Gasdetectorsusa.com: Atex - Call Points
Acd, Aimsafety, Ams, Analytical Technology, Automation Direct, Autronica, Bw, Calibration Technologies, Cool Air, Delphian, Detcon, Det-tronics, E2s, Esp Safety, Felix, Fhf, Forensics Detectors, Gas Clip, Gas Detectors Usa, Gasco, Gds, Harvard, Honeywell, Industrial Scientific, Infrared Industries, Intec, Interscan, Ion Science, Ivc, Kwikdraw, Macurco, Medc, Mpower, Mru, Notifier, Nova, Portagas, Prosense, Rc Systems, Rhino, Simplex Tyco, Simtronics, Solo, Spectrex, System Sensor, Tomar, Uniphos, United Security
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
ATEX > CALL POINTS :    24 Items found.
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PBSSLAB1A1R
(4081)

E2S  IS-CP4A-PBSSLAB1A1R

E2S IS-CP4-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PTSSLAB1A1R
(4082)

E2S  IS-CP4A-PTSSLAB1A1R

E2S IS-CP4-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3ABGSSLAB1A1RN06
(5136)

E2S  BExCP3ABGSSLAB1A1RN06

E2S BExCP3-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

GNEXCP6A-BG-SDNAN1A1RN06
(6443)

E2S  GNEXCP6A-BG-SDNAN1A1RN06

E2S GNExCP6-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BExCP3APTSSLAB1A1RN06
(5138)

E2S  BExCP3APTSSLAB1A1RN06

E2S BExCP3-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3APBSSLAB1A1RN06
(5137)

E2S  BExCP3APBSSLAB1A1RN06

E2S BExCP3-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

GNEXCP6A-PT-SDLAN1A1RN06
(6445)

E2S  GNEXCP6A-PT-SDLAN1A1RN06

E2S GNExCP6-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNExCP6A-PB-SDLAB1A1RN06
(6444)

E2S  GNExCP6A-PB-SDLAB1A1RN06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$499.53 
BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$547.35 
BG2INN1_NR
(4151)

MEDC  BG2INN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. EExia IIC T4, ATEX Approved Ex II 1G. IP66 and IP67.

Configure

$574.73 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R and CQST approvals also available.

Configure

$736.75 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR ... more

Configure

$832.84 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R and CQST approvals also available.

Configure

$916.13 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR and CQST certifications also ... more

Configure

$1,031.57 
STEXCP8PMSDLAS1A1RN
(6462)

E2S  STEXCP8PMSDLAS1A1RN

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, ... more

STExCP8PBSDNAS1A1RN
(6461)

E2S  STExCP8PBSDNAS1A1RN

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and ... more

STExCP8BGSDLAS1A1RN
(6460)

E2S  STExCP8BGSDLAS1A1RN

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and ... more

SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,832.27 
Page: *1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.