Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (1660)

MSA  10076729

$568.60     Availability: 7 Days
 Info/Quote Request
 Shipping Rates
 Volume discount
MSA 10076729
  • Overview
  • Benefits
  • Specs
  • Literature

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm

$568.60      

  Availability 7 Days  ]

These innovative toxic gas and oxygen detectors are based upon the design of the popular ALTAIR Single-Gas Detector, but with added features and functionality.

FEATURES

  • Tough rubberized housing
  • One-button operation
  • Accurately measures gas
  • Great RFI performance concentration or percent oxygen
  • Displays information on a large, clear, backlit LCD. are offered for LOW, HIGH, TWA, and STEL
  • Adjustable alarm set points
  • Superior dust and water protection (rated IP67 except O2-R)
  • Event-logging and data-logging
  • Alarms are indicated by flashing LEDs, audible alarm, and internal vibrating alarm
  • Excellent impact resistance
  • Replaceable battery and sensor

The ALTAIR Pro Single-Gas Detector provides worry-free performance and stands up to the roughest handling in even the toughest industrial environments. Sensors and battery are easily replaced to keep the unit performing for years.

The ALTAIR Pro Single-Gas Detector is designed and built with MSA’s superior quality and is part of MSA's ALTAIR Detector family of products.

Ease-of-Use

The ALTAIR Pro Single-Gas Detector combines user flexibility and functional simplicity. True single-button operation provides users with a clear path to any function. With a single button, users can:

  • turn the unit on.
  • activate the backlight.
  • activate the infrared link for communication with a computer.
  • display information about the unit, such as software version and alarm settings.
  • perform a fresh air setup (FAS).
  • initiate a bump test.
  • change calibration gas concentration.
  • initiate calibration.
  • reset peak reading display.
  • manually change LOW, HIGH, TWA, STEL alarm set points (in protected SETUP (mode only).
  • turn the unit off.
Another ease-of-use feature is the built-in gas delivery adapter; no accessories are needed to conduct gas response tests, eliminating hidden replacement costs.

Distinctive Alarm System

Triple alarm system leaves no doubt for users in alarm situations. Piercing audio alarm averages 95 dB @ 1 foot and is designed to be distinctive from other workplace sounds. Extended frequency range covers a wide sound spectrum. Visual alarm features dual LED displays located on the unit’s top, visible from all angles. Internal vibrating alarm is also standard on all units, emitting a pulse that directly calls additional attention to users when in alarm mode.

Easily Replaceable, Commercially Available Battery

The detector runs on a single CR2 camera battery, simple to install and commercially available. Installed battery life is approximately 9,000 hrs (> 1 year). A long wake-up period each time units are activated is avoided by supplying small amounts of power to sensors even when units are powered off.

Remote Oxygen Detector (O2-R)

The remote oxygen version for The ALTAIR Pro Single-Gas Detector’s remote oxygen sensor attaches remotely to the end of a ten-foot cable, rather than inside instrument housing. Design allows users to lower the sensor into remote locations and monitor O2 levels from ten feet away.

Sensors

The ALTAIR Pro Single-Gas Detector uses fast-responding 20 Series oxygen and toxic sensors and meets UL, cUL, ATEX, and Australian standards. Sensors simply plug in to the internal circuit board for fast, easy replacement.

Built-In IR Communication (Event & data logging)

Data logging is standard on the Altair Pro Single-Gas Detector. The unit automatically records the 50 latest events in the session log, while simultaneously recording peak gas readings or low O2 readings every three minutes in a periodic data log. Combined, these two tools provide a great way to assess alarm conditions, confirm bump tests or calibration, and verify employee gas concentration exposures.

To access data, simply link the unit to your MSA infrared adapter using standard built-in IR communication. MSA FiveStar® LinkTM Software allows you to view various logs, adjust alarm set points, assign the unit a specific name, and disable or activate particular features and options, a one-stop unit control center.

Rugged Design

Thick rubberized housing withstands accidental drops or other impacts and also provides additional water ingress resistance. Metal screw inserts offer stability over the unit’s lifetime. A durable suspension clip completes this tough outer shell.

Water and Dust Resistance

The ALTAIR Pro Single-Gas Detector is highly water-and dust-resistant. Simple yet effective design innovatively seals the unit, exceeding the industry average IP rating.

Test and Calibration Stations

MSA is proud to offer the ALTAIR QuickCheck® Station, an easy and cost- effective way to perform daily alarm and gas response tests on your ALTAIR Pro Single-Gas Detectors. The station is available in manual and automatic versions and quickly verifies that the instrument is ready for the upcoming day’s use.

MSA also offers the ALTAIR Galaxy® Automated Test System for complete automatic calibration and record-keeping of your ALTAIR Pro Single-Gas Detectors. Please contact MSA for additional information on either of these stations.

Specifications
Weight 4.0 oz including clip
Dimensions 3.4” x 2.0” x 1.0”
Operating T Range -20oC to +50oC
Humidity 10-95% RH non-condensing
Alarms Average > 95 dB @ 1 ft, bright LEDs, vibrating alarm standard
Warranty See instruction manual for full warranty information
Instrument Life Indefinite with sensor and battery replacement as needed
Battery CR2 lithium camera battery (9000 hour installed life - typical)
Case Polycarbonate with rubberized shell
Display Large LCD with backlight
Ingress Protection IP67 (except O2-R is IP54)
Data Logging 50 latest events in session log Peak value every 3 minutes in periodic log
Certifications
US and Canada
Europe
USA
European Union
Australia

Class I, Div. 1, Groups A, B, C and D;Class II, Div. 1, Group G
Ex ia IIC T4
AEx ia IIC T4
ATEX II 2G Ex ia IIC T4
Ex ia IIC T4 (Ta = 50 ̊C)


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HYDROGEN CYANIDE :    21 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
BWS_-Z-Y
(6388)

BW  BWS-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$399.50 
G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
20100043
(6487)

DEGA  20100043

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Hydrogen cyanide (HCN) with range 0-50ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$645.12 
30100037
(6519)

DEGA  30100037

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-50ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$783.36 
20100137
(6675)

DEGA  20100137

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Hydrogen cyanide (HCN) with range 0-50ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$897.60 
30100126
(6549)

DEGA  30100126

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-100ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$967.68 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GM/EC-01-16-12
(127)

GDS  GM/EC-01-16-12

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
ITRANS2-1940000
(6289)

OLDHAM  ITRANS2-1940000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,432.09 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, 0-30ppm

Configure

$1,438.30 
GMII-01-016-12/00-000-00/0-0
(140)

GDS  GMII-01-016-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,766.40 
GM/ECx-03-16-12-1-0900
(1814)

GDS  GM/ECx-03-16-12-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-16-12/00-00-00/0
(3290)

GDS  GMCX-01-16-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-03-016-12/00-000-00/1-0900
(1837)

GDS  GMIIx-03-016-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-16-12/00-00-00/1-0900
(3426)

GDS  GM/TX/01-16-12/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00 
Page: 1 | 2 | All