Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (1814)

GDS  GM/ECx-03-16-12-1-0900

$1,925.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GM/ECx-03-16-12-1-0900
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Part# with Options:        GM/ECx-03-16-12-1-0900
Price with Options:        1,925.00

Options:    

Configuration
(1) Configuration for GDS GM/ECx
Sensor Head
(2) Sensor Head for GDS GM/ECx (reactive gases, IS)
Enclosure
(3) Stainless Steel Enclosure for GDS
Tag
(4) Tag for GDS
Antenna
(5) Antenna Style for Gasmax wireless

  Availability 2 Weeks  ]

The GASMAX ECx wireless gas monitor delivers the latest in toxic gas detection technology, reliability and ease of use. The GASMAX / ECx is designed for use in hazardous or explosion proof installations.

Wide Variety of Available Sensors

The GASMAX ECx support all GDS Corp toxic sensors; in addition, GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more.

Using this information, the GASMAX ECx constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible display and alarm LEDs constantly show status, calibrated engineering values and a programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu- driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Fully Integrated Wireless Solution

An internal D-cell lithium battery and 900Mhz or 2.4Ghz license-free spread- spectrum wireless modem provide up to six months of continuous operation in typical applications. Every 6 seconds, the GASMAX ECx samples the atmosphere and transmits a warning signal if the pre-programmed alarm level is exceeded. Under normal conditions the GASMAX ECx transmits a ‘keep-alive’ signal periodically to verify communications and advise the controller if the battery is low. Host Controllers

The GASMAX ECx is designed to operate with the C1 Protector 8/16 channel controller / receiver, the C2 Quad Protector 4 channel controller / receiver or the C64 Protector multi-channel controller. Controllers are available with integrated 900Mhz or 2.4Ghz wireless modems.

FEATURES

  • Built-in D-cell lithium battery and integrated wireless modem
  • Monitor for toxic gases in remote locations without wires
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • 900Mhz (US) or 2.4Ghz (worldwide) wireless modems available
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Typical > 1 mile range with local ‘whip’ antenna (900Mhz)
  • For combustible applications, see the GASMAX IIx gas monitor
  • Manufactured in USA
Determining Wireless Communications Range

The distance at which any wireless connection will operate reliably is dependent on many factors, including terrain, frequency, path length, interference from existing radio sources, combined antenna height, transmitter power and receiver sensitivity. For reliable communication, the system power margin (TX power + RX gain + Antenna gain - Path Loss) must exceed 20 dB. Range can be improved by increasing antenna height, using directional antennas or increasing transmitter power. Contact GDS Corp for more information.

GASMAX ECx SPECIFICATIONS
Power Input: Replaceable internal D-cell lithium battery; six-month operation (typical)
Display 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Input Accepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Standard Output License-free 900Mhz or 2.4Ghz frequency-hopping spread spectrum wireless modem with data encryption
900MHz power adjustable from 10mW to 1.0 watt
2.4GHz output set at 50mW or 125mW (US only)
Receiver sensitivity typically -98dBm
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals FCC 15.247 & Industry Canada (IC)
Warranty Two years on electronics and one year on sensors from date of purchase

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9516-R12 Electrochemical Smart Sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, ..

  • CALIBRATION GAS GDS > HYDROGEN CYANIDE
    1200-0285 GDS Gas Detector Calibration Gas Cylinder Hydrogen Cyanide (HCN) 10ppm. Balance Air. 58L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > HYDROGEN CYANIDE
    1200-0513 GDS Gas Detector Calibration Gas Kit Hydrogen Cyanide (HCN) 10ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS (WIRELESS) > HYDROGEN CYANIDE :    18 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
BWS_-Z-Y
(6388)

BW  BWS-Z-Y

Honeywell BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$413.60 
GAXT-Z-DL
(482)

BW  GAXT-Z-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Hydrogen cyanide (HCN) 0-30 ppm.

Configure

$551.76 
G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
10076729
(1660)

MSA  10076729

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm



$577.98 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$897.60 
961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ITRANS2-1940000
(6289)

OLDHAM  ITRANS2-1940000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

GM/EC-01-16-12
(127)

GDS  GM/EC-01-16-12

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head explosion proof (XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, 0-30ppm

Configure

$1,396.01 
EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,432.09 
GMII-01-016-12/00-000-00/0-0
(140)

GDS  GMII-01-016-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,727.54 
GMCX-01-16-12/00-00-00/0
(3290)

GDS  GMCX-01-16-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-03-016-12/00-000-00/1-0900
(1837)

GDS  GMIIx-03-016-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
ITR2SA-1940000
(6305)

OLDHAM  ITR2SA-1940000

Oldham iTrans 2 Stand-Alone Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA. NEMA 4X/IP66 Enclosure to be installed in safe area only (Non-Explosion Proof, no relays nor Modbus/HART available)



 
GM/TX/01-16-12/00-00-00/1-0900
(3426)

GDS  GM/TX/01-16-12/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00