Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (1640)

HONEYWELL  2106B2310

$601.64     Availability: 4 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



HONEYWELL 2106B2310
  • Overview
  • Features
  • Specs
  • Related
  • Literature

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Part# with Options:        2106B2310
Price with Options:        601.64

Options:    

Entry Size
(1) Entry Size for Honeywell Sieger Sensepoint (H. Temp)
Weather housing
(2) Honeywell Sensepoint (Combustibles)
Terminal Housing
(3) Honeywell Sensepoint Terminal Housing/Junction Box
Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved

  Availability 4 Weeks  ]

The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics’ controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/ IECEx safety and performance standards.

The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.

The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of ‘sticky’ gases such as Chlorine and Ammonia.

Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Fit For Purpose
  • Flammable, toxic and Oxygen versions available
  • High performance, low cost
  • Suitable for new and retro fit applications
Proven Sensor Technology
  • SurecellTM electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life
ATEX/IECEx Certified
  • Complies with the latest standards
  • Hazardous area approval and performance
  • IP65/67 for use in harsh environments
  • Easy to Use
  • Factory set operation
  • Simple to replace
  • Minimal training required
Range of Accessories
  • Weatherproof cap
  • Flow adaptor
  • Duct mounting kit
  • Collecting cone

Installation Details

Dimensions

Sensepoint Dimensions

Sensepoint flammable and toxic gas detectors are installed using suitable Ex d or Ex e junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences.

The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Electrical Connections

Sensepoint Electrical Connections

Flammable
0-100% LEL
Operating Temp -40 to +80˚C
Operating HumidityContinuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing)
Storage Conditions0 to 25˚C; 30 to 70% RH
Operating Pressure90 to 110kPa
Warm-up Time < 10 minutes
Response Time
T20  
T50 < 5 secs
T90 < 10 secs
Supply200mA; 0.7W maximum
Signal OutputmV bridge
Linearity< 5% fsd or ±10% of reading
Operating Life5 years (typical)
Storage Life Typically, over 5 years when in original sealed packaging
Stability (zero)
with time* < ±3% fsd / yr
with temperature** < ±1% fsd
with humidity < ±1% fsd
Stability (span)
with time* < ±3% fsd / yr
with temperature*** < ±3% fsd
with humidity < ±2% fsd
Weight 190g
Construc. MaterialsPolyphenylene Sulphide (PPS)
I.P. (NEMA) RatingIP65 (standard), IP67 (with weather protection fitted)
Certification Details
(ATEX/ IECEx)
II 2 GD Ex d IIC Gb T85ºC
Tamb -40ºC to +55ºC
II 2 GD Ex d IIC Gb T100ºC
Tamb -40ºC to +70ºC
II 2 GD Ex d IIC Gb T135ºC
Tamb -40ºC to +80ºC
tb IIIC A21 Db IP67
Baseefa08ATEX0265X
IECEx BAS08.0068X
Other CertificationsRussian: GOST
Applicable StandardsThis product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1

* = % of range (fsd) per year
** Over operating temperature range
*** = % of applied concentration

Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES > HONEYWELL SENSEPOINT
    00780-A-0100 Sensepoint Terminal Housing - Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved ..

  • ACCESSORIES > HONEYWELL XCD
    02000-A-1640 Honeywell Nylon Weather Protection for Combustible/MPD Sensor with test/calibration gas port. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> LEL CATALYTIC BEAD :    34 Items found.
BTN-3042
(6723)

PROSENSE  BTN-3042

Prosense BTN-XY42 Gas Detector with Catalytic sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Pentane, nButane) with range 0-100% LEL. ABS plastic housing. 2 Alarms and 1 Fault Relays and optional Modbus RS485 RTU output. IP54.

Configure

$117.00 
20100075
(6451)

DEGA  20100075

DEGA NB III Gas Detection Transmitter with Catalytic Sensor for Methane (CH4), LPG or Hydrogen (H2) with range 0-100% LEL. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$316.80 
20100074
(6490)

DEGA  20100074

DEGA NB III Gas Detection Transmitter with Catalytic Sensor for Explosive and Flammable gases with range 0-100% LEL. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$316.80 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$333.46 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval. IP65, Optional IP66 Adaptor.

Configure

$351.00 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$400.76 
30100068
(6452)

DEGA  30100068

DEGA NS II Gas Detection Transmitter with Catalytic Sensor for Hydrocarbons, Methane (CH4) or Hydrogen (H2) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$506.88 
30100070
(6504)

DEGA  30100070

DEGA NS II Gas Detection Transmitter with Catalytic Sensor for LPG with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$506.88 
30100157
(6453)

DEGA US  30100157

DEGA NS II LCD RE Gas Detector with Catalytic Sensor for Hidrocarbons, Methane (CH4), Propane LPG (C3H8) or Hydrogen (H2) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) includes 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54. ATEX Zone 2.

Configure

$552.96 
20100168
(6686)

DEGA  20100168

DEGA NB III LCD Gas Detection Transmitter with Catalytic Sensor for Hydrocarbons with range 0-100% LEL. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$570.24 
20100169
(6687)

DEGA  20100169

DEGA NB III LCD Gas Detection Transmitter with Catalytic Sensor for Methane (CH4), LPG or Hydrogen (H2) with range 0-100% LEL. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$570.24 
SPC3-3355-200US
(2911)

INTEC  SPC3-3355-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Methane, Methyl Ethyl Ketone, n-Butane, n-Octane, n-Pentane, Propane, Acetone, Jet A, JP8 and Toluene.

Configure

$611.40 
SPC3-3380-200US
(2910)

INTEC  SPC3-3380-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Ammonia, Ethylene, Ethyl Alcohol, Ethyl Acetate, Benzene, n-Hexane, n-Heptane, Hydrogen, Isopropyl Alcohol and Methanol.

Configure

$611.40 
PQD-3035
(6718)

PROSENSE  PQD-3035

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx and SIL2 approvals. IP65, Optional IP66 Adaptor.

Configure

$612.00 
GDS-48-1-71-06
(343)

GDS  GDS-48-1-71-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Catalytic Bead for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. CSA Certified for Div. 1 Explosion Proof.

Configure

$760.00 
30100159
(6532)

DEGA  30100159

DEGA NS II LCD RE Gas Detector with Catalytic Sensor for LPG with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$760.32 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$819.00 
40100157
(6611)

DEGA  40100157

DEGA NS III LCD RE Gas Detector with Catalytic Sensor for Hydrocarbons (HC), Methane (CH4), LPG or Hydrogen (H2) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP64 (Optional IP66). ATEX Zone 1.

EX-_GENL-100L-O
(6021)

MACURCO  EX-GENL-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Combustible Gases 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1. Optional calibration to Methane, Propane, Pentane, Methanol, Hydrogen, Ethylene, Acetone, Butanol, Butane, Benzene and other combustibles.

Configure

$935.00 
SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,075.71 
Page: 1 | 2 | All