Calibration Technologies Gg-co-200-exp | Carbon Monoxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-CO-200-EXP

CALIBRATION TECHNOLOGIES GG-CO-200-EXP
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GG-CO-EXP Explosion Proof Electrochemical Gas Sensor for Carbon Monoxide (CO) 0-200 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

GG-CO-200-EXP   
1,341.51

Relay Output
RM420 Relay Output

   In Stock  ]
Key Features
  • Explosion-proof enclosure for classified areas
  • Carbon Monoxide specific electrochemical sensor technology
  • 0-200 ppm factory range
  • Electronics potted to eliminate internal corrosion
  • Industry standard 24VDC, linear 4-20 mA output
  • Operating temperature from -4°F to +122°F
  • Accurately monitor CO levels for important action levels
  • No false alarms from interference gases
  • Real-time continuous monitoring for early CO detection

The GG-CO-EXP is designed for detection of carbon monoxide vapors in hazardous areas. The standard detection range of 0-200 ppm provides real-time continuous monitoring of concentrations accurately down to 20 ppm with no false alarms.

The GG-CO-EXP utilizes a proven hydrogen sulfide specifc electrochemical sensor for detecting poisonous CO gas concentrations. No false alarms due to cross-sensitivities from other gases, and no false alarms from temperature or humidity fluctuations.

The GG-CO-EXP provides an industry standard linear 4/20 mA output signal proportional to ppm concentration of carbon monoxide. Long sensor life with minimal span adjustment can be expected in most applications. The sensor is designed for simple calibration and the sensor head is easily field replaceable.

Applications
  • Food Processing areas
  • Tank Rooms
  • Parking Garages
  • Bottling Plants
  • Warehouses
  • Ventilation Ducts
  • Chemical Manufacturing
  • Air Quality Monitoring
  • Breweries
  • Modified Atmosphere Packaging
Benefits
  • Low cost explosion protection
  • No false alarms from interference gases
  • Simple operation & calibration

Carbon monoxide gas is approximately the same weight as air and will mix evenly with the air in all spaces. For personnel protection, mount the sensor at a height in the breathing zone of the employees. It would typically be 4 to 5 feet off the ground, which also allows easy access. As a general rule of thumb, try to mount sensors within 30 feet of potential CO sources.

The GG-CO-EXP is intended for horn/ strobe and ventilation activation, and is also useful for alarm outputs such as phone dialers and other alarm functions.

Typical sensor element life is 5+ years, with only a 20:1 cross-sensitivity to hydrogen. Field replaceable sensor element keeps long term mainte- nance simple and low cost. Every circuit board is potted to completely eliminate corrosion to the electronic components and copper tracing on the circuit board. An explosion-proof aluminum enclosure houses the transmitter.

SPECIFICATIONS
Input Power:+24 VDC, 50 mA
Detection Principle:Electrochemical
Detection Method:Diffusion
Gases:Carbon Monoxide (CO)
Range:0-200 ppm
Output Signal:Linear 4/20 mA (max input impedance: 700 Ohms)
Linearity:+/- 0.5% of full-scale
Repeatability:+/- 1% of full-scale
Response Time:T50 = less than 10 seconds
T90 = less than 20 seconds
Accuracy:+/- 5% of full-scale
Zero Drift:Less than 0.1% of full-scale per month, non- cumulative
Span Drift:Less than 2% per month
Temperature Range:-4°F to +122°F (-20°C to +50°C)
Humidity Range:5% to 95% non-condensing
Wiring Connections:3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft
Terminal Block Plugs: (Field Wiring)26-12 AWG, torque 4 lbs-in
Weight:3.75 lbs
Dimensions:6.75” high x 5.25” wide x 4.5” deep
Enclosure:Copper-free aluminum body, epoxy powder coat finish, neoprene gasket, for hazardous areas.
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
NEMA/EEMAC: 3, 4, 4X, 7BCD, 9EFG
UL Standard: 1203
CSA Standard: C22.2 No. 30
FM Classification No.: 3615
ATEX Certificate KEMA 02 ATEX 2265U
IEC Standards EN:60079-0, EN:60079-1, EN:60529
Warranty:2 years (including sensor element)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> CARBON MONOXIDE :    36 Items found.
OI-6000-EC-CO-X-X-O
(6835)

OTIS  OI-6000-EC-CO-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Carbon Monoxide (CO) 0-1000ppm. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-CO-200
(2963)

CALIBRATION TECHNOLOGIES  GG-CO-200

CTI GasGuard CO Carbon Monoxide Electrochemical Sensor (0-200 ppm) for gas leak detection in food processing areas, warehousestank rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,088.34 
2106B1405
(1453)

HONEYWELL  2106B1405

Honeywell Sieger Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) (0-100 to 0-500) ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109011/0100P-L0
(6909)

RC SYSTEMS  1100ALD-109011/0100P-L0

RC Systems SenSmart 1100 gas detector for Carbon Monoxide (CO) 0-100ppm to 0-5000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
100-0008-SS/100-0015-CO
(4751)

ESP SAFETY  100-0008-SS/100-0015-CO

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Carbon Monoxide (CO) 0-100, 0-500 or 0-1000ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
SPXCDULNCX
(664)

HONEYWELL  SPXCDULNCX

Honeywell XCD Sensepoint Gas Detector, Carbon Monoxide (CO) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for carbon monoxide (CO) gas hazards both indoors and outdoors. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 100 to 1,000ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,442.71 
S3KUL2-XNXXSC1SS
(686)

HONEYWELL  S3KUL2-XNXXSC1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CARBON MONOXIDE (CO) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-300ppm, user adjustable (100 to 999ppm, 100ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,497.56 
41001AL-0-1011/0050P/L0
(7159)

RC SYSTEMS  41001AL-0-1011/0050P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
961-440026-100G
(2131)

DETCON  961-440026-100G

Detcon DM-100-CO Electrochemical Carbon Monoxide (CO) 0-100ppm SensorAssembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

51001AL-0-1011/0050P/L0
(7124)

RC SYSTEMS  51001AL-0-1011/0050P/L0

RC Systems SenSmart 5100 3-wire gas detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-444490-0100
(6074)

DETCON  967-444490-0100

Detcon DM-700-CO Electrochemical Smart Carbon Monoxide (CO) 0-100 ppm/0-200 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNC2
(5096)

HONEYWELL  SPXCDULNC2

Honeywell Sensepoint XCD RTD Gas Detector for Carbon Monoxide (CO) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 200 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
2100AL-0-9011/0100P/L0
(117)

RC SYSTEMS  2100AL-0-9011/0100P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Carbon Monoxide (CO) 0-100ppm to 0-5000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9011/0100P/L0
(5780)

RC SYSTEMS  31001AL-0-9011/0100P/L0

RC Systems SenSmart 3100 3 wire gas detector for Carbon Monoxide (CO) 0-100ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSC1SS
(836)

HONEYWELL  XNXUTAENNNNN-XNXXSC1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Carbon Monoxide (CO) 0-300ppm, user adjustable (100 to 999ppm, 100ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1011/0050P
(7002)

RC SYSTEMS  6100AL1-0-1011/0050P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.