Medc Xb12b02406rndnnnnn | Beacons | Atex | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   XB12B02406RNDNNNNN

SKU# (1596)



MEDC XB12B_02406RNDNNNNN

ALARM SIGNAL DEVICES / ATEX
BEACONS

$1,337.03  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC XB12 Xenon Beacon (21 Joules), Exd, Weatherproof, IP66 and IP67, designed for use in potentiallyexplosive atmospheres and harsh environmental conditions. –55 DegreesC to +70 DegreesC. ATEX Certified, Ex II 2 G, Ex d IIB T4/T5/T6 Gb. Inmetro, CUTR, IECEx and CQST versions also available.

ATEX   IECEX

XB12B02406RNDNNNNN   
1,337.03

Certification
Voltage
Lens Colour
Lens Guard
Fixings
Earth Continuity
Label
Options
Options
Finish

   9 Weeks  ]
251 Variants of base SKU / 30 Shown below

These high output certified beacons have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required.

The beacon housing is manufactured completely from a U.V. stable, glass reinforced polyester.

Stainless steel screws and mounting bracket are incorporated ensuring a totally corrosion free product.

Units can be painted to customer specification and supplied with identification labels.

FEATURES

  • Zone 1 and Zone 2 use.
  • Ex d IIB T4/T5/T6
  • ATEX approved, Ex II 2G.
  • BASEEFA certified.
  • UL Listed for USA and Canada
    • Hazardous locations:
      • Class I, Div 2, Groups C & D.
      • Class I, Zones 1 & 2, AExd IIB T4 & T5.
    • Ordinary locations: Visual-Signal Device.
    • Marine Listed
  • IECEx certified Gb
  • GOST ‘R’ & ‘K’ certified.
  • Chinese (CQST) certified.
  • Inmetro certified.
  • High Output (21 Joules).
  • IP66 and IP67.
  • Certified temperature: –55°C to +70°C.
  • Corrosion resistant GRP.
  • Optional stainless steel backstrap.
  • Various lens colours.
  • Optional lens guard.
  • Optional telephone initiation.
  • Twin replaceable tubes.

Specification
Certification Certified to IEC60079-0, IEC60079-1
Certified to EN60079-0, EN60079-1
ATEX Cert. No. BAS99ATEX1296
Ex II 2 G Ex d IIB T4/T5/T6 Gb
IECEx Cert. No. IECEx BAS 10.0094
Ex d IIB T4/T5/T6 Gb
UL Listed for USA and Canada:
Hazardous locations:
Class I, Div 2, Groups C & D and
Class I, Zones 1 & 2, AExd IIB T4 & T5.
UL Listing No: E187894.
Ordinary locations: Visual-Signal Device.
Marine Listed
UL Listing No. S8128.
GOST ‘R’ Certification: 1Exd IIB T4/T5.
GOST ‘K’ Certification: Exd IIB T4/T5.
Chinese (CQST) Certification: Exd IIB T4/T5.
Inmetro Certification: BR-Ex d IIB T3/T4/T5/T6.
Material Body: Glass reinforced polyester.
Lens: Toughened Glass
Cover Screws + Backstrap: Stainless steel 316.
Finish: Natural black or painted to customer specification.
Weight: 7.0kg.
Certified Temp: Exd -55°C to +70°C (T4). -55°C to +55°C (T5).
-55°C to +40°C (T6).
UL -55°C to +70°C (Hazardous Locations).
-55°C to +55°C (Ordinary Locations).
Ingress Protection: IP66 & IP67.
Fire Retardancy: GRP is fire retardant to ISO 1210.
Earth Continuity: Optional for metal glands provided via a brass plate
(not available in UL version).
Terminals: 6 x 6.0mm2.
Telephone initiation: Initation by telephone ringing tone.
Labels: Duty/Tag Label optional.
Entries: 2 x M20 ISO EExd.
2 x 1/2" NPT UL.
>
Electrical Ratings:
d.c. a.c. 50/60Hz
Voltage 24 110 240
XB12 Tube Energy (Joules) 21 21 21
Peak Current Consumption (mA) 1400 350 185
Effective Intensity (Cd) 355 355 355
Peak Intensity (Cd) 123691 123691 123691
Power Consumption (W) 33.6 38.5 44.4

NOTE: The Cd figures are for a clear lens @ 1Hz flash rate.

Multiplying Factor for Colored Lenses:
Red Blue Amber Green Yellow
0.15 0.12 0.51 0.49 0.86

The photometric data has been verified by BSI. A report is available if required.

Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> BEACONS :    110 Items found.
D2xB1LD2DC024MN0H1R/C
(6409)

E2S  D2xB1LD2DC024MN0H1R/C

E2S D2xB1LD2-H Haz Loc auto-synchronizing LED Light/Beacon tested to UL1971. Up to 180cd. 24vdc. Three flashing modes. 2 × 1/2” NPT, 2 x M20x1.5, 1 × 3/4” NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1LD2DC024CN1A1R/C
(6408)

E2S  D2xB1LD2DC024CN1A1R/C

E2S D2xB1LD2 Haz Loc LED Beacon Warning Light tested to UL1638. Up to 180cd. Five flashing modes. Dual 1/2"NPT and dual M20 side entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1X05DC024MN1A1R/C
(6412)

E2S  D2xB1X05DC024MN1A1R/C

E2S D2xB1X05 Haz Loc 5 Joule Xenon Strobe Beacon tested to UL1638. Up to 250cd. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xB1X10DC024MN1A1R/C
(6413)

E2S  D2xB1X10DC024MN1A1R/C

E2S D2xB1X10 Haz Loc 10 Joule Xenon Strobe Warning Light tested to UL1638. Up to 500cd. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

MBX05AC115AN1A1G/A
(3632)

E2S  MBX05AC115AN1A1G/A

E2S MBX05 5 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for harsh environments. Robust, fire retardant, IP66 & IP67 housing. Stainless Steel guard and fixings. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

4375S-120_-A
(7228)

TOMAR  4375S-120-A

Tomar Electronics 4375S Hazardous Location Warning Light with 10000 hours xenon strobe lamp. 120-240 VAC model, or 12-74 VDC. NEMA 4X housing. IP66. UL Listed and CSA Certified for Class I, Div 2, Groups A, B, C, and D; Class II, Div 2, Groups F and G; Class III.

