Calibration Technologies Gg-nh3-0100 | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-NH3-0100

CALIBRATION TECHNOLOGIES GG-NH3-0100
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

GG-NH3-0100   
1,308.53

Gas Range
Enclosure
Relay Output
RM420 Relay Output

 In Stock  ]
4 Variants of base SKU
Key Features

  • Electronics completely potted to eliminate corrosion in harsh, wet environments
  • Ammonia specific electrochemical sensor technology. Absolutely no false alarms
  • No more special-order guesswork or added costs for heated or stainless enclosures
  • Industry standard linear 4/20 mA output
  • Corrosion, weather and chemical resistant polycarbonate sensor enclosure
  • Intelligent-design enclosure temperature control for improved cell life
  • Sensor designed to adapt to any harsh environment from -50°F to +140°F
  • Accurately monitor OSHA’s PEL, STEL and IDLH setpoints for personnel protection
  • Real-time continuous monitoring for early leak detection.
  • Just select the range: 0-100 ppm (standard), 0-250 ppm, 0-500 ppm or 0-1000 ppm
  • Any sensor can be field calibrated to any range listed

The GasGuard NH3 utilizes proven electrochemical sensor technology for fast and accurate leak detection. The standard detection range of the GasGuard NH3 provides real-time continuous monitoring of ammonia concentrations accurately down to 5 ppm, with no false alarms.

Every GasGuard NH3 sensor comes equipped with an intelligent internal temperature control designed to perform in the harshest of areas. The controlled environment provides optimum moisture control for extended cell life. The high-quality injection- molded polycarbonate enclosure offers excellent chemical corrosion protection and high impact resistance.

The GasGuard NH3 provides an industry standard linear 4/20 mA output signal compatible with most gas detection systems and PLCs. The output signal is not affected by drastic temperature variations such as washdowns, defrost cycles, etc.

Applications

  • Food Processing areas
  • Cold Storage
  • Compressor Rooms
  • Tank Rooms
  • Ventilation Ducts
  • Sea Vessels
  • Refrigeration Systems
  • Perimeter Monitoring
  • Pulp and Paper
  • Heat Treatment
  • Breweries
  • Refineries
  • Chemical Plants
Benefits

  • Versatile for any application
  • Easy to order
  • Low cost
  • Simple operation
  • Rugged and reliable

The standard GasGuard NH3 sensor is designed to work anywhere, and at a lower base-model price than most of our competition. With only one electrochemical sensor for any application, designing, ordering and maintaining your ammonia detection system is less hassle. We typically recommend a 0/100 ppm range for all personnel and product protection areas. Higher ranges (0/250, 0/500, 0/1000) are an option to suit your higher alarm setpoint areas such as Engine Rooms.

From -50°F blast cells, to +140°F engine rooms, to chemical washdowns of processing areas, the GasGuard NH3 is prepared to survive in just about any harsh industrial condition. Every circuit board is sealed forever in potting compound, protecting electronic components and copper tracing from corrosion. A specially vented chemical-resistant polycarbonate enclosure protects the sensor from accidental damage, weather and even direct hose-hits from clean-up crews. Stainless steel enclosures are available for applications which require them.

Specifications
DETECTION PRINCIPLE: Electrochemical
DETECTION METHOD: Diffusion
GASES: Ammonia (NH3)
RANGES: 0/100 ppm (standard)
0/250 ppm
0/500 ppm
0/1000 ppm
OUTPUT SIGNAL: Linear 4/20 mA (max input impedance: 700 Ohms)
POWER SUPPLY: +24 VDC, 350 mA
RESPONSE TIME: T50 = less than 20 seconds
T90 = less than 60 seconds
ACCURACY: +/- 5% of value, but dependant on calibration gas accuracy and time since last calibration
ZERO DRIFT: Less than 0.1% of full-scale per month, non-cumulative
SPAN DRIFT: Application dependant, but generally less than 3% per month
LINEARITY: +/- 1% of full-scale
REPEATABILITY: +/- 1% of full-scale
WIRING CONNECTIONS: 3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft.
ENCLOSURE: Injection-molded NEMA 4X polycarbonate
Hinged lid with captive screw. For non-classified areas.
TEMPERATURE RANGE: -50°F to +140°F (-46°C to +60°C)
HUMIDITY RANGE: 5% to 100% condensing
DIMENSIONS: 7.5” high x 6.5” wide x 3.75” deep
WEIGHT: 3 lbs
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    12 Items found.
CK-Cup-Hose
(2982)

CALIBRATION TECHNOLOGIES  CK-Cup-Hose

Standard cup, large cup & 3 ft hose



$35.89 
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
SHA-024-B
(2987)

CALIBRATION TECHNOLOGIES  SHA-024-B

CTI SHA-24 100dB Horn/Strobe 24 VDC. White body and blue lens. With weather proof mounting backbox. UL1638 approved.

Configure

$226.01 
SHA-120-B
(2988)

CALIBRATION TECHNOLOGIES  SHA-120-B

CTI SHA-120 99dB Horn/Strobe 120 VAC. White body and blue lens. With weather proof mounting backbox. UL Listed. NEMA 4X enclosure.

Configure

$253.17 
SHA-PY-120-B
(7080)

CALIBRATION TECHNOLOGIES  SHA-PY-120-B

CTI SHA-PY-120 Horn and Strobe. Weather-proof. 120 VAC. Two or three wire connection. High intensity 5 Joules Xenon flash and 8 selectable horn tones. Wall or ceiling mount. NEMA 4X. UL listed.

Configure

$329.80 
GG-NH3-RC
(2977)

CALIBRATION TECHNOLOGIES  GG-NH3-RC

Replacement electrochemical Ammonia (NH3) (0-100, 0-250, 0-300 and 0-500ppm) cell for the GasGuard-NH3.



$410.31 
GG-NH3-HR-RC
(2976)

CALIBRATION TECHNOLOGIES  GG-NH3-HR-RC

High Range electrochemical Ammonia (NH3) (0-1000 ppm) replacement cell for the GasGuard NH3, EC-F2 and EC-F9 units.



$410.31 
SL3-_24-R____-B
(6570)

CALIBRATION TECHNOLOGIES  SL3-24-R-B

CTI SL3 LED stack light with 105 dB buzzer. Up to 5 24VDC or 120VAC Flashing light modules (62 fpm). Polycarbonate Housing. 1/2" NPT conduit. IP66. NEMA 4X. UL listed.

Configure

$446.20 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> AMMONIA :    42 Items found.
GDS-IR2-1-301-0
(5829)

GDS  GDS-IR2-1-301-0

GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Page: 1 | 2 | 3 | All