Calibration Technologies Gg-h2s-50-exp | Hydrogen Sulfide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-H2S-50-EXP

CALIBRATION TECHNOLOGIES GG-H2S-50-EXP
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GG-H2S-50-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen Sulfide (H2S) 0-50 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

GG-H2S-50-EXP   
1,341.51

Relay Output
RM420 Relay Output

   In Stock  ]
Key Features
  • Explosion-proof enclosure for classified areas
  • Hydrogen sulfide selective electrochemical sensor technology
  • 0-50 ppm factory range
  • Electronics potted to eliminate internal corrosion
  • Industry standard 24VDC, linear 4-20 mA output
  • Operating temperature from -4°F to +122°F
  • Accurately monitor OSHA/NIOSH levels for personnel protection
  • No false alarms from interference gases
  • Real-time continuous monitoring for early leak detection

The GG-H2S-EXP is designed for detection of hydrogen sulfide vapors in hazardous areas. The standard detection range of 0-50 ppm provides real-time continuous monitoring of concentrations accurately down to 5 ppm with no false alarms.

The GG-H2S-EXP utilizes a proven hydrogen sulfide specifc electrochemical sensor for detecting poisonous H2S gas concentrations. No false alarms due to cross-sensitivities from other gases, and no false alarms from temperature or humidity fluctuations.

The GG-H2S-EXP provides an industry standard linear 4/20 mA output signal proportional to ppm concentration of hydrogen sulfide. Long sensor life with minimal span adjustment can be expected in most applications. The sensor is designed for simple calibration and the sensor head is easily field replaceable.

Applications
  • Sewer Gas Monitoring
  • Petroleum Refineries
  • Paper Mills
  • Tanneries
Benefits
  • Low cost explosion protection
  • No false alarms from interference gases
  • Simple operation & calibration

Hydrogen sulfide gas is slightly heavier than air and will tend to accumulate in low-lying areas in poorly ventilated spaces. For optimum personnel protection (representative concentration reading that an employee would be exposed to), mount the sensor at a height in the breathing zone of the employees. It would typically be no higher than 4 to 5 feet off the ground, which also allows easy access. As a general rule of thumb, try to mount sensors within 30 feet of potential H2S sources.

The GG-H2S-EXP is intended for horn/ strobe and ventilation activation, and is also useful for alarm outputs such as phone dialers and other alarm functions.

Typical sensor element life is 3 years, with minimal cross-sensitivity to other gases. Field replaceable sensor element keeps long term maintenance simple and low cost. Every circuit board is potted to completely eliminate corrosion to the electronic components and copper tracing on the circuit board. An explosion-proof aluminum enclosure houses the transmitter.

SPECIFICATIONS
Input Power:+24 VDC, 50 mA
Detection Principle:Electrochemical
Detection Method:Diffusion
Gases:Hydrogen Sulfide (H2S)
Range:0-50 ppm
Output Signal:Linear 4/20 mA (max input impedance: 700 Ohms)
Linearity:+/- 0.5% of full-scale
Repeatability:+/- 1% of full-scale
Response Time:T50 = less than 30 seconds
T90 = less than 120 seconds
Accuracy:+/- 5% of full-scale
Zero Drift:Less than 0.1% of full-scale per month, non- cumulative
Span Drift:Less than 3% per month
Temperature Range:-4°F to +122°F (-20°C to +50°C)
Humidity Range:5% to 95% non-condensing
Wiring Connections:3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft
Terminal Block Plugs: (Field Wiring)26-12 AWG, torque 4 lbs-in
Weight:3.75 lbs
Dimensions:6.75” high x 5.25” wide x 4.5” deep
Enclosure:Copper-free aluminum body, epoxy powder coat finish, neoprene gasket, for hazardous areas.
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
NEMA/EEMAC: 3, 4, 4X, 7BCD, 9EFG
UL Standard: 1203
CSA Standard: C22.2 No. 30
FM Classification No.: 3615
ATEX Certificate KEMA 02 ATEX 2265U
IEC Standards EN:60079-0, EN:60079-1, EN:60529
Warranty:2 years (including sensor element)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> HYDROGEN SULFIDE :    38 Items found.
2106B1400
(1451)

HONEYWELL  2106B1400

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) (0-20 ppm to 0-100 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109022/0010P-L0
(6914)

RC SYSTEMS  1100ALD-109022/0010P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
SPXCDULNHX
(663)

HONEYWELL  SPXCDULNHX

Honeywell XCD Sensepoint Gas Detector, Hydrogen Sulfide (H2S) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen sulfide (H2S) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. 0-50 ppm range. User-Selectable full scale range 10.0 to 100.0ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
965-015420-100
(5007)

DETCON  965-015420-100

Detcon MicroSafe TP-524D Smart gas detection Sensor designed to detect and monitor Hydrogen Sulfide (H2S) with range 0-100ppm using solid state metal oxide semiconductor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. ATEX, ISA and CE Approved. CSA and FM Approved for Class I, Division 1, Groups B, C, & D.

S3KUL2-XNXXSH1SS
(695)

HONEYWELL  S3KUL2-XNXXSH1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN SULFIDE (H2S) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-15ppm, 0-100ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,491.53 
100-0008-SS/100-0015-H2S
(4754)

ESP SAFETY  100-0008-SS/100-0015-H2S

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen Sulfide (H2S) 0-20, 0-50 or 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,536.30 
41001AL-0-1022/0005P/L0
(7167)

RC SYSTEMS  41001AL-0-1022/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1022/0005P/L0
(7122)

RC SYSTEMS  51001AL-0-1022/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN2 smart Electrochemical sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-240026-100G
(2132)

DETCON  961-240026-100G

Detcon DM-100-H2S Electrochemical Hydrogen Sulfide (H2S) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-242490-100
(6064)

DETCON  967-242490-100

Detcon DM-700-H2S Electrochemical Smart Hydrogen Sulfide (H2S) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNH2
(5104)

HONEYWELL  SPXCDULNH2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen Sulfide (H2S) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
967-011520-100
(4717)

DETCON  967-011520-100

Detcon TP-700 non-intrusive Smart Sensor for Hydrogen Sulfide (H2S) 0-100ppm using a solid state metal oxide semiconductor MOS technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

2100AL-0-9022/0010P/L0
(126)

RC SYSTEMS  2100AL-0-9022/0010P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
966-014520-100
(6101)

DETCON  966-014520-100

Detcon TP-624D Hydrogen Sulfide (H2S) 0-100ppm Smart Sensor with solid state metal oxide semiconductor technology. Includes MOS detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. ATEX and CSA approval for Class I, Division 1, Groups B, C & D.

XNXUTAENNNNN-XNXXSH1SS
(846)

HONEYWELL  XNXUTAENNNNN-XNXXSH1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Sulfide (H2S) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-15ppm, 0-100ppm

Configure

$1,963.60 
31001AL-0-9022/0010P/L0
(5784)

RC SYSTEMS  31001AL-0-9022/0010P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1(Explosion Proof).

Configure

$1,967.53 
6100AL1-0-1022/0005P
(7009)

RC SYSTEMS  6100AL1-0-1022/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with 'ST-44' smart transmitter and GEN2 smart Electrochemical sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
QTU-QRU-C-111
(6855)

SPECTREX  QTU-QRU-C-111

SPECTREX SafEye Quasar 950 open path gas detector and source with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$29,843.47 
Page: 1 | 2 | All