Notifier Fst-951 | Intelligent | Thermal | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   FST-951

NOTIFIER FST-951
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

FST-951   
Please Email us your request for quote   

Version
Intelligent Bases

   2 Days  ]

The NOTIFIER® FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the FST-851 Series. A new modern, sleek, con- temporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations.

The series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as designated.

FEATURES

SLC LOOP:
  • Two-wire SLC loop connection
  • Unit uses base for wiring
ADDRESSING:
  • Addressable by device
  • Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.)
ARCHITECTURE:
  • Designed to meet UL 268 7th Edition
  • Sleek, low-profile, stylish
OTHER SYSTEM FEATURES:
  • Remote test feature from the panel
  • Walk test with address display
  • Low standby current
OPTIONS:
  • Remote LED output connection to optional RA100Z remote LED annunciator
Installation

FST-951 Series plug-in intelligent thermal detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector.

Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054.

NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet I56-1380 for device limitations between isolator modules and iso- lator bases.

Applications

Use thermal detectors for protection of property. For further informa- tion, refer to I56-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications.

Construction

These detectors are constructed of fire-resistant plastic. The FST- 951 Series plug-in intelligent thermal detectors are designed to com- mercial standards and offer an attractive appearance.

Operation

Each FST-951 Series detector uses one of the panel’s addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FST-951 Series offers fea- tures and performance that represent the latest in thermal detector technology.

Listings and Approvals

Listings and approvals below apply to the FST-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC Listing: S747
  • FM Approved
  • CSFM: 7270-0028:0502

FST-951 SPECIFICATIONS
Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5% to 3.5%
Size: 2.0" (5.3 cm) high; base determines diameter
B300-6: 6.1" (15.6 cm) diameter
B501: 4" (10.2 cm) diameter
For a complete list of detector bases see DN-60981
Shipping Weight: 3.4 oz. (95 g)
Operating Temperature range: FST-951, FST-951R Series: –4°F to 100°F (–20°C to 38°C
FST-951H Series: –4°F to 150°F (–20°C to 66°C)
Detector spacing: UL approved for 50 ft. (15.24 m) center-to-center, FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing
Relative Humidity: 10%-93% non-condensing.
Thermal Ratings: fixed-temperature set point 135 ° F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C)
Mounting: B300-6(A) flanged base, included
ELECTRICAL SPECIFICATIONS
Voltage Range: 15-32 volts DC peak.
Standby Current (max. avg.): 200μA @ 24 VDC (one communication every 5 seconds with LED enabled)
Max current: 4.5 mA @ 24 VDC (“ON”)
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad® PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW®) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> INTELLIGENT :    10 Items found.
B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

4098-9733
(6852)

TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Configure

$25.86 
4098-9714
(6845)

TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

4098-9601
(7076)

TYCO  4098-9601

Tyco Simplex 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

TYCO  4098-9757

Tyco Simplex 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

Configure

$61.78 
FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

4098-9756
(7075)

TYCO  4098-9756

Tyco Simplex 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.