Gasdetectorsusa.com: Atex - Call Points
Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
ATEX > CALL POINTS :    18 Items found.
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

BExCP3A-PB-ST-NL-RD
(4084)

E2S  BExCP3A-PB-ST-NL-RD

E2S BExCP3A-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PB-ST-NL-06
(5137)

E2S  BExCP3B-PB-ST-NL-06

E2S BExCP3B-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.