
Antenna
(5) Antenna Style for Gasmax wireless

  Availability 2 Weeks  ]

The GASMAX IIx gas monitor delivers the latest in wireless toxic or combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Advanced electronics allows the GASMAX IIx to support any single GDS Corp electrochemical toxic or bridge-type catalytic bead, infrared or PID sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX IIx constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Fully Integrated Wireless Solution

An internal 900Mhz or 2.4Ghz license- free spread-spectrum wireless modem allows the GASMAX IIx to transmit gas detection data to a remote host controller. Every 6 seconds, the GASMAX IIx samples the atmosphere and transmits a warning signal if the pre-programmed alarm level is exceeded. Under normal “no-gas” conditions the GASMAX IIx transmits a ‘keep-alive’ signal every five minutes to verify communications.

Host Controllers

The GASMAX IIx is designed to communicate with the C1 Protector 8/16 channel controller / receiver or the C2 Quad Protector 4 channel controller / receiver. Both controllers are available with integrated 900Mhz or 2.4Ghz wireless modems.

FEATURES

  • Integrated radio modem enables wireless data transmission
  • Monitor toxic or combustible gases in remote locations without wires
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • 900Mhz (US) or 2.4Ghz (worldwide) versions available
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Typical > 1 mile range with local ‘whip’ antenna (900Mhz)
  • For battery applications, see the GASMAX/ECx gas monitor
  • Manufactured in USA
Determining Wireless Communications Range

The distance at which any wireless connection will operate reliably is dependent on many factors, including terrain, frequency, path length, interference from existing radio sources, combined antenna height, transmitter power and receiver sensitivity. For reliable communication, the system power margin (TX power + RX gain + Antenna gain - Path Loss) must exceed 20 dB. Range can be improved by increasing antenna height, using directional antennas or increasing transmitter power.

GASMAX IIx SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with wireless radio modem.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input.
Standard Output License-free 900Mhz or 2.4Ghz frequency-hopping spread spectrum wireless modem with data encryption
900MHz power adjustable from 10mW to 1.0 watt 900MHz;
2.4GHz output fixed at 50mW
Receiver sensitivity typically -110dBm
Temp -25°C to +65°C (see sensor limitations)
Housing AAluminum with epoxy paint standard; #316 stainless optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals Suitable for XP installations
Warranty 2 years on electronics and one year on sensors.

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9513-R01 Electrochemical Smart Sensor configured for Chlorine Dioxide (ClO2) with range 0-1 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> CHLORINE DIOXIDE :    21 Items found.
M001-0072-000
(5996)

MPOWER  M001-0072-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine Dioxide (ClO2) 0-1ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
BWS_-V-Y
(6385)

BW  BWS-V-Y

Honeywell BW Solo Serviceable Single-gas Detector for Chlorine Dioxide (ClO2) 0-1 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$413.60 
0401114
(6499)

DEGA  0401114

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Chlorine dioxide (CLO2) with range 0-1ppm. 4-20mA 3-Wire and RS-485 outputs. IP54.



$420.33 
0402083
(6520)

DEGA  0402083

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Chlorine Dioxide (ClO2) with range 0-1ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54. ATEX Zone 2.

Configure

$439.88 
0407218
(6545)

DEGA  0407218

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Chlorine Dioxide (ClO2) with range 0-1ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54. ATEX Zone 2.

Configure

$498.53 
GAXT-V-DL
(490)

BW  GAXT-V-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Chlorine dioxide (ClO2) 0-1.0 ppm.

Configure

$551.76 
G02-BA10-100
(3025)

RAE  G02-BA10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Chlorine Dioxide (ClO2) 0-1 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$663.10 
S3KUL2-XNXXSX1SS
(688)

HONEYWELL  S3KUL2-XNXXSX1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE DIOXIDE (CIO2) with electrochemical sensor, 2-wire 4-20mA loop, 0-1.00ppm

Configure

$1,285.72 
ITRANS2-1820000
(6288)

OLDHAM  ITRANS2-1820000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Chlorine Dioxide (ClO2) 0-100% Vol. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

961-770026-001G
(6354)

DETCON  961-770026-001G

Detcon DM-100-CLO2 Electrochemical Chlorine Dioxide (ClO2) 0-1ppm or 0-50ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GM/EC-03-13-01
(119)

GDS  GM/EC-03-13-01

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (CLO2) with range 0-1 ppm, 4-20 mA output transmitter.

Configure

$1,475.00 
EX-CLO2-2P-O
(6018)

MACURCO  EX-CLO2-2P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Chlorine Dioxide (CLO2) 0-2ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,613.47 
5100-08-IT-A1-01-0-0
(3075)

SIERRA MONITOR  5100-08-IT-A1-01-0-0

Sierra Monitor 5200-08-IT Toxic Gas Leak Detector for Chlorine Dioxide (ClO2) 0-3ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

XNXUTAENNNNN-XNXXSX1SS
(838)

HONEYWELL  XNXUTAENNNNN-XNXXSX1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Chlorine Dioxide (ClO2) 0-1.00ppm compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,617.14 
GMII-03-013-01/00-000-00/0-0
(137)

GDS  GMII-03-013-01/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,645.00 
967-777790-001
(6076)

DETCON  967-777790-001

Detcon DM-701-CLO2 Electrochemical "Smart" Chlorine Dioxide (CLO2) 0-1 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

967-747690-050
(6077)

DETCON  967-747690-050

Detcon DM-700-CLO2 Electrochemical "Smart" Chlorine Dioxide (CLO2) 0-50 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

GM/ECx-03-13-01-1-0900
(1811)

GDS  GM/ECx-03-13-01-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Chlorine Dioxide (CIO2) with range 0-1 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$2,025.00 
ITR2SA-1820000
(6304)

OLDHAM  ITR2SA-1820000

Oldham iTrans 2 Stand-Alone Gas Detector with electrochemical smart sensor for Chlorine Dioxide (ClO2) 0-100% Vol. 4-20mA. NEMA 4X/IP66 Enclosure to be installed in safe area only (Non-Explosion Proof, no relays nor Modbus/HART available)



 
GMCX-03-13-01/00-00-00/0
(3287)

GDS  GMCX-03-13-01/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (CLO2) with range 0-1 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. For non-clasified areas only

Configure

$2,140.00 
Page: 1 | 2 | All