Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
GAS DETECTORS (EXPLOSION-PROOF) > HYDROGEN CYANIDE :    16 Items found.
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20 mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7534
(6789)

PROSENSE  P-7534

Prosense P-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,210.42 
PXN-7534-1/2
(7346)

PROSENSE  PXN-7534-1/2

Prosense PXN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$1,335.94 
1100ALD-109020/30P-L0
(6912)

RC SYSTEMS  1100ALD-109020/30P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20 mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class I Div 2 (Non-Incendive).

Configure

$1,338.96 
PQN-7534-1/2
(6962)

PROSENSE  PQN-7534-1/2

Prosense PQN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,470.44 
PXD-7534-1/2
(7345)

PROSENSE  PXD-7534-1/2

Prosense PXD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25 ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. LCD Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$1,488.37 
41001AL-0-1020/0030P/L0
(7165)

RC SYSTEMS  41001AL-0-1020/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20 mA loop powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class I Div 2 (Non-Incendive).

Configure

$1,563.63 
51001AL-0-1020/30P/L0
(7128)

RC SYSTEMS  51001AL-0-1020/30P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN2 smart Electrochemical sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,619.48 
PQD-7534-1/2
(6750)

PROSENSE  PQD-7534-1/2

Prosense PQD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,640.79 
961-130026-030C
(6366)

DETCON  961-130026-030C

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

2100AL-0-9020/30P/L0
(127)

RC SYSTEMS  2100AL-0-9020/30P/L0

RC Systems SenSmart 2100 2 wire 4-20 mA Loop Powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class I Div 2 (Non-Incendive).

Configure

$1,814.28 
31001AL-0-9020/30P/L0
(5783)

RC SYSTEMS  31001AL-0-9020/30P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class I Div 2 (Non-Incendive).

Configure

$1,992.21 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20 mA loop, LCD Display, 0-30ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$2,062.03 
967-131390-030A
(6091)

DETCON  967-131390-030A

Detcon DM-700-HCN Electrochemical Smart Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div 1, Groups B, C, & D. CSA and ATEX approvals. Optional Alarm Relays, HART.

6100AL1-0-1020/0030P
(7007)

RC SYSTEMS  6100AL1-0-1020/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-44' smart transmitter and GEN2 smart Electrochemical sensor. Includes Color TFT Display, 4-20 mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,414.28 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20 mA HART loop, backlit LCD Display with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL2 . Optional Alarm Relays, Modbus, Fieldbus.

Configure

$2,512.00 