Configure

$541.25 
D2xB1XH1DC024MN0A1R/C
(6410)

E2S  D2xB1XH1DC024MN0A1R/C

E2S D2xB1XH1 Haz Loc 5 Joule Xenon Strobe Beacon tested to UL1971. Up to 250cd. 24vdc. Four flashing modes. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

4375L-24_-A
(7227)

TOMAR  4375L-24-A

Tomar Electronics 4375L Hazardous Location Warning Light with 100000 hours LED array. Steady-burn and Single or Double Flash mode. 120-240 VAC model, or 24 VAC/DC. NEMA 4X housing. IP66. UL Listed and CSA Certified for Class I, Div 2, Groups A, B, C, and D; Class II, Div 2, Groups F and G; Class III.

Configure

$564.41 
E2xB05AC115CN1A1B/A
(4421)

E2S  E2xB05AC115CN1A1B/A

E2S E2xB05 5 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for the harshest of environments. PPS & ABS housing. Stainless Steel guard. 24VDC.. UL/cULs Approved for Class I Div 2 and Class 2 Div 2. ATEX and IECEx Approved.

E2XBL2AC115CN1A1B/A
(6418)

E2S  E2XBL2AC115CN1A1B/A

E2S E2xBL2 Multi-function LED Beacon & Status Light tested to UL1638A. Up to 160cd. Five flashing modes. Dual M20x1.5 or 1/2"NPT entries. IP66/IP67. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2xB10AC115CN1A1B/A
(4422)

E2S  E2xB10AC115CN1A1B/A

E2S E2xB10 10 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for the harshest of environments. PPS & ABS housing. Stainless Steel guard. 24VDC. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

D2xB1XH2DC024MN0A1R/C
(6411)

E2S  D2xB1XH2DC024MN0A1R/C

E2S D2xB1XH2 Haz Loc 10 Joule Xenon Strobe Beacon tested to UL1971. Up to 500cd. 24vdc. Four flashing modes. 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT entries. IP66. UL/cUL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

MBX10DC024CN1A1R/R
(3633)

E2S  MBX10DC024CN1A1R/R

E2S MBX10 10 Joule Xenon Strobe Beacon with 1Hz flash rate suitable for harsh environments. Robust, fire retardant, IP66 & IP67 housing. Stainless Steel guard and fixings. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

FB15UW024060RNDNNNN
(4197)

MEDC  FB15UW024060RNDNNNN

MEDC FB15 (Filament) Steady Beacons, Exd, Weatherproof, IP66 and IP67, designed for use in potentiallyexplosive atmospheres and harsh environmental conditions. UL Listed for ordinary locations version.

Configure

$770.30 
BEXBG05E115AC-AM
(3528)

E2S  BEXBG05E115AC-AM

E2S BExBG05E flameproof Xenon Beacon 5 Joule. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22. Glass lens and Stainless Steel guard. Two M20 cable entries. IP66. ATEX, IECEx and GOST-R (2ExdeIICT4).

BEXBG05DPAC115AB1A1R/A
(3527)

E2S  BEXBG05DPAC115AB1A1R/A

E2S BExBG05 Explosion and Flame Proof 5 Joule Xenon Beacon suitable for Zone 1, 2, 21 & 22. LM6 aluminium enclosure. Glass lens and Stainless Steel guard. IP66/67. IECEx, ATEX, Ex EAC and INMETRO approvals.

IS-DL105L-R/R
(6426)

E2S  IS-DL105L-R/R

E2S IS-DL105L 105dB(A) Intrinsically Safe Alarm Sounder and LED Beacon. 49 alarm tones and 3 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.

FB15B_024060RNDNNNN
(1606)

MEDC  FB15B024060RNDNNNN

MEDC FB15 (Filament) Steady Beacons, Exd, Weatherproof, IP66 and IP67, designed for use in potentiallyexplosive atmospheres and harsh environmental conditions. ATEX Certified, Ex II 2GD, EExd IIC T3/T4. IECEx, CUTR and Inmetro also available.

Configure

$833.97 
FB15UL024060RNDNNNN
(4196)

MEDC  FB15UL024060RNDNNNN

MEDC FB15 (Filament) Steady Beacons, Exd, Weatherproof, IP66 and IP67, designed for use in potentiallyexplosive atmospheres and harsh environmental conditions. UL Listed for Class I, Div 2, groups A,B,C,D.

Configure

$833.97 
BEXBG10E115AC-AM
(3530)

E2S  BEXBG10E115AC-AM

E2S BExBG10E flameproof Xenon Beacon 10 Joule. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22. Glass lens and Stainless Steel guard. Two M20 cable entries. IP66. ATEX, IECEx and GOST-R (2ExdeIICT4).

Page: 1 | 2 | 3 | 4 | 5 | 6 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.