Chlorguard Cg-d-2 | Chlorine | Emergency Shutoff | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CHLORGUARD   CG-D-2

CHLORGUARD CG-D-2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
ChlorGuard emergency valve shutoff system for CHLORINE (or other toxic/dangerous gas) storage drums. Includes: ChlorGuard 2-Drum Control Panel, Tools Kit, Pneumatic Airdrive Assembly and one remote emergency shutdown button.
System does not include Receiver Mounted Compressor

CG-D-2   
Please Email us your request for quote   

Valves to Close

   5 Weeks  ]
3 Variants of base SKU
Chlorine gas leaks

Product Features

  • Protects personnel from toxic gas. Peace of mind for end users
    • 99% of all leaks occur at valve take off
    • ChlorGuard shuts off at source
  • Originally designed by ICI Watercare in the early 1990’s
  • No requirement for scrubber systems
  • Proven track record with 1000 installations worldwide
  • Patented Design
  • Adaptable & compatible system for many cylinder/drum valves
  • User friendly equipment designed with maintenance in mind
  • Low running & maintenance costs
  • Telemetry feedback available
  • For use with compressed air or Nitrogen
  • Remote rapid shutdown
  • System test function available

As legislative pressures increase on toxic and other gas users, ChlorGuard offers a very flexible safeguard to prevent leaks and increase site safety

ChlorGuard is a flexible and cost-effective control measure that provides peace of mind for the end user in a 24/7 business. It also provides a very necessary level of control between the operational needs of the water provider and consumer needs

How The System Works The system incorporates a valve closing mechanism comprising a control panel, a number of air driven motors, a corresponding number of air filter regulator lubricators, and a corresponding number of telescopic propeller shafts.

The telescopic propeller shaft transmits the torque and rotation from the drive air motor to the drum valve. The propeller shaft has an integral drive dog mechanism. When the drive dog is in the locked position it transmits the torque and rotation along the shaft effecting valve closure. When the drive dog is in the unlocked position it enables the two ends of the shaft to be rotated independently. This allows easy connection and disconnection of the shaft; a means of releasing the torsion in the shaft when a drum valve has been driven closed; and manual re-opening of the drum valve.

A Dependable Drive Source Air powered motors are supplied with air under pressure via a compressor and a receiver. The compressor provides a constant, predetermined pressure between 20-25 psig sufficient to rotate the shaft assembly through as many revolutions as necessary to drive the handwheel from an open position to a fully closed position.

Easy Actuation Operation of the mechanism to close the valve may be triggered by the chlorine in air sensor within the enclosure housing the drum and/or it may be initiated manually by means of a user operable button located remotely from the storage vessels and/or chlorine detector. A further closing actuation can be achieved manually from the control panel.

If a Leak is Detected . . . . . . either by an operative (who will press the button) and/or by the detector, the system operates to rotate the handwheels and close the drum valves. In these circumstances, the pressure control valve is opened so that the air motors are operated to rotate the shaft assemblies, via the coupling devices, in the valve closing direction. The receiver is designed and arranged so that there is sufficient air pressure available at all times to operate the air motors, to the extent necessary to effect complete closure of all of the drum valves.

ChlorGuard Control Panel
ChlorGuard control panel
  • Fail-Safe system Normally Open Solenoid Valves (NO)
  • Up to 6 banks each with 3-way control
    • Isolate – Isolates compressed air
    • Manual – Shuts bank down immediately
    • Automatic – Shuts bank down from remote stop, gas detectors or key test
  • 110V or 230V
  • Telemetry available for the following:
    • Low pressure
    • Mains power failure
    • Bank lever not in automatic
    • Low battery
    • Alarm
  • 8 hours battery back up for both systems 24V (10 Ah)
  • Key test to enable frequent function testing

ChlorGuard drum shutoff airdrive assembly

ChlorGuard drum shutoff airdrive

  • Rotating pneumatic air motor
  • Drive mechanism is clamped onto the drum valve
  • Stainless steel fabrications with optional stand
  • Adaptable to fit non-standard cylinder valves
  • Torque requirements are preset for specific applications and can be manually – up to 40-50 Ft/lbs
  • Torque adjusted via pressure regulation (FRL)
  • Up to 6 motors supplied from one 6-way control panel
  • Flexible hose connection into main line

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.