Industrial Scientific Tx1-4 | Nitrogen Dioxide | Gas Detectors (portable) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INDUSTRIAL SCIENTIFIC   TX1-4

INDUSTRIAL SCIENTIFIC TX1-4
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

TX1-4   
Please Email us your request for quote   

Soft nylon case

   2 Weeks  ]
  • DualSense ® Technology increases worker safety by using two sensors to detect the same gas
  • Guaranteed for Life TM with replaceable sensors and batteries that extends the life of the instrument
  • Optional AlarmAmp ® increases audible alarms to 110 dB
  • Acknowledgeable gas alerts

SPECIFICATIONS*
INSTRUMENT WARRANTYGuaranteed for Life TM . Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). CO and H2S sensors are warranted for three years. All other sensors are warranted for two years.
DISPLAYSegment liquid crystal display (LCD)
KEYPADTwo buttons
CASE MATERIALSCase top: Polycarbonate with a protective rubber overmold
Case bottom: Conductive polycarbonate
ALARMSThree strobe-emitting visual alarm LEDs (two red; one blue)
100 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm
DIMENSIONS99 x 51 x 35 mm (3.9 x 2.0 x 1.4 in)
WEIGHT126.0 g (4.4 oz)
TEMPERATURE RANGE-40 °C to 50 °C (-40 °F to 122 °F) **
HUMIDITY RANGE15% to 95% Non-condensing (continuous)
SENSORSCO, CO/H2 , H2S, NO2 , SO2 – Electrochemical sensor technology
SENSOR MEASURING RANGESCarbon Monoxide (CO): 0 to 1,000 ppm in 1 ppm increments
Carbon Monoxide (CO/H 2 low): 0 to 1,000 ppm in 1 ppm increments
Hydrogen Sulfide (H 2 S): 0.0 to 500.0 ppm in 0.1 ppm increments
Nitrogen Dioxide (NO 2 ): 0.0 to 150.0 ppm in 0.1 ppm increments
Sulfur Dioxide (SO 2 ): 0.0 to 150.0 ppm in 0.1 ppm increments
BATTERY3.6 V Primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to 2-year run time depending on operating conditions
DATA LOGGING3 months at 10-second intervals
EVENT LOGGING60 alarm events
CERTIFICATIONSINGRESS PROTECTION IP66/67
-40 °C to 50 °C (-40 °F to 122 °F)
/ ATEX: Ex ia I Ma; Ex ia IIC T4 Ga; Equipment Group/Category: I M1/II 1G
CSA : Cl I, Gr A-D, T4; Ex ia IIC T4
IECEx: Ex ia I Ma; Ex ia IIC T4 Ga
INMETRO: Ex ia I Ma; Ex ia IIC T4 Ga
UL (C-US): Cl I, Gr A-D, T4; Cl II, Gr E-G; Cl I, Zone 0, AEx ia IIC T4
-20 °C to 50 °C (-4 °F to 122 °F)
China Ex: Ex ia IIC T4 Ga
CMA: Ex ia I Ma; H 2 S, CO
EAC: PO Ex ia I X; 0 Ex iX IIC T4 X
KC: Ex ia IIC T4
* These specifications are based on performance averages and may vary by instrument.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
TX1-1
(5965)

INDUSTRIAL SCIENTIFIC  TX1-1

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO) 1-1000 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

TX1-2
(5966)

INDUSTRIAL SCIENTIFIC  TX1-2

Industrial Scientific Tango TX1 Gas Detector for Hydrogen Sulfide (H2S) 1-500 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

TX1-G
(5969)

INDUSTRIAL SCIENTIFIC  TX1-G

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO/H2 low): 1-1000 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

TX1-5
(5968)

INDUSTRIAL SCIENTIFIC  TX1-5

Industrial Scientific Tango TX1 Gas Detector for Sulfur Dioxide (SO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

> NITROGEN DIOXIDE :    28 Items found.
SPXCDULNNX
(666)

HONEYWELL  SPXCDULNNX

Honeywell XCD Sensepoint Gas Detector, Nitrogen Dioxide (NO2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for nitrogen dioxide (NO2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 10.0 to 50.0ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,763.64 
2100AL-0-9024/007P/L0
(237)

RC SYSTEMS  2100AL-0-9024/007P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,789.61 
S3KUL2-XNXXSN1SS
(696)

HONEYWELL  S3KUL2-XNXXSN1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring NITROGEN DIOXIDE (NO2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,789.84 
31001AL-0-9024/007P/L0
(5786)

RC SYSTEMS  31001AL-0-9024/007P/L0

RC Systems SenSmart 3100 3 wire gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,967.53 
967-646490-010
(6096)

DETCON  967-646490-010

Detcon DM-700-NO2 Electrochemical Smart Nitrogen Dioxide (NO2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSN1SS
(847)

HONEYWELL  XNXUTAENNNNN-XNXXSN1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitrogen Dioxide (NO2) 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,275.97 
6100AL1-0-1024/0005P
(7012)

RC SYSTEMS  6100AL1-0-1024/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class 1 Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
I-900G-NO2-0010
(7112)

INTERSCAN  I-900G-NO2-0010

Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Nitrogen Dioxide (NO2). Anodized aluminum enclosure. Includes rechargeable batteries.

Configure

$6,750.00 
Page: 1 | 2 | All
Cookie Notice