Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
CLASS I DIV 1 > all :    26 Items found.
IS-MA1-R
(3689)

E2S  IS-MA1-R

E2S IS-mA1 IS-minialarm compact Alarm Sounder 100dB(A). 16-28VDC. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class 1 Zone 0.

IS-A105N-G
(3687)

E2S  IS-A105N-G

E2S IS-A105N high output Alarm Sounder 105dB(A). 16-28VDC. Stainless Steel fixings. IP66. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class 1 Zone 0.

IS-MB1-R/A
(3690)

E2S  IS-MB1-R/A

E2S IS-mB1 IS-minialite compact LED Beacon. 16-28VDC. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class I Zone 0.

D1xL1FR008AB1A1R
(4411)

E2S  D1xL1FR008AB1A1R

E2S D1xL1F 15W PA Loudspeaker with re-entrant flare horn. High SPL. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

IS-L101L-R/R
(3688)

E2S  IS-L101L-R/R

E2S IS-L101L LED Beacon. Provides a bright flashing warning signal. 16-28VDC. Stainless Steel fixings. IP66. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class I Zone 0.

D1xL2FR008AB1A1R
(4412)

E2S  D1xL2FR008AB1A1R

E2S D1xL2F 25W PA Loudspeaker with re-entrant flare horn. High SPL. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

IS-MC1-R/A
(3691)

E2S  IS-MC1-R/A

E2S IS-mC1 IS-minialert compact combined Alarm Sounder 100dB(A) and LED Beacon. 16-28VDC. Zener barrier or galvanic isolator required to run both units. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class 1 Zone 0.

D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
D1XB2X05DC024MN1A1R/R
(6430)

E2S  D1XB2X05DC024MN1A1R/R

E2S D1xB2X05 Explosion Proof 5 Joule Xenon Strobe Beacon for Class I/II Div 1 Zone 1, 2, 21 & 22. 4 flash rates. 2×3/4"NPT & 2xM20x1.5 side and 1×3/4"NPT pendant entries. Type 4/4x corrosion proof LM6 aluminium enclosure. IP66. UL, ATEX, IECEx and SIL1/2 approvals.

D1XB2XH2DC024MN0H1R/C
(6406)

E2S  D1XB2XH2DC024MN0H1R/C

E2S D1xB2XH2 Explosion Proof Auto Sync 21 Joule (190cd) Xenon Strobe Beacon tested to UL1971. Conduit or surface mounting. Four flash rates. Dual 3/4"NPT and dual M20 side entries. 24Vdc. IP66. UL/cUL/ULC approved for Class I/II Div 1, Class I Zone 1/Zone 21.

D1xS1RDC024AB1A1R
(4409)

E2S  D1xS1RDC024AB1A1R

E2S D1xS1R 115dB(A) high output Radial Alarm Horn Sounder with an omni-directional horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xS1FDC024AB1A1R
(4408)

E2S  D1xS1FDC024AB1A1R

E2S D1xS1F 117dB(A) high output Alarm Horn Sounder with re-entrant flare horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

D1XB2LD2DC024MN1A1R/R
(6429)

E2S  D1XB2LD2DC024MN1A1R/R

E2S D1xB2LD2 Explosion Proof LED Multi-function Beacon for Class I/II Div 1 Zone 1, 2, 21 & 22. 5 flash rates. 2×3/4"NPT & 2xM20x1.5 side and 1×3/4"NPT pendant entries. Type 4/4x corrosion proof LM6 aluminium enclosure. IP66. UL, ATEX, IECEx and SIL1 approvals.

D1XB2X10DC024MN1A1R/R
(6431)

E2S  D1XB2X10DC024MN1A1R/R

E2S D1xB2X10 Explosion Proof 10 Joule Xenon Strobe Beacon for Class I/II Div 1 Zone 1, 2, 21 & 22. 4 flash rates. 2×3/4"NPT & 2xM20x1.5 side and 1×3/4"NPT pendant entries. Type 4/4x corrosion proof LM6 aluminium enclosure. IP66. UL, ATEX, IECEx and SIL1/2 approvals.

D1XB2XH1DC024MN0H1R/C
(6405)

E2S  D1XB2XH1DC024MN0H1R/C

E2S D1xB2XH1 Explosion Proof Auto Sync 10 Joule (86cd) Xenon Strobe Beacon tested to UL1971. Conduit or surface mounting. Four flash rates. Dual 3/4"NPT and dual M20 side entries. 24Vdc. IP66. UL/cUL/ULC approved for Class I/II Div 1, Class I Zone 1/Zone 21.

D1XB2X15DC024MN1A1R/R
(6428)

E2S  D1XB2X15DC024MN1A1R/R

E2S D1xB2X15 Explosion Proof 15 Joule Xenon Strobe Beacon for Class I/II Div 1 Zone 1, 2, 21 & 22. 4 flash rates. 2×3/4"NPT & 2xM20x1.5 side and 1×3/4"NPT pendant entries. Type 4/4x corrosion proof LM6 aluminium enclosure. IP66. UL, ATEX, IECEx and SIL1/2 approvals.

D1xS2FDC024AB1A1R
(4410)

E2S  D1xS2FDC024AB1A1R

E2S D1xS2F 125dB(A) high output Alarm Horn Sounder with re-entrant flare horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

D1XB2X21DC024MN1A1R/R
(6432)

E2S  D1XB2X21DC024MN1A1R/R

E2S D1xB2X21 Explosion Proof 21 Joule Xenon Strobe Beacon for Class I/II Div 1 Zone 1, 2, 21 & 22. 4 flash rates. 2×3/4"NPT & 2xM20x1.5 side and 1×3/4"NPT pendant entries. Type 4/4x corrosion proof LM6 aluminium enclosure. IP66. UL, ATEX, IECEx and SIL1/2 approvals.

D1xC1X05FDC024AB1A1R/A
(4413)

E2S  D1xC1X05FDC024AB1A1R/A

E2S D1xC1X05F Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC1X05RDC024AB1A1R/A
(4414)

E2S  D1xC1X05RDC024AB1A1R/A

E2S D1xC1X05R Radial Alarm Horn 115dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Div 1, Zone 1 & 20 applications. UL and CSA Approved.