Gds C2-20-010-04/00-000-00/0-0-0-0-0/0-0 | Oxygen | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   C2-20-010-04/00-000-00/0-0-0-0-0/0-0

GDS C2-20-010-04/00-000-00/0-0-0-0-0/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Oxygen (O2) sensor with range 0-25% Vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Inquiry



The C2 Protector Display & Alarm Controller provides signal conditioning, display and alarm functions for one or two critical input variables.

Versatile

Designed to provide low-cost direct monitoring for one or two gas sensors or flame detectors, the C2 Protector controller offers a highly-integrated, complete solution for detection of hazardous conditions. Versatile input signal conditioning options allow direct connection of any GDS Corp electrochemical sensor, and local or remote support for any GDS Corp combustible, PID or infrared sensor. Both channels can be configured to accept analog inputs from sources such as the GDS-49 Sensor Transmitter, GDS-IR Point Infrared Gas Detector or any standard 4-20mA source.

Additional C2 options include 5A SPDT discrete relays, 4-20mA outputs, light stacks and audible annunciators.

One popular application for the C2 is as a dual gas detector equipped with one local combustible sensor and one local toxic sensor. Alternatively, two combustible locations may be monitored with one sensor local and another remote.

Real-Time Display

A large graphic LCD screen displays input data as calibrated engineering units, bargraphs or 30-minute trends. Three adjustable alarm levels per channel, combined with programmable relays with voting logic allows flexible control of beacons, horns and other warning devices. Highly visible red and yellow LEDs visually indicate alarm status at all times.

Digitally Connected

An optional RS-485 MODBUS® slave port allows multiple C2 controllers to be multi-dropped on a single data highway. The C2 Protector controller is also 100% compatible with the ProtectorHMI Visualization and Historian software that can monitor, display and record data from up to ten C1 Protector or C2 Protector controllers.

Reliability

The C2 Protector controller is CSA certified to CSA C22.2 No. 152 for combustibles and Class I, Division 2, Groups A, B, C, D for use in hazardous areas. An optional NEMA 7 enclosure allows use in Class I Div 1 areas. Up to twelve watts of 24 VDC power is available for auxiliary devices or transmitters.

FEATURES

  • Accepts one or two direct-connect local or remote sensors or 4-20mA
  • Large LCD display shows values, bar-graph and trend data
  • Two programmable 5A SPDT common relays for Alarm 1, Alarm 2, Horn or FAULT
  • Optional 6x relay board for perchannel SPDT contacts
  • Optional dual channel 4-20mA board for current loop output
  • Operates on either +24VDC or 117/240VAC 50/60Hz
  • ACK button silences HORN without affecting alarm relays
  • Relay voting logic reduces need for external hardware
  • Touch and magnetic keys for non-intrusive operation in XP areas
  • Pushbutton zero and span calibra tion for directly connected sensors
  • NEMA 4x approved for Class 1 Div 2 area without purge
  • MODBUS® slave port for easy interface from master devices
  • CSA certified to C22.2 No 152 for combustible gas detection and approved for Class 1, Div 2 Groups A, B, C, D
  • Manufactured in USA

C2 Protector SPECIFICATIONS
Power Input: 24VDC (12 Watt MAX) 85-240 VAC power supply included
Display Backlit 128x64 pixel LCD shows trend, bargraph and engineering units; flashing alarm LEDs indicate alarm status
Input Inputs available for dual catalytic bead LEL, dual toxic / O2, one each catalytic bead & toxic / O2, and dual 4-20mA
MODBUS I/O Optional slave mode RS-232 or RS-485 MODBUS interface
Relay Output Two common output relays configurable for A1, A2, FAIL & HORN ; 5A @ 30VDC / 240VAC resistive load
Analog Output Optional dual channel 4-20mA current loop. Max loop R is 800 ohms with nominal 24VDC
Audible Output Optional 100db alarm (NEMA 4X only)
Temp -25°C to +50°C operating
Housing NEMA 4X approved for Class 1 Div 2 Groups A, B, C, D
NEMA 7 wall-mount approved for Cls 1 Div 1 Groups B, C, D
Dimensions NEMA 4X Non-metallic: 11.25” x 13.31” x 7.25” (w-h-d)
NEMA 4X Painted or stainless: 9.84” x 13.65” x 6.2”
NEMA 7: 13” x 14.25” x 6.25”
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02;
UL 1604 / C22.2 No 213 (NEMA 4X = Div 2 Groups A, B, C, D;
NEMA 7 = Div 1 Groups B, C, D) EN55011 & EN61000 (CE Mark)
Warranty 2 years from date of purchase on electronics
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
1200-0550
(3202)

GDS  1200-0550

GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 18%. Balance Nitrogen. 103L Aluminium Cylinder.

1200-0549
(3201)

GDS  1200-0549

GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 8%. Balance Nitrogen. 103L Aluminium Cylinder.

10-0221/DUAL
(435)

RC SYSTEMS  10-0221/DUAL

RC Systems 4-20 mA 2-channel analog input board for ST-90 Dual Controllers



$268.83 
1200-0528
(3135)

GDS  1200-0528

GDS Gas Detector Calibration Gas Kit Oxygen (O2) 18%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0527
(3134)

GDS  1200-0527

GDS Gas Detector Calibration Gas Kit Oxygen (O2) 8%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

> OXYGEN :    30 Items found.
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$150.40 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-XL-Y
(6392)

BW  BWS1-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6524
(6806)

PROSENSE  PC3-6524

Prosense PC3-6524 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$481.90 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
P-6534
(6781)

PROSENSE  P-6534

Prosense P-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
SPSTAXO2
(1476)

HONEYWELL  SPSTAXO2

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. *** Replaces SPSTAXO1 ***

Configure

$648.84 
364-455-01-365-251-11
(6157)

DELPHIAN  364-455-01-365-251-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6534-1/2
(6954)

PROSENSE  PQN-6534-1/2

Prosense PQN-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

PQD-6534-1/2
(6742)

PROSENSE  PQD-6534-1/2

Prosense PQD-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
GG-O2-C0
(2968)

CALIBRATION TECHNOLOGIES  GG-O2-C0

CTI GasGuard O2 Oxygen Electrochemical Sensor (15-25% or 0-25%) for gas leak detection in food air quality monitoring, refrigeration systems, confined space and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1430
(1468)

HONEYWELL  2106B1430

Honeywell Sieger Sensepoint Gas Detector Transmitter for Oxygen (O2) 25% V/V with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109010/30P-L0
(6916)

RC SYSTEMS  1100ALD-109010/30P-L0

RC Systems SenSmart 1100 gas detector for Oxygen (O2) 0-25% with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
SPXCDULNO1
(662)

HONEYWELL  SPXCDULNO1

Honeywell XCD Sensepoint Gas Detector, Oxygen (O2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for oxygen (O2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 25%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
100-0008-SS/100-0015-O2
(4760)

ESP SAFETY  100-0008-SS/100-0015-O2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Oxygen (O2) 0-30% vol. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
S3KUL2-XNXXSO1SS
(682)

HONEYWELL  S3KUL2-XNXXSO1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring OXYGEN (O2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-25%VOL Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,497.56 
41001AL-0-1026/0030P/L0
(7177)

RC SYSTEMS  41001AL-0-1026/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.