Intec At-2064-a-000-0 | Refrigerants | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTEC   AT-2064-A-000-0

INTEC AT-2064-A-000-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Intec Controls PolyGard AT-2000 V3 Analog Gas Transmitter for Refrigerants (HCFC and HFC) 0-500 / 0-1000 / 0-2000 ppm (infrared). 2 relay outputs, 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified. Factory configured for either R123, R125, R410a, R22, R134a, R404a or R407a

AT-2064-A-000-0   
1,251.00

Gases
Options
Gas Range

   In Stock  ]

APPLICATION

For leak detection in commercial and industrial cooling systems, with refrigerant gases (HCFC and HFC) as cooling agents. Flexible 18-28 VAC/ DC power and industry standard current or voltage output signals, for easy installation and connection to local controllers, annunciators, or building automation systems.

FEATURES
  • Continuous monitoring
  • Dual-beam, non-dispersive infrared (NDIR) sensor for high selectivity and long-term reliability
  • ± 20 ppm accuracy (± 40 ppm for 0-2000 ppm range)
  • AC or DC powered
  • (0)4-20 mA, (0)2-10 VDC output, selectable
  • Life expectancy > 10 yrs.
  • Calibration interval > 5 yrs.
  • Modular plug-in technology
  • NEMA 4X, high-impact polycarbonate enclosure, provides protection from dirty and wet environments
  • 1/2" conduit adapter included
  • Two-stage relay output control, optional

Specifications
Electric
Power supply 18-28 VAC/DC, polarity protected
Power consumption 45 mA (1.1 VA), max.
Sensor Performance
Gas detected R22, R123, R125, R134a, R404a, R407a (factory configured)
Sensor element Dual-beam, non-dispersive infrared (NDIR)
Range 0-500 ppm for R123 only
0-1000 ppm
0-2000 ppm
Accuracy 0-500 / 0-1000 ppm: ± 20 ppm, max.
0-2000 ppm: ± 40 ppm, max.
Response time t 90 < 30 sec.
Long-term zero-point drift < 2% f.s. range/year
Long-term output drift < 3% f.s. range/year
Sensor life expectancy > 10 years
Recommended cal. interval > 5 years
Type of Control
General Continuous analog output proportional to sensor measurement input
Analog output (0)4-20 mA, load ≤ 500 Ω, or (0)2-10 VDC, load ≥ 50 kΩ
Optional contact outputs (2) relays, potential free
Environmental
Permissible ambient working temperature 14°F to 104°F (-10°C to 40°C)
Permissible ambient storage temperature -4°F to 104°F (-20°C to 40°C)
Permissible ambient humidity 0 to 95% RH, non condensing
Permissible ambient working pressure 1 bar -20%/+10%
Physical
Enclosure (panel)
-material Polycarbonate, UL 94-HB, fire-retardant
-color Light gray
-protection NEMA 4X (IP65)
-installation Wall (surface) mounted
-enclosure approval UL Listed, E208470
CSA Certified, E208470
Dimensions (H x W x D) 5.12 x 3.70 x 2.25 in. (130 x 94 x 57 mm)
Cable entry 1/2 in. conduit adapter included
Wire size Min. 24 AWG (0.25 mm 2 )
Max 14 AWG (2.5 mm 2 )
Wire distance mA output: approx. 1500 ft. (500 m)
VDC output: approx. 600 ft. (200 m)
Physical
Weight 1.1 lbs. (0.5 kg)
Calibration Adjustment via onboard zero push-button and gain potentiometer
Approvals / Listings
-unit rating NRTL Certification to STD ANSI/UL 61010-1
CE
EMV-Compliance 2004/108/EWG, low voltage directives 73/23/EWG
-relays (R1-R2) UL Recognized, E41515
CSA, C22.2 No. 0, No. 14 (File No. LR31928)
Warranty Two years material and workmanship, 12 months normal exposure for sensor element

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> REFRIGERANTS :    18 Items found.
RD-VRF-R32____-_24
(7186)

MACURCO  RD-VRF-R32-24

Macurco RD-VRF Refrigerant Leak Detector with NDIR Sensor 0-5000 ppm, Alarm levels 1000 ppm & 2000 ppm. Includes 2 SPDT (Form C) Relays, 83 dB Alarm Buzzer and Modbus RTU outputs. Multicolor LED status indicator, life expectancy >8 years. 24V or 120V.

Configure

$553.19 
P-7231
(6787)

PROSENSE  P-7231

Prosense P-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$746.46 
P-9233
(7139)

PROSENSE  P-9233

Prosense P-9233 Gas Detector with Infrared sensor for R4448A with range 0-2000ppm Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-7231-1/2
(6960)

PROSENSE  PQN-7231-1/2

Prosense PQN-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$926.64 
PQD-7231-1/2
(6748)

PROSENSE  PQD-7231-1/2

Prosense PQD-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,081.08 
PQD-9233-1/2
(7138)

PROSENSE  PQD-9233-1/2

Prosense PQD-9233 Gas Detector with Infrared sensor for R4448A 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
GG-VL2-R
(4138)

CALIBRATION TECHNOLOGIES  GG-VL2-R

CTI GG-VL2-R Refrigerant Vent Line for R22, R134a, R404A, R507A and other CFC / HFC / HCFC gases 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless steel enclosure.

Configure

$1,434.00 
GG-_R22-0500
(2969)

CALIBRATION TECHNOLOGIES  GG-R22-0500

CTI GasGuard R Refrigerant Infrared Sensor for R22, R134a, R401a, R402a, R404a, R407a, R407c, R422d, R434a and R507a. (0-500 or 0-3000 ppm) for gas leak detection in refrigeration systems, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,519.00 
VL-F7-R22-N4-LPA-MK
(3717)

HONEYWELL  VL-F7-R22-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for R22 Refrigerant 0 to 1,000 ppm. Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
IR-F9-R22-1000-COM
(6594)

HONEYWELL  IR-F9-R22-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R22 with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R404a-1000-COM
(6590)

HONEYWELL  IR-F9-R404a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R404a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R134a-1000-COM
(1540)

HONEYWELL  IR-F9-R134a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R134a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R422d-1000-COM
(6593)

HONEYWELL  IR-F9-R422d-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R422d with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R407a-0500-COM
(6595)

HONEYWELL  IR-F9-R407a-0500-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R407a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-HFO1234yf-1000-COM
(6596)

HONEYWELL  IR-F9-HFO1234yf-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant HFO1234yf with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R410a-1000-COM
(1545)

HONEYWELL  IR-F9-R410a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R410a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,074.57 
IR-F9-R507a-1000-COM
(6592)

HONEYWELL  IR-F9-R507a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R507a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,074.57 
GG2SAXXX-X-R12
(5014)

ION SCIENCE  GG2SAXXX-X-R12

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Refrigerants (R12, R1301, R134a, R22, R11, R502, R404a, R407c, R410a or R507). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***