Calibration Technologies Gg-cl2-5-exp | Chlorine | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-CL2-5-EXP

CALIBRATION TECHNOLOGIES GG-CL2-5-EXP
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

GG-CL2-5-EXP   
1,341.51

Relay Output
RM420 Relay Output

   In Stock  ]
Key Features
  • Explosion-proof enclosure for classified areas
  • Chlorine selective electrochemical sensor technology
  • 0-5 ppm factory range
  • Electronics potted to eliminate internal corrosion
  • Industry standard 24VDC, linear 4-20 mA output
  • Operating temperature from -4°F to +122°F
  • Accurately monitor OSHA's TWA & STEL levels for personnel protection
  • No false alarms from interference gases
  • Real-time continuous monitoring for early leak detection

The GG-CL2-EXP is designed for detection of chlorine gas in hazardous areas. The standard detection range of 0-5 ppm provides real-time continuous monitoring of concentrations accurately down to 0.5 ppm with no false alarms.

The GG-CL2-EXP utilizes a proven chlorine specifc electrochemical sensor for detecting toxic chlorine gas concentrations. These toxic fumes can be from storage tanks, sanitizing or other sources. No false alarms due to crosssensitivities from other gases, and no false alarms from temperature or humidity fluctuations.

The GG-CL2-EXP provides an industry standard linear 4/20 mA output signal proportional to ppm concentration of chlorine. Long sensor life with minimal span adjustment can be expected in most applications. The sensor is designed for simple calibration and the sensor head is easily field replaceable.

Applications
  • Compressor Rooms
  • Tank Rooms
  • Cold Storage
  • Refrigeration System
  • Sea Vessels
  • Pulp and Paper
  • Heat Treatment
  • Chemical Plants
  • Breweries
Benefits
  • Low cost explosion protection
  • No false alarms from interference gases
  • Simple operation & calibration

Chlorine gas is more than twice as heavy as air and will tend to accumulate in low-lying areas in poorly ventilated rooms. For optimum personnel protection (representative concentration reading that an employee would be exposed to), mount the sensor at a height in the breathing zone of the employees. It would typically be no higher than 4 to 5 feet off the ground, which also allows easy access. As a general rule of thumb, try to mount sensors within 30 feet of potential CL2 leak sources.

The GG-CL2-EXP is intended for horn/ strobe and ventilation activation, and is also useful for alarm outputs such as phone dialers and other alarm functions.

Typical sensor element life is 3 years, with minimal cross-sensitivity to other gases. Field replaceable sensor element keeps long term maintenance simple and low cost. Every circuit board is potted to completely eliminate corrosion to the electronic components and copper tracing on the circuit board. An explosion-proof aluminum enclosure houses the transmitter.

SPECIFICATIONS
Input Power:+24 VDC, 50 mA
Detection Principle:Electrochemical
Detection Method:Diffusion
Gases:Chlorine (CL2)
Range:0-5 ppm
Output Signal:Linear 4/20 mA (max input impedance: 700 Ohms)
Linearity:+/- 0.5% of full-scale
Repeatability:+/- 1% of full-scale
Response Time:T50 = less than 30 seconds
T90 = less than 60 seconds
Accuracy:+/- 5% of full-scale
Zero Drift:Less than 0.1% of full-scale per month, non- cumulative
Span Drift:Less than 3% per month
Temperature Range:-4°F to +122°F (-20°C to +50°C)
Humidity Range:5% to 95% non-condensing
Wiring Connections:3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft
Terminal Block Plugs: (Field Wiring)26-12 AWG, torque 4 lbs-in
Weight:3.75 lbs
Dimensions:6.75” high x 5.25” wide x 4.5” deep
Enclosure:Copper-free aluminum body, epoxy powder coat finish, neoprene gasket, for hazardous areas.
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
NEMA/EEMAC: 3, 4, 4X, 7BCD, 9EFG
UL Standard: 1203
CSA Standard: C22.2 No. 30
FM Classification No.: 3615
ATEX Certificate KEMA 02 ATEX 2265U
IEC Standards EN:60079-0, EN:60079-1, EN:60529
Warranty:2 years (including sensor element)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> CHLORINE :    22 Items found.
31001AL-0-9014/01P/L0
(6889)

RC SYSTEMS  31001AL-0-9014/01P/L0

RC Systems SenSmart 3100 3 wire gas detector for Chlorine (Cl) 0-1ppm to 0-50ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,181.82 
6100AL1-0-1012/0050P
(7003)

RC SYSTEMS  6100AL1-0-1012/0050P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Chlorine (Cl2) 0-5 to 0-5000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,603.89 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